This is a
The device consists of three pieces. The base (1) contains the gauge and a indicator to place it on a flat surface. The electronics block (2) is snapped into the base and a hood (3) covers the case and provides the funnel to collect the rain. Simple close-wise turning mounts and unmounts the hood. Before using the device the batteries need to be inserted into the electronics block. For this the device needs to be opened and the electronics block removed. Once the battery is installed the electronics block need to be placed into the base:
1. The flat side of the electronics block needs to be towards the gauge.
2. You need to push the two snap-in noses from the electronics block away to keep the block tight to the base and to avoid any water leckage.
The base can now be placed on a flat surface. If the surface is not flat - e.g. on soil? the device still must stand even to ensure correct measurement of the rain.
Note: Before the unit is ready for use, please remove the transport lock (small white cushions under the rocker)
Once the device is included and placed on the right spot it will report the rain level and alert on heavy rain. The max. precision of the rain meter is 3,5 mm rain per hour. Please not that the first measurement result right after start of rain may be inaccurate due to the measurement principle. The device counts full buckets of water and the filling level of the bucket prior to the start of rain is undetermined.
Maintenance:
Depending on the environment the device may get dirty over time. Please check the interior of the device frequency to remove old leafs and dirt that may cause incorrect measurements.
Reset to factory default | Push the button inside the device for at least 10 seconds |
Inclusion | 1. Open the hopper
2. Remove the transport lock
3. Open the battery compartment and insert the batteries.
4. Press the button once with a paper clip. |
Exclusion | 1. Open the hopper.
2. Open the battery compartment.
3. Press the button once with a paper clip. |
NIF | Push the Z-Wave button once |
Wakeup | Push the Z-Wave button once |
Protection | XXXProtection |
FirmwareUpdate | Push the Z-Wave button twice |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | Switching Command when Rain (> 0 mm/h). Basic Set Command is sent. |
3 | 5 | Heavy Rain detected. Basic Set Command is sent. |
This values shows the total count of rain from the moment of inclusion in mm water level. By writing this value this counter can be reset. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32000 | in mm |
This BASIC Set Command value is sent out into Association Group 2 when the device detects start of rain Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 99 | BASIC Set Value |
This BASIC Set Command value is sent out into Association Group 2 when the device detects stop of rain Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | BASIC Set Value |
This multiplier allows to adapt the display to certain controllers not being able to handle very low numbers. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 | 1 |
10 | 10 |
100 | 100 |
1000 | 1000 |
This threshold defines when a heavy rain condition is hit. In most countries this is defined as > 15 mm rain per hour. The default value however is to turn this function off. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | mm per hour |
This BASIC Set Command value is sent out into Association Group 3 when the device detects start of heavy rain Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 99 | Basic Set Value |
This BASIC Set Command value is sent out into Association Group 3 when the device detects stop of heavy rain Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | BASIC Set Value |
Dimensions | 132x132x139 mm |
Weight | 219 gr |
Hardware Platform | ZM5202 |
EAN | 4251295700168 |
IP Class | IP 55 |
Battery Type | 2 * AAA |
Device Type | Routing Multilevel Sensor |
Generic Device Class | Multilevel Sensor |
Specific Device Class | Routing Multilevel Sensor |
Firmware Version | 01.01 |
Z-Wave Version | 04.05 |
Certification ID | ZC10-17065642 |
Z-Wave Product Id | 0x0154.0x0004.0x0011 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |