Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * CR123A batteries. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:

  1. Pressing the sabotage key three times (three times within 1.5 seconds), you enter the inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Philio 4-in-1 Sensor is a Z-Wave door/ window sensor, motion sensor, luminescence sensor and temperature sensor in one package. Thanks to this the PST02-1A can be uses as a security device or home automation device, e.g. to send an alarm when a motion is detected, turn the light on/ off automatically at night or to adjust the heater. The product consists of two elements - the detector and the magnet. The magnet is mounted on the moving part of the window or of the door. The other part is placed on the frame. Note: The illumination sensor does not work with Fibaro Homecenter 2 and Zipabox yet.

When included securely the device is able to accept secure commands and to send secure commands to other devices. The commands and the receiver of the commands sent out on single click and on double click of the rocker can be defined in configuration parameters and association groups.

Download high resolution images for Philio products.

Installation

Change battery:

If the device reports the battery message. The user should replace the battery. The battery type is CR123A, 3.0V. Please follow the steps below to open the front cover.

- Use a tool to press the 1-1 position to release the cover.
- Hold the front cover and pull it back
- Hold the front cover and pull upwards


Replace the new battery and replace the cover. Place the front cover base, and press down. Press the front cover.

Select the appropriate position:
- The recommended mounting height is 160cm.
- Do not let the device to the window or sunlight. For example, the heater or air conditioner.

Installation
  • Add the device to the Z-WaveTM network for the first time. First, make sure that the primary controller is in inclusion mode. And then turn on the device, just remove the insulation on the back of the device. The device will start the NWI (network wide inclusion) mode automatically. And it should be included in 5 seconds. The LED indicator will be on for one second.
  • Leave the control with the device in the first group. Any light switch that should be turned on when the device triggers, put in the second group.
  • There are two types of double coated tape in the accessory pack, one is thicker (hereafter referred to as A tape) and another is thinner (hereafter referred to as B tape), you can use the A tape for the test at the beginning. The correct way for tape installation is to hold it at the position below the tamper button. The thicker tape is not suitable when the tamper button is pressed, so the sensor will enter the test mode. You can test if you have chosen the optimal position.

After finishing the test and the determination, you can remove the A-tape and mount the sensor with the B-tape. The tamper button is pressed and the sensor is switched to normal mode.

Reset to factory default
  1. Press the tamper button four times within 1.5 seconds and do not release the tamper button at the 4th button and the LED will light up.
  2. After 3 seconds, the LED will turn off, then release the tamper button within 2 seconds. If this is successful, the LED will light up for one second. Otherwise the LED flashes once.
  3. IDs are excluded and all settings are reset to the factory settings.
 
Inclusion
  1. Pressing the sabotage key three times (three times within 1.5 seconds), you enter the inclusion mode.
Exclusion
  1. By pressing the sabotage key three times (three times within 1.5 seconds), you enter the exclusion mode.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Transmitting the message, such as triggered event, temperature, lighting, etc.
2 8 Light control, the device sends Basic Set CC to this group

Configuration Parameters

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light.
Size: 1 Byte, Default Value: 255

Setting Description
0 Disabled
1 - 100 Dimming value in %
254 Enabled

Parameter 3: PIR sensitivity

High sensitivity means that long distances can be detected, but if there is more noise in the environment, there may be more false triggering.
Size: 1 Byte, Default Value: 80

Setting Description
0 Disabled
1 - 99 1 is the lowest sensitivity ,99 is the highest sensitivity.

Parameter 4: Trigger limit for light

Setting the illumination threshold to turn on the light. When the event is triggered and the ambient illumination is lower than the threshold, the device turns on the light.
Size: 1 Byte, Default Value: 99

Setting Description
0 Disabled
1 - 99 1 means darkest 99 means lightest.

Parameter 5: Operating mode

The reserve bit is arbitrary, but without effect
Size: 1 Byte, Default Value: 0

Setting Description
1 Reserve.
2 1 means test mode, 0 means normal mode. Note: This bit only effect by DIP switch setting to Customer Mode, otherwise it decides by DIP switch setting to Test or Normal Mode.
4 Disabled Door/window function 1:Disabled 0:Enabled
8 Setting the temperature scale. 0: Fahrenheit, 1: Celsius
16 Disable the lighting report after the event is triggered. (1: Disable, 0: Enable)
32 Disable the temperature report after event triggering. (1: Disable, 0: Enable)
64 Reserve.
128 Reserve

Parameter 6: Multi-sensor function switching

Multisensor switching function - values can be added together 1+2=3
Size: 1 Byte, Default Value: 4

Setting Description
1 Deactivates the integrated magnetic contact, the brightness sensor controls the devices in group 2 (1: deactivate, 0: activate)
2 Disables the integrated PIR, the brightness sensor controls the devices in group 2 (1:Disabled; 0:Enabled).
4 Disable the magnetic integration of the PIR to turn on the lighting nodes in the assignment group 2. (1:Disable, 0:Enable)
8 If bit2 is 0 (Enable), are the device and the lighting in the same room? 0: In the same room (default), 1: In another room.
16 Disables the 5 seconds delay before the light is turned off, when closing the window or door (1: Disable, 0: Enable).
32 Disables automatic shutdown, light turns on only. (1: Disable, 0: Enable)
64 Reserve
128 Reserve

Parameter 7: User defined functions

Values can be added together 1+2=3
Size: 1 Byte, Default Value: 4

Setting Description
1 Reserve
2 Enable sending the movement OFF report. (0:Disable, 1:Enable)
4 Enable the PIR super sensitivity mode. (0:Disable, 1:Enable)
8 Deactivates the Basic Off area after closing the door (0: Deactivated; 1: Activated).
32 Disables the Multi CC command class in the Automatic Report (0: Disabled; 1: Enabled).
32 Disables the Multi CC command class in the Automatic Report (0: Disabled; 1: Enabled).
64 Disables the battery report (0: Disabled; 1: Enabled).
128 Reserve

Parameter 8: PIR recognition time

In normal mode, after the motion is detected, set the reacquisition time. 8 seconds per tick, default tick is 3 (24 seconds) .Set the appropriate value to prevent the trigger signal from being received too frequently. This can also save battery.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 127 Time 8 x value = time in seconds

Parameter 9: Switch-off time

This value becomes active after the lighting is switched on. Here the switch-off delay after detection of a movement is defined. 8 seconds per tick, default tick is 4 (32 seconds).
Size: 1 Byte, Default Value: 4

Setting Description
0 - 127 Delay 8 x value = time in seconds

Parameter 10: Automatic battery report

The interval time for the automatic reporting of the battery status. - The tick time can be set by configuration No. 20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Time in seconds

Parameter 11: Automatic report of the door/window status after time

The interval time for the automatic message of the door / window state. The tick time can be set by configuration No. 20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Time in seconds

Parameter 12: Automatic report brightness by time

The interval time for the automatic display of brightness. The tick time can be set by configuration no. 20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Time in seconds

Parameter 13: Automatic report by time for temperature

The interval time for the automatic display of the temperature. The tick time can be set by configuration no. 20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Time in seconds

Parameter 20: Automatic report tick interval

The interval time for automatic reporting of each tick. Setting this configuration will enable configuration No.10, No.11, No.12 and No.13. Attention: Setting to 0 means that all automatic reporting functions are disabled.
Size: 1 Byte, Default Value: 30

Setting Description
0 - 255 Tick interval

Parameter 21: Temperature difference report


Size: 1 Byte, Default Value: 1

Setting Description
0 Disabled
1 - 127 in °F

Parameter 22: Brightness difference report


Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 100 in %

Technical Data

Dimensions 95x28x35 mm
Weight 48 gr
Hardware Platform ZM5202
EAN 4713698570163
IP Class IP 20
Battery Type 1 * CR123A
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.02
Certification ID ZC10-14080012
Z-Wave Product Id 0x013C.0x0002.0x000C
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor