Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
There are two tamper keys in the device, one is in the back side, another is in the front side.Both of themcan add,remove, reset or association from Z-Wave network.To add into a Z-Wave network: 1. Have Z-WaveController entered inclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The slim multisensor PST02 has PIR, door/window, temperature and illumination, 4 sensors function in one,based on Z-Wave technology.

Reset to factory default There are two tamper keys in the device, one is in the back side, another is in the front side.Both of themcan add,remove, reset or association from Z-Wave network.To reset the device: Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4thpressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default.
Inclusion There are two tamper keys in the device, one is in the back side, another is in the front side.Both of themcan add,remove, reset or association from Z-Wave network.To add into a Z-Wave network: 1. Have Z-WaveController entered inclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
Exclusion There are two tamper keys in the device, one is in the back side, another is in the front side.Both of themcan add,remove, reset or association from Z-Wave network.To remove the device from a Z-Wave network: 1. Have Z-WaveController entered exclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.Node ID has been excluded.
NIF XXXNIF
Wakeup There are two tamper keys in the device, one is in the back side, another is in the front side.Both of themcan add,remove, reset or association from Z-Wave network.Press any key once, the device will awake 10 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline
2 8 Using the u0022Basic Setu0022 for lighting control.

Configuration Parameters

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level. 0 means turn off auto report battery.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Auto Report Battery Time

Parameter 11: Auto Report Door/Window State Time

The interval time for auto report the door/window state. 0 means turn off auto report door/window state.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Auto Report Door/Window State Time

Parameter 12: Auto Report Illumination Time

The interval time for auto report the illumination. 0 means turn off auto report illumination.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Auto Report Illumination Time

Parameter 13: Auto Report Temperature Time

The interval time for auto report the temperature. 0 means turn off auto report temperature.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 Auto Report Temperature Time

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength.0 means turn off the light.
Size: 1 Byte, Default Value: 255

Setting Description
0 - 255 Basic Set Value

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13.Caution: Setting to 0 means turn off all auto report function.
Size: 1 Byte, Default Value: 30

Setting Description
0 - 255 Auto Report Tick Interval

Parameter 21: Temperature Differential Report

The temperature differential to report.0 means turn off this function. The unit is Fahrenheit.Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report.Enable this functionality will cause some issue please see the detail in the Temperature Report section.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 127 Temperature Differential Report

Parameter 22: Illumination Differential Report

The illumination differential to report.0 means turn off this function. The unit is percentage.Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the Illumination Report section.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Illumination Differential Report

Parameter 3: PIR Sensitivity

PIR sensitivity settings.0 means disable the PIR motion.1 means the lowest sensitivity,99 means the highest sensitivity.High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency.
Size: 1 Byte, Default Value: 80

Setting Description
0 - 99 PIR Level

Parameter 4: Light Threshold

Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light.0 means turn off illumination detected function. And never turn on the light.1 means darkest.99 means brightest.100 means turn off illumination detected function. And always turn on the light.Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.
Size: 1 Byte, Default Value: 99

Setting Description
0 - 100 Light Threshold

Parameter 5: Operation Mode

Operation mode. Using bit to control.Bit0: Reserve.Bit1: 1 means test mode, 0 means normal mode.Notice: This bit only effect by the DIP Switch setting to customer mode, otherwise it decides by DIP Switch setting to Test or Normal Mode.Bit2: Disable the door/window function. (1:Disable, 0:Enable)Bit3: Setting the temperature scale.0: Fahrenheit, 1:CelsiusBit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable)Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)Bit6: Reserve.Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable)Notice: The reserve bit is allowed any value, but no effect.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Operation Mode

Parameter 6: Mult-Sensor Function Switch

Multisensor function switch. Using bit to control.Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)Bit1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)Bit2: Disable magnetic integrate PIRto turn ON the lighting nodes in the association group 2. (Default is Disable) (1:Disable, 0:Enable)Bit3: When Bit2 is 0 (Enable), Are the device and the lighting in the same room?0: In the same room(Default),1: In the different room.Notice: If this bit is 1, it is recommended also set the Bit1 to 1, causethe PIR triggered, doesn't mean the people in that room.Bit4: Disable delay 5 seconds to turn off the light, when door/window closed.(1:Disable, 0:Enable)Bit5: Disable auto turn off the light, after door/window opened to turn on the light.(1:Disable, 0:Enable)Notice: If bit2 is zero, this setting is useless.Notice: If the configuration No.9 is zero, this setting is useless.Bit6: Reserve.Bit7: Reserve.Notice: The reserve bit is allowed any value, but no effect.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 255 Mult-Sensor Function Switch

Parameter 7: Customer Function

Customer function switch, using bit control.Bit0: Reserve.Bit1: Enable sending motion OFF report.(0:Disable, 1:Enable)Note: Depends on the Bit4,0: Report Notification CC, Type: 0x07, Event: 0xFE1: Sensor Binary Report, Type: 0x0C, Value: 0x00Bit2: Enable PIR super sensitivity mode.(0:Disable, 1:Enable)Bit3: Disable send out BASIC OFF after door closed.(1:Disable, 0:Enable)Bit4: Notification Type,0: Using Notification Report. 1: Using Sensor Binary Report.Bit5: Disable Multi CC in auto report.(1:Disable, 0:Enable)Bit6: Disable to report battery state when the device triggered.(1:Disable, 0:Enable)Bit7: Reserve.Notice: The reserve bit is allowed any value, but no effect.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 255 Customer Function

Parameter 8: PIR Re-Detect Interval Time

In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds).Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy.Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 127 PIR Re-Detect Interval Time

Parameter 9: Turn Off Light Time

After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds).0 means never send turn off light command.
Size: 1 Byte, Default Value: 4

Setting Description
0 - 127 Turn Off Light Time

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 01
Z-Wave Version 6.51.02
Certification ID ZC10-14080012
Z-Wave Product Id 0x013C.0x0002.0x000C
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor