This is a
Tripple click the button on the device confirms the inclusion, exclusion and association. After plugging in it will stay in auto inclusion mode for 4 minutes.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This is a Plug-in switch, which can be placed between a wall outlet for British Standards plug and electric devices with a resistive load up to 3000W, plugged in by cord. In addition, this intelligent plug-in switch is able to detect the voltage, the power factor, the current amd measure the electric power taken by this load (in Wh) as well as meter the electrical energy consumed (in kWh). It will also detect a possible overload (3010 ~ 3300W) of the connected electrical device. When detecting an overload, the module is deactivated and the LED will flash for 30 seconds. In case the devices is used for metering only a special configuration option prevents the device from turning off the load.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
In the front casing there is an On/Off button with LED indicator, which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first powered, the LED flashes on and off alternately at a 2-seconds interval. It implies that it is not included in a Z-Wave network and has not been assigned a node ID.
Auto Inclusion
The auto inclusion starts when the switch is not included into a Z-Wave network and plugged into a wall outlet. Auto inclusion timeout is 4 minutes during the node information frame will be emitted once every 5 seconds. Unlike the normal inclusion it is not necessary pressing the On/Off button on the switch. If auto inclusion exceeds the timeout you have to include the device manually.
Note: Do not locate the switch facing direct sunlight, humid or dusty places. The suitable ambient temperature for the switch is 0°C - 40°C. Do not locate the switch near to combustible substances or any source of heat. After putting it into use, the casing of the switch will become a little bit warm.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Tripple Click the button on the device confirms inclusion and exclusion. After plugging in it will stay in auto inclusion mode for 4 minutes.
Tripple Click the button on the device confirms inclusion and exclusion. After plugging in it will stay in auto inclusion mode for 4 minutes.
Manual Operation
Remote Operation
Remote On/Off control of the switch is possible with any manufacturer"s Z-Wave controller. Further you can set associations to let your device controlled by other Z-Wave devices like sensors.
The switch is able to detect the current wattage (5 - 3150W) and overload wattage (3010 - 3300W) of connected ligths or appliances. When detecting overload state, the switch will be disabled and its On/off button will be locked and the LED will flash quickly. However unplug and reconnect the switch to reset its overload condition to normal status.
The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. To issue a NIF execute the following action:
Tripple click the button on the device sends out a Node Information Frame.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | When the power consumption of load vary over 5%, the device will send a Meter Report. When 'on' or 'off' state has been changed, it will send Binary Switch Report. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
If the setting is configured for 1hour (set value =720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 seconds Size: 2 Byte, Default Value: 02d0
Setting | Description |
---|
If the setting is configured for 1hour (set value =6), the device will report its Accumulated Power Consumption (KW/h) every hour to Z-Wave Controller. Unit: 10min Size: 2 Byte, Default Value: 0006
Setting | Description |
---|
This is a warning when the wattage of load over the preset threshold value, if the load wattage exceeds the setting value the device will send a warning alarm command to the controller. Size: 2 Byte, Default Value: 0bb8
Setting | Description |
---|
This is a warning when the KWh of load over the preset threshold value, if the Accumulated Power Consumption exceeds the setting value the device will send a warning alarm command to the controller. Size: 2 Byte, Default Value: 2710
Setting | Description |
---|
Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Switch Off |
01 | last Switch State |
02 | Switch On |
In case the plug is used for metering only this parameter prevents from switching off the load accidently. The over load protection remains active even in this state. Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Enabled |
Dimensions | 0.0580000x0.0950000x0.0610000 mm |
Weight | 109 gr |
EAN | 6968591236656 |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 01.01 |
Z-Wave Version | 03.29 |
Certification ID | ZC08-13020005 |
Z-Wave Product Id | 0154.0001.0001 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |