This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.

 Inclusion and Exclusion are confirmed by a tripple click of the button.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This is a switch plug that can be placed between a wall outlet Type E and electric devices, plugged in by cord. It can switch all electrical loads up to 3500 W. The device is IP 20 rated and can therefore only be used on dry environments. Switching is controlled wirelessly using Z-Wave or locally using a toggleing button. A blue LED indicates the switching status. An automatic "Off" function and programmable switching behavior make the device a very flexible tool for the inhouse lighting.

Installation

The plug can be plugged into every wall outlet for Plug-Type E. It is IP20 rated and can therefore only be used in dry environments. Do not locate the device facing direct sunlight, humid or dusty place. The suitable ambient temperature for the device is 0°C ~ 40°C. Plugs must not be stacked and operated.

Product Usage

The device is able to switch electric loads up to 3500 W and can be switched wirelessly or using the local button.

Local Operation
The local button allowes to switch the device. A short press on the button toggles the switch. If it is in on state the button turns off and respective in off state the button turns on.

LED Usage
The device has one blue LED used to indicate status information. The behavior of the blue LED can be configured:

  • It may show the switching state. This is the default option.
  • It may serve as night light. So it is on when the light is off.
  • It is deactivated.
  • It can be controlled wirelessly and used as an indicator for other advanced functions.

Automated Switch-Off Function
If activated the switch will turn off automatically after a defined time. This function is particularly useful if the switch is turned on using a motion detector of any other type of sensor. In this case it is possible to further define the reaction of the switch on certain signals sent from a sensor. This allowes a very flexible application of the plug switch in the house.

Reset to factory default XXXResetDescription
Inclusion

Inclusion and Exclusion are confirmed by a tripple click on the button.

Exclusion

Inclusion and Exclusion are confirmed by a tripple click on the button.

NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Send Reports on switch state change

Configuration Parameters

Parameter 1: LED mode

Set LED indication mode
Size: 1 Byte, Default Value: 01

Setting Description
00 Disabled
01 Show switch state
02 Night mode (inverted switch state)
03 Operated by Indicator Command Class

Parameter 2: Automatically switch off after

If not zero, automatically switch off after a user defined time
Size: 2 Byte, Default Value: 0000

Setting Description
0000 Disabled
0001 - ffff sec

Parameter 3: What to do on RF off command

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled).
Size: 1 Byte, Default Value: 00

Setting Description
00 Switch off
01 Ignore
02 Switch on
03 Switch on if load is off else switch off

Parameter 5: Restore switch state after power cycle

Defines if the switch should restore switch state to the last state prior to device power off (power cycle).
Size: 1 Byte, Default Value: 01

Setting Description
00 No, turn off
01 Yes

Technical Data

Dimensions 0.0590000x0.1010000x0.0750000 mm
Weight 130 gr
EAN 696859123627
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 01.00
Z-Wave Version 03.2a
Certification ID ZC08-13070028
Z-Wave Product Id 0115.1100.0001
Frequency Russia - 868.4MHz, 869.85MHz
Maximum transmission power 5 mW
RussiaOn/Off Power Switch