This is a secure Siren for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The multiple sound siren PSE02 is a wireless siren, based on Z-Wave technology.It is theZ-Wave plus product, it support the security, OTA... Those newest features of the Z-Wave technology.Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.

Reset to factory default Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 pressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default.
Inclusion This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications.
Exclusion This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

1. Have Z-Wave Controller entered inclusion mode.2. Pressing tamper key three times within 1.5 secondsto enter the inclusion mode.3. After add successful, the LED will light ON 1 second

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

1. Have Z-Wave Controller entered exclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.Node ID has been excluded.

Configuration Parameters

Parameter 29: Disable Alarm

Disable the alarm function.1: Disable Alarm, 0: Enable Alarm.Caution: After the power up, this configuration always be 0.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 1: Disable Alarm, 0: Enable Alarm.

Parameter 31: Alarm Duration

Play alarm sound duration, 1 tick is 30 seconds. Default is 3 minutes, maximum is 63.5 minutes 0: means never auto stop.
Size: 1 Byte, Default Value: 6

Setting Description
0 - 127 Play alarm sound duration, 1 tick is 30seconds

Parameter 7: Customer Function

Customer function switch, using bit control.
Size: 1 Byte, Default Value: 0

Setting Description
16 Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.

Technical Data

Hardware Platform SD3502
Device Type Siren
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.15:01.12
Z-Wave Version 6.51.09
Certification ID ZC10-17035477
Z-Wave Product Id 0x013C.0x0004.0x000A
Supported Notification Types Home Security
Color White
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Siren