This is a
The Popp 10-Year Smoke Sensor consists of two parts: (1) a stand-alone smoke detector head that does not only fully comply to the European regulation EN15406 but to the much more advanced guideline vfdb 14-01. This means that the device ? among others ? ensures a 10 year battery life of the internal battery, is more resistive against mechanical stress and extreme temperature changes, and it is manufactured according to the advanced manufacturing standard UPC-2. (2) a wireless communication module, that has its own separate and replaceable battery. This module fits into the module bay of the smoke detector head and establishes a communication link to a central Z-Wave gateway reporting its battery status and of course any alarm condition. The module is certified according to the Z-Wave Plus guidelines. Additional functionality of this high end smoke detector includes periodic automated self test, dust compensation and special functions for sleeping rooms (no blinking) and easiness of use (large button for testing to be operated by a simple broom stick). Furthermore the device can be used also as an independent indoor siren within the Z-Wave network. Connected to different sensors via control center it will alarm in case of detected flood or burglary additionally to smoke or fire alarm. Yon don?t need to install another stand-alone siren.
Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be installed. The installation guide complies with the norm DIN EN 14676.
In case smoke is detected by the smoke detector the device will sound and the wireless module will issue a Z-Wave alarm command to the main controller and other associated devices. A low battery of the wireless module will be reported by the wireless module. Please note that the battery level of the main detector is not reported since this battery can?t be replaced anyway. The end-of-life indicator serves the same purpose. Outside Inside 3 Note: All communication of the wireless module is performed with application level security if the device was included securely and all communication partners support secure communication as well. In case a non-secure device is associated for switching on smoke alarm, the smoke detector will detect this and change its communication style with this very device to non-secure. This process happens one time and will take about 20 seconds. This delay will happen on first communication only.
Alarm Messages The device will issue the following (unsolicited) alarm messages:
Reset to factory default | To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable. |
Inclusion | 1. Remove the ceiling bracket.
2. Remove the Z-Wave board.
3. Insert the battery.
4. Re-insert the Z-Wave module.
5. Press the button for 3 seconds. |
Exclusion | 1. Remove the ceiling bracket.
2. Press the button once. |
NIF | A single click on the button will send out a NIF. |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | Once the firmware update process has started double click the Z-Wave button to confirm firmware update process. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 10 | Z-Wave Plus Lifeline |
2 | 10 | Alarm Reports. All devices in this group will receive Alarm notifications (Smoke , Battery Low, Tamper) |
3 | 10 | Switching Command. All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define the command value sent on alarm and alarm clearance. |
This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm occurs. Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 99 | BASIC Set Command |
255 | BASIC Set Command |
This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm is cleared. Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 99 | Basic Set Command |
255 | Basic Set Command |
Dimensions | 115x115x47 mm |
Weight | 202 gr |
Hardware Platform | ZM5202 |
EAN | 0019962009402 |
IP Class | IP 20 |
Battery Type | 1 * LS14250 |
Device Type | Notification Sensor |
Network Operation | Listening Sleeping Slave |
Firmware Version | 1.14 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16015002 |
Z-Wave Product Id | 0x0154.0x0004.0x0004 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |