This is a
AFit the two supplied AA batteries. The battery compartment is marked with a plus and minus sign. Ensure that each battery is correctly aligned. The SES 303 will now power up. On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds; refer to the ?Radio? section for details. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion/ Exclusion operation is successful.Step 1: On the Z-Wave controller, select Include if you are adding a device to the network or select Exclude if you are removing a device from the network. Check with the controller manufacturer?s manual.
Step 2: On the SES SES 303, press the button, hold and release after 1 second to send a request (Network Information Frame) to join the network.
The SES303 sensor is powered from 2XAA batteries and it is Z-Wave Plus certified. In addition to the standard functionality they also support one of the following optional configurations:
This unit is ideal for temperature and humidity measurement for smart central heating controls or any other similar application. Its user interface is straightforward and with a push button and LED indication on back side, one can easily include/exclude this to a Z-Wave network.
Keep the SES 303 in its sealed pack until all dust and debris have been cleared away prior to making connections. Remove the wall plate from the rear of the SES 303.
Choose the position where the unit is to be mounted (refer to the following layout). Avoid locations alongside or behind large metal surfaces that could interfere with the low power radio signals between the unit and the controller. The sensor should be mounted on an internal wall, approximately 1.5 metres (5 feet) above floor level and away from draughts, direct heat sources and sunlight. Make sure that there is sufficient space around the unit to allow easy access to the two retaining spring clips on the base of the wall plate. It may be necessary to move the sensor around to ensure good communication. Do not attempt to mount it on the wall until it has been included on the network.
The association process is applicable only after the device is included into network. Please note that some controllers can automatically associate. Always check with the manufacturer?s manual.
RF communication check after installation Press button for less than 1 second. The SES 303 will send temperature report of onboard sensor. Note: this feature only works when the device has been included in network and the nodes associated. Sending Node Information- Press and hold SES 303 button for more than 1 second and then release.
Reset to factory default | XXXResetDescription |
Inclusion | Fit the two supplied AA batteries. The battery compartment is marked with a plus and minus sign. Ensure that each battery is correctly aligned. The SES 303 will now power up.
On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds; refer to the ?Radio? section for details. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion/ Exclusion operation is successful. |
Exclusion | Fit the two supplied AA batteries. The battery compartment is marked with a plus and minus sign. Ensure that each battery is correctly aligned. The SES 303 will now power up.
On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds; refer to the ?Radio? section for details. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion/ Exclusion operation is successful. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 2 |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 125 | 0,1 - 12,5 °C |
130 - 255 | -0,1 - -12,5 °C |
Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 255 | Time in minutes |
Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 125 | 0,1 - 12,5 %RH |
130 - 255 | -0,1 - -12,5 %RH |
Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 255 | Time in minutes |
Dimensions | 0.0850000x0.0850000x0.0310000 mm |
Weight | 160 gr |
EAN | 5015914840098 |
Device Type | Routing Multilevel Sensor |
Generic Device Class | Multilevel Sensor |
Specific Device Class | Routing Multilevel Sensor |
Firmware Version | 01.00 |
Z-Wave Version | 03.5f |
Certification ID | ZC10-15010003 |
Z-Wave Product Id | 0059.000d.0003 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |