Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Once the controller is in inclusion mode, simply remove the battery isolation tab, OR insert the battery, OR press the small button on the back of the Motion Detector.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
For indoor use onlyOperating frequency: 908.42 MHzOperating range: Up to 100 feet (30.5 meters) line-of-sightOperating temperature: 0C to 49C, 32F to 120F (ambient temperature)Detection radius: 39 feet (see detection region diagram)Detection angle: 45 degrees in either direction from the sensors centerBattery type: 3V Lithium CR123ABattery life: approximately 3 years Passive Infrared (PIR) based technology
Reset to factory default |
To restore this sensor to factory default settings, follow the instructions for product exclusion which will reset the sensor upon completion of the process.Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion |
Once the controller is in inclusion mode, simply remove the battery isolation tab, OR insert the battery, OR press the small button on the back of the Motion Detector. |
Exclusion |
Once the controller is in exclusion mode, simply remove the battery isolation tab, OR insert the battery, OR press the small button on the back of the Motion Detector. |
NIF |
XXXNIF |
Wakeup |
If the sensor is asleep, simply remove the cover to wake up the sensor for configuration. |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
5 |
Z-Wave Plus Lifeline |
2 |
5 |
Used for the purpose of communicating directly to other Z-Wave products |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Z-Wave Version |
6.51.06 |
Certification ID |
ZC10-16020001 |
Z-Wave Product Id |
0x014A.0x0004.0x0001 |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |