Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * ER14250 1/2AA batteries. To run this device please make sure the internal battery is fully charged. Please insert the Z-Wave module including the battery into the smoke detector main device first. Pressing the "Z-Wave button" includes and excludes the device. Keeping the button pushed for 3 seconds will force secure inclusion.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This smoke detector will report smoke alarms wirelessly and securily into a Z-Wave network and is able to control other devices using associations The smoke detector?s sensor head is certified with the Q quality label, conforms DIN EN 14604 and satisfies all contemporary legal requirements. The High-End 10-years smoke detector offers a large test button conveniently accessible even with a broomstick when mounted on the sealing. The smoke chamber is monitored electronically to avoid any malfunction and wrong alerts. The device will also report its end of life to make sure it is getting replaced on time. Tampering a smoke detector by removing it from the mounting base will issue a wireless alarm command as well.

Installation

Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be installed. The installation guide complies with the norm DIN EN 14676.

  • The first step is to mount the mounting base on the desired place in the home using screws.
  • Remove the battery isolation strip from the wireless module. The yellow LED will start blinking.
  • Include the Smoke Sensor into your existing Z-Wave based Smart Home Network using the Z-Wave button.
  • Place the Smoke Detector on the mounting base and turn clockwise. Now the Smoke Detector is armed.
  • Battery Change: The battery of the wireless module will be empty much earlier than the 10 years soldered in battery of the smoke sensor. To replace the battery, remove the Smoke Detector, pull off the wireless module from the smoke sensor. Then you can replace the 1/2 AA battery and replug the wireless module.

Product Usage

In case smoke is detected by the smoke detector the device will sound and the wireless module will issue a Z-Wave alarm command to the main controller and BASIC commands other associated devices. The value of the BASIC message is defined in Configuration Parameters 3 and 4. The device will report the battery level of the module but not the level of the built-in battery of the detector head.  Once the device is placed on the mounting plate the tamper protection is active. Whenever the smoke detector head will be removed from the base for more than 4 seconds a tamper alarm will be sent wirelessly to the main controller. Note: All communication of the wireless module is performed with application-level security if the device was included securely and all communication partners support secure communication as well. In case a non-secure device is associated with switching on smoke alarms (in association group 2), the smoke detector will detect this and change the communication style to non-secure for this very device only. This process happens one time and will take about 20 seconds. This delay will happen on first communication only.

Alarm Messages
The device will issue the following (unsolicited) alarm messages:
  • Smoke Detected (this alarm message will be issued as well when the test button is pressed)
  • Low Battery Alarm (when the battery of the wireless modules goes low), indicated by yellow LED
  • Tamper Detected (ON, when the smoke detector head is removed from the base; OFF, when the detector head is mounted to the base)
  • End of Life (issued, when the Detector Main Head has reached its end of life after 10+ years.)

Reset to factory default To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults.
Inclusion Secure Inclusion: Push the button for 3 seconds
Unsecure Inclusion: Push the button for 1 seconds
Exclusion Push the button for 1 second
NIF A single click on the Z-Wave sends out a NIF.
Wakeup A double click on the Z-Wave button wakes up the device.
Protection XXXProtection
FirmwareUpdate Once the firmware update process has been started on the controller wakeup the device with a double click. The device will check the firmware request. When accepted the LED will blink to await confirmation on the device. Double click on the button to finally start firmware update.
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 10 Z-Wave Plus Lifeline
2 10 Switching Command. All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define the BASIC command sent.

Configuration Parameters

Parameter 3: Value of ON-Command

This value is sent as BASIC Set to Association Group 2 when an Smoke Alarm occurs.
Size: 1 Byte, Default Value: 99

Setting Description
0 - 99 Value
255 Value

Parameter 4: Value of Off-Command

This value is sent as BASIC Set to Association Group 2 when an Smoke Alarm is cleared.
Size: 1 Byte, Default Value: 99

Setting Description
0 - 99 Value
255 Value

Technical Data

Dimensions 115x115x47 mm
Weight 202 gr
Hardware Platform ZM5202
EAN 4251295700342
IP Class IP 20
Battery Type 1 * ER14250 1/2AA
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 3.05
Z-Wave Version 6.51.09
Z-Wave Product Id 0x0154.0x0004.0x0010
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor