Quickstart

This is a secure Z-Wave Device for XXXQFrequencyName. To run this device please insert fresh 1 * 9V Block batteries. To run this device please make sure the internal battery is fully charged.

 
1. Insert the battery into the smoke detector.
2. Press the button (3) for one second.
3. Phe safe inclusion starts while the LED flashes.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This product combines a certified smoke detector, which can also function individually, with a plug-in Z-Wave radio module. The smoke detector is certified by the VdS according to DIN EN 14604 and thus meets all legal requirements. The high-quality smoke chamber is made of stainless steel and special antistatic plastic.
 
A button on the instrument allows the smoke chamber, electronics and battery to be tested. In addition, automatic self-tests are integrated in the instrument to make a test with special aerosol unnecessary. The battery warning is emitted for at least 30 days and the warning indicator remains fully functional during this time.
 
The Z-Wave radio module makes it possible to transmit the smoke alarm to a central Z-Wave controller. The warning detector can still be used as a Z-Wave siren. An acoustic tone is switched on and off by radio. The radio module either uses the warning detector‘s built-in 9V battery or can alternatively be powered by an external 12V power supply unit - which can be installed in a flush-mounted box.
 
In accordance with the 3515 standard (smoke detectors with radio communication) this device will automatically forward all alarms to all other radio detectors in the Z-Wave network so that an alarm is transmitted throughout the house (must be activated via configuration parameter). This radio communication between the smoke detectors works automatically and without further configuration. The smoke detectors can communicate with each other and with the radio control centre via a specially encrypted protocol to prevent manipulation.
 

Installation

Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be installed. The installation guide complies with the norm DIN EN 14676.

  • Remove the bracket from the detector main unit by rotating it counter-clockwise.
  • Place the bracket where you are going to install the detector. In each of keyhole slots, draw a mark to locate plastic anchor and screw. Using a 3/16-inch (5mm) drill bit, drills two holes at the marks and insert plastic anchor, and attached the bracket by using the screws.
  • Open the battery compartment (1) to activate the battery, and then close the cover.
  • The optional external power supply will connect to the connector (5). The internal battery must stay inside the detector even when the external power supply is connected.
  • Mount the smoke detector to the mounting ring. Make sure the hooks of the detector are placed between the hook and the twist stopper (2) of the mounting base (arrows in image above). Then turn about 15 % clockwise. (Hint. If the detector hook is not placed right between the two mounting ring structures the detector can‘t be mounted to the ring).

Please follow the recommendations about amount as position of the sensor in your home as given above. Avoid to place the sensor into the angle of walls, prefer positions in the middle of the room.

Product Usage

If the smoke detector detects smoke, the siren will sound, the red LED will flash and a signal will be sent to the Z-Wave controller and all other smoke detectors in the network. If the battery is running low, the smoke detector will beep briefly several times a day for 30 days.
 
Note: All communication of the wireless module is carried out at the application level, provided that the device is included in "Secure" mode and all other communication partners also support secure transmission. If it is communicating with a device that does not support secure transmission, it will be switched to an unsecure connection for communication with that device. This process takes about 20 seconds and is performed the first time communication is established.
The siren can also be used for other alarms. Therefore it is displayed as a switch in the user interface of the controller. Switching on in the user interface starts the siren while switching off stops the siren. The generated alarm has the same effect as the real alarm.
 
Automatic radio meshing of the smoke detectors
Thanks to Z-Wave, the smoke detectors automatically communicate with each other in the same Z-Wave network (if the function is activated via the configuration parameters). In the event of an alarm (battery low or smoke), the corresponding detector sends encrypted messages (command alarm version 2 within a package of the command class Security) to all other detectors within radio range. These in turn send the signal to detectors that have not yet received the alarm signal. In this way, all detectors in the radio network are reached and can warn of the danger.
 
It is possible to deactivate the alarm on all smoke detectors to which the alarm is sent, but not on the triggering smoke detector. To do this, you must find and eliminate the cause of the alarm.
 
Note: For networking several smoke detectors, all of them must be taught-in once to a Z-Wave controller so that they are all in one network. This type of networking is not suitable for larger numbers (>3) of smoke detectors. Please use a logical link via the central controller and switch off automatic networking with configuration parameters 5 and 6.
 
Operation with power supply unit
 
The additionally available power supply unit supplies the Z-Wave wireless module with power. This significantly extends the battery life in the detector.
Please note that the detector itself will continue to function only with the battery. The siren function is also powered by the battery.

Battery:
The status of the battery is not displayed and sent to the controller for technical reasons. There is only a battery warning which is audible for at least 30 days by a short beep. 

Reset to factory default Press the button on the bottom of the device for at least 10 seconds
Inclusion
1. Insert the battery.
2. Press the button on the circuit board once.
Exclusion

1. Press the button on the circuit board once.

NIF

A simple click on the button (3) sends a NIF.

Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate Press the Button 2x short to confirm the update.
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 4 Lifeline
2 4 Alarm Reports
3 4 Switching Command when Alarm

Configuration Parameters

Parameter 1: Siren alarm sequence interval (only V.1.0)

The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds.
Size: 2 Byte, Default Value: 10

Setting Description
03 - 127 seconds

Parameter 2: Siren alarm tone length (only V.1.0)

The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval.
Size: 1 Byte, Default Value: 08

Setting Description
03 - 127 seconds

Parameter 3: Value of BASIC Set On-Command


Size: 1 Byte, Default Value: 99

Setting Description
00 - 99 Command Value

Parameter 4: Value of BASIC Set Off-Command


Size: 1 Byte, Default Value: 0

Setting Description
00 - 99 Command Value

Parameter 5: Status of automated meshing of smoke alarms

This smoke detector can automatically inform other smoke detectors of same type about smoke alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors
Size: 1 Byte, Default Value: 01

Setting Description
00 inactive
01 active (default)

Parameter 6: Status of automated meshing of battery alarms

This smoke detector can automatically inform other smoke detectors of same type about battery alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors.
Size: 1 Byte, Default Value: 01

Setting Description
00 inactive
01 active (default)

Technical Data

Dimensions 0.1060000x0.0350000x0.1060000 mm
Weight 140 gr
Hardware Platform ZM5202
EAN 0019962004001
IP Class IP 20
Battery Type 1 * 9V Block
Firmware Version 2.01
Z-Wave Version 04.05
Certification ID ZC10-15090004
Z-Wave Product Id 0x0154.0x0100.0x0201
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeZ-Wave Device