Quickstart

This is a secure Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. Adding (Inclusion) and removing (Exclusion) of the device are confirmed by a triple click of the button. Fast blinking LED indicates the factory reset state. The device supports the Security S2 framework with unauthenticated network keys. Please follow the instructions on the central controller when including. The device also supports Smart Start. Please scan the QR code on the outlet cover of the device and your controller will add the device automatically when powered up.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Wall Plug Switch Outdoor can be placed between a wall outlet for plugs type F and electric devices, plugged in by a cord. It can switch all loads up to 3500 W. The plug switch is IP 44 rated and can, therefore, be used both in dry as well as humid environments in- and outdoor.
Switching is controlled by the local button or wirelessly. The use of the local button and the behavior on wireless commands can be configured using configuration parameters. When detached from the control of local leads the button on the device can be used to trigger scenes in a central gateway. A single click and double click are distinguished. 
The device is also measuring the mains voltage supply reporting mains voltage and mains frequency. Additionally, the power consumption of the attached load is monitored as well.
All metering values can be requested from the central controller and will be reported unsolicited if configured. 
 

Installation

The device can be plugged into every standard power outlet Type F. Thanks to IP44 rating this device can be used in wet environments such as bathrooms or basements and even outdoor. Do not stack the device!

Product Usage

The device is able to switch electric loads up to 3500 W and can be switched wirelessly or using the local button.  The connected load is measured and reported. Trigger values can define unsolicited power reports. The device includes a virtual circuit breaker. The configuration values 26-28 define the behavior of this function. Depending on the configuration parameter 4 the local button with either control the local load or sends scene activation commands to the central gateway.

Reset to factory default
Push and hold the button for 10seconds. After 5 seconds the LED on the button will blink fast.
Inclusion
1. Plug the device into the power outlet.
2. Press the button three times in succession.
Exclusion
1. plug the device into the power outlet.
2. Press the button three times in succession.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate Single Click the button to confirm the update
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline
2 5 Control other devices on single click of the button. BASIC command (on/off) is sent according to switching state of the load.

Configuration Parameters

Parameter 1: LED Operation Mode

Defines when the LED shall shine and how
Size: 1 Byte, Default Value: 1

Setting Description
0 LED off, only blinks on traffic
1 Defined by Parameter 21 and 22

Parameter 2: Auto Off

Defines if and after which time the device shall turn off without any user interaction
Size: 2 Byte, Default Value: 0

Setting Description
0 no auto off
1 - 65535 seconds

Parameter 3: Switching behavior when receiving wireless OFF


Size: 1 Byte, Default Value: 0

Setting Description
0 Switches off
1 Ignores Off command
2 Switches on
3 Switches on, when receiving off command and current state is off

Parameter 4: Button Mode

This parameter defines if the local button shall control (switch) the load or it is only used to send out scene control commands to the central controller.
Size: 1 Byte, Default Value: 0

Setting Description
0 Controls Load + Controls Scenes
1 Scene Control Only

Parameter 5: Status after Power Failure

Defines the switching status after a power failure or unplugging
Size: 1 Byte, Default Value: 1

Setting Description
0 Always off
1 Return to last switching state

Parameter 21: LED Color on OFF state

Defines the behavior of the LED when the load is switched off
Size: 1 Byte, Default Value: 0

Setting Description
0 Off
1 Red
2 Green

Parameter 22: LED Color on ON state

Defines the behavior of the LED when the load is switched on
Size: 1 Byte, Default Value: 2

Setting Description
0 Off
1 Red
2 Green

Parameter 23: Voltage Report Threshold

Report the voltage when the voltage has changed by more then X  * 1 V. When disabled the device will report every 10 minutes regardless of current voltage.
Size: 1 Byte, Default Value: 100

Setting Description
0 Disabled
1 - 250 Volt

Parameter 24: Current Reporting Threshold

Report the current when the current has changed by more then X *0,01 A. When disabled the device will report every 10 minutes regardless of current change.
Size: 1 Byte, Default Value: 10

Setting Description
0 Disabled
1 - 255 * 0,01 A

Parameter 25: Power Reporting Threshold

Report the power when the power  has changed by more then X Watt. When disabled the device will report every 10 minutes regardless of power consumption change.
Size: 1 Byte, Default Value: 50

Setting Description
0 Disabled
1 - 255 W

Parameter 26: Soft Circuit Breaker Threshold

When the power draw exceeds the value set in this parameter for a time set in parameter 28 the soft ciruit breaker will disconnect the load.
Size: 2 Byte, Default Value: 3600

Setting Description
0 Disabled
1 - 3600 W

Parameter 27: Soft Circuit Breaker Recovery Time

Once the soft circuit breaker tipps and the load is disconnected the load will be automatically reconneced after X seconds. When disabled the load must be repowered manually or with wireless command.
Size: 1 Byte, Default Value: 0

Setting Description
0 Never
1 - 255 sec.

Parameter 28: Soft Circuit Breaker Delay Time

This delay time defines how fast the soft circuit breaker wil react when the threshold power is exceeded. The power is cut off only if the power draw remains over the threshold level for the defines time.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 255 * 0,1 sec

Technical Data

Dimensions 114x59x92 mm mm
Weight 153 gr
Hardware Platform ZM5101
EAN 4251295700397
IP Class IP IP44
Voltage 230V
Load 3500 W
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 03.01
Z-Wave Version 6.01
Certification ID ZC10-18026015
Z-Wave Product Id 0x0154.0x0003.0x000a
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch