Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
1. Have Z-Wave Controller entered inclusion mode.2. Rotate to area A and then press button three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This device is a multiple functions button switch. It is able toswitch the appliances on/off or adjust the percentage of dimmer.It can also work as a timer. The well designed wall bracket andmagnetic back let the switch can be fixed on the wall. This productcan be included and operated in any Z-Wavenetworkwith other Z-Wavecertified devices from other manufacturers and/or other applications.

Reset to factory default Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Rotate to area A and then press button four times within 1.5 seconds and do not release the button in the 4 thpressed, and the red LED will light ON.2. After the red LED goes out, release the button within 2 seconds.3. IDs are removed and all settings will reset to factory default.
Inclusion 1. Have Z-Wave Controller entered inclusion mode.2. Rotate to area A and then press button three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
Exclusion 1. Have Z-WaveController entered exclusion mode.2. Rotate to area A and then press button three times within 1.5 seconds toenter the exclusion mode. Node ID has been removed.
NIF XXXNIF
Wakeup After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the Wake Up Notification messagetothenetwork,andwake-up20secondsforreceivethe setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user wants to wake-up the device immediately, please rotate to area A and then press the button once. The device will wake-up 10 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline. The group 1 is for receiving the report message, like triggered event, temperature, humidity etc.
2 8 Lighting control group

Configuration Parameters

Parameter 1: Basic Set OFF level

Control the value represented by the left-side in area D.E.g. Setting this configuration to 0x0F means range of Command Basic Set value start from 0x0F
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Control the value represented by the left-side in area D.

Parameter 10: Auto Report Battery Time

The interval time for auto reporting the Battery level. 0 means turn off auto report battery. The default value is 12.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 The interval time for auto report the battery level.

Parameter 2: Basic Set ON level

Control the value represented by the right-side in area D.E.g. Setting this configuration to 0x1E means range of Command Basic Set value start from 0x1E
Size: 1 Byte, Default Value: 99

Setting Description
0 - 99 Control the value represented by the right-side in area D.

Parameter 25: Customer Function

Bit 0: Dimmer setting method. 0 : Auto send Command Basic Set after rotating.1 : Send Command Basic Set by touching key after rotatingBit 1: Disable buzzer in timer mode.0: Enable.1: Disable
Size: 1 Byte, Default Value: 0

Setting Description
1 Dimmer setting method. 0 : Auto send Command Basic Set after rotating. 1 : Send Command Basic Set by touching key after rotating
2 Disable buzzer in timer mode. 0: Enable. 1: Disable.

Parameter 26: Disable Scene Holding report

Send Central Scene Holding when the button is held.0x00: Enable.0x01: Disable.
Size: 1 Byte, Default Value: 0

Setting Description
1 Send Central Scene Holding when the button is held. 0x00: Enable. 0x01: Disable.

Technical Data

Hardware Platform SD3502
Device Type Wall Controller
Network Operation Portable Slave
Firmware Version HW: 1 FW: 1.09:01.06
Z-Wave Version 6.51.09
Certification ID ZC10-17105808
Z-Wave Product Id 0x013C.0x0009.0x0022
Frequency XXfrequency
Maximum transmission power XXantenna
BrazilWall Controller