This is a
Tripple click the button on the device confirms the inclusion, exclusion and association. After plugging in it will stay in auto inclusion mode for 4 minutes.
This is a Plug-in switch, which can be placed between a wall outlet for British Standards plug and electric devices with a resistive load up to 3000W, plugged in by cord. In addition, this intelligent plug-in switch is able to detect the voltage, the power factor, the current amd measure the electric power taken by this load (in Wh) as well as meter the electrical energy consumed (in kWh). It will also detect a possible overload (3010 ~ 3300W) of the connected electrical device. When detecting an overload, the module is deactivated and the LED will flash for 30 seconds. In case the devices is used for metering only a special configuration option prevents the device from turning off the load.
In the front casing there is an On/Off button with LED indicator, which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first powered, the LED flashes on and off alternately at a 2-seconds interval. It implies that it is not included in a Z-Wave network and has not been assigned a node ID.
Auto Inclusion
The auto inclusion starts when the switch is not included into a Z-Wave network and plugged into a wall outlet. Auto inclusion timeout is 4 minutes during the node information frame will be emitted once every 5 seconds. Unlike the normal inclusion it is not necessary pressing the On/Off button on the switch. If auto inclusion exceeds the timeout you have to include the device manually.
Note: Do not locate the switch facing direct sunlight, humid or dusty places. The suitable ambient temperature for the switch is 0°C - 40°C. Do not locate the switch near to combustible substances or any source of heat. After putting it into use, the casing of the switch will become a little bit warm.
Manual Operation
Remote Operation
Remote On/Off control of the switch is possible with any manufacturer"s Z-Wave controller. Further you can set associations to let your device controlled by other Z-Wave devices like sensors.
The switch is able to detect the current wattage (5 - 3150W) and overload wattage (3010 - 3300W) of connected ligths or appliances. When detecting overload state, the switch will be disabled and its On/off button will be locked and the LED will flash quickly. However unplug and reconnect the switch to reset its overload condition to normal status.
Reset to factory default | XXXResetDescription |
Inclusion | Tripple Click the button on the device confirms inclusion and exclusion. After plugging in it will stay in auto inclusion mode for 4 minutes. |
Exclusion | Tripple Click the button on the device confirms inclusion and exclusion. After plugging in it will stay in auto inclusion mode for 4 minutes. |
NIF | Tripple click the button on the device sends out a Node Information Frame. |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | When the power consumption of load vary over 5%, the device will send a Meter Report. When 'on' or 'off' state has been changed, it will send Binary Switch Report. |
If the setting is configured for 1hour (set value =720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 seconds Size: 2 Byte, Default Value: 02d0
Setting | Description |
---|
If the setting is configured for 1hour (set value =6), the device will report its Accumulated Power Consumption (KW/h) every hour to Z-Wave Controller. Unit: 10min Size: 2 Byte, Default Value: 0006
Setting | Description |
---|
This is a warning when the wattage of load over the preset threshold value, if the load wattage exceeds the setting value the device will send a warning alarm command to the controller. Size: 2 Byte, Default Value: 0bb8
Setting | Description |
---|
This is a warning when the KWh of load over the preset threshold value, if the Accumulated Power Consumption exceeds the setting value the device will send a warning alarm command to the controller. Size: 2 Byte, Default Value: 2710
Setting | Description |
---|
Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Switch Off |
01 | last Switch State |
02 | Switch On |
In case the plug is used for metering only this parameter prevents from switching off the load accidently. The over load protection remains active even in this state. Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Enabled |
Dimensions | 0.0580000x0.0950000x0.0610000 mm |
Weight | 109 gr |
EAN | 6968591236656 |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 01.01 |
Z-Wave Version | 03.29 |
Certification ID | ZC08-13020005 |
Z-Wave Product Id | 0154.0001.0001 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |