This is a
1. Have Z-WaveController entered add mode.2. Hold down the central key, then press the top-right key three times within 1.5 seconds to enter the add mode.3. After add successful, the device will wake to receive the setting command from Z-WaveController about 20 seconds.
The Remote PSR03-A is a simple control can control AV device through Z-Wave-to-IR extender, and it can also controls 2 lighting groups ON/OFF via basic set, based on Z-Wavetechnology.It is a Z-Wave plus product, it supports the security, OTA... Those newest features of theZ-Wavetechnology.Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
Reset to factory default | Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Hold down the central key, then press the top-right key four times within 1.5 seconds and do not release the top-right key in the 4 thpressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the keys. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are remove and all settings will reset to factory default. |
Inclusion | 1. Have Z-WaveController entered add mode.2. Hold down the central key, then press the top-right key three times within 1.5 seconds to enter the add mode.3. After add successful, the device will wake to receive the setting command from Z-WaveController about 20 seconds. |
Exclusion | 1. Have Z-Wave Controller entered remove mode.2. Hold down the central key, then press the top-right key three times within 1.5 seconds to enter the remove mode.Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the Wake Up Notification messagetothenetwork,andwake-up10secondsforreceivethe setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 4 | Z-Wave Plus Lifeline |
2 | 4 | Lighting group 1 |
3 | 4 | Lighting group 2 |
The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12.The value is in minutes. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report thebattery level. |
Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
-1 | -1 (0xFF) means turn the light on |
0 | Turn off the light |
1 - 99 | Set the light to level 1-99, 99 is full brightness |
Customer function switch, using bit control.Bit0: Switch AV control/Lighting group control. (0: AV control, 1: lighting group control) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | AV Control |
1 | Lighting Group Control |
Setting the BASIC command value to turn on the light in the association group 2. 0 means using the value of configuration 2 to set. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-1 | BASIC Command On (0xFF) |
0 | Use the value set by configuration parameter 2. |
1 - 99 | Setting the BASIC command value to turn on the light in the association group 2. |
Setting the BASIC command value to turn onthe light in the association group 3. 0 means using the value of configuration 2 toset. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-1 | BASIC Command On (0xFF) |
0 | Use the value set by configuration parameter 2. |
1 - 99 | Setting the BASIC command value to turn on the light in the association group 3. |
Hardware Platform | SD3502 |
Device Type | Remote Control - AV |
Network Operation | Portable Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15070018 |
Z-Wave Product Id | 0x013C.0x0008.0x0026 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |