This is a
This device measures the three air quality parameters temperature, humidity and dew point an reports them to a central controller. Beside this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 15 minutes to measure the values and it will send unsolicited reports when values change. Additionally, the device will report all values on request.
The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone.
Open the POPP Mold Detector
To open the POPP Mold Detector, press the lock with your finger and pull the housing cover upwards.
Reset to factory default | Remove the cover, press the button for 5 seconds until it flashes green. Release the button and press the button again until the blinking stops. |
Inclusion | 1. Open the housing. 2. Remove the battery protection. 3. Press the tamper on the side of the appliance three times quickly. |
Exclusion | 1. Open the housing. 2. Press the tamper on the side of the appliance three times quickly. |
NIF | Tripple Click the tamper button |
Wakeup | A single click on the tamper button will wakeup the device. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | Temperature High Trigger |
3 | 5 | Temperature Low Trigger |
4 | 5 | Humidity High Trigger |
5 | 5 | Humidity Low Trigger |
This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active.
Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
1 - 100 | 1/10 degree |
0 | disabled |
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be active.
Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
1 - 20 | % |
0 | disabled |
This parameter defines the time interval to send an unsolicited report.
If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active.
Size: 2 Byte, Default Value: 43200
Setting | Description |
---|---|
900 - 65535 | Seconds |
0 | disabled |
This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2 Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 1000 | 1/10 degree |
0 | disabled |
This parameter defines a temperature. If the measured temperature dropps below this watermark a BASIC command is sent into Association Group 3 Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 1000 | 1/10 degree (0,1°C - 100°C) |
65336 - 65535 | 1/10 degree (-20,0°C - -0,1°C) |
0 | Disable |
This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
10 - 100 | % |
0 | disabled |
This parameter defines a relative humidity. If the measured temperature dropps below this relative humidity a BASIC command is sent into Association Group 5 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 90 | % |
0 | disabled |
This defines what BASIC command shall be sent out into association group 3 Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 2 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 5 Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 4 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Value |
Dimensions | 25x25x10 mm |
Weight | 11.73 gr |
Hardware Platform | ZM5101 |
EAN | 4251295701202 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 1 * 1/2 AA |
Device Type | Notification Sensor |
Generic Device Class | Notification Sensor |
Specific Device Class | Routing Notification Sensor |
Firmware Version | 01.01 |
Z-Wave Version | 06.02 |
Certification ID | ZC10-19026384 |
Z-Wave Product Id | 0x0154.0x0004.0x0014 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |