The device will fit into Water Meters from Sensus (http://sensusesaap.com/). To confirm inclusion and exclusion put a magnet on the flat side of the sensor for 3 seconds until the red LED is blinking. To send out a NIF or to wake up the device follow the same process.
SWM 301 is a battery-powered RF module using Z-Wave® technology for reporting water metering from SENSUS water meter (http://sensusesaap.com/). The RF module records the meter reading by backlash-free pick-up on the litre wheel of the meter register and transmits the data over the Z-Wave network either on a time or delta change. Choose the position where the unit is to be mounted, avoid locations alongside or behind large metal surfaces that could interfere with the low-power radio signals between the unit and the Controller. The unit contains a lithium battery which provide a 10 years battery life based on a 24hr reporting interval.
Just snap in the sensor in to the position beside the meter digit display. The device will fit into Water Meters from Sensus (http://sensusesaap.com/). It may also be applicable to other manufacturers meters but this is not supported by the manufacturer.
The meter readings are transmitted by wireless and can be read by any Z-Wave controller.
Reset to factory default | XXXResetDescription |
Inclusion | To confirm inclusion and exclusion put a magnet on the flat side of the sensor for 3 seconds until the red LED blinks. |
Exclusion | To confirm inclusion and exclusion put a magnet on the flat side of the sensor for 3 seconds until the red LED blinks. |
NIF | Put a magnet on the flat side of the sensor for 3 seconds until the red LED blinks. Water meter will then send NIF after 15 seconds. |
Wakeup | To wake up the device put a magnet on the flat side of the sensor for 3 seconds until the red LED blinks. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 2 | Nodes to receive unsolicited water meter reading |
2 | 2 | Nodes to receive unsolicited low battery warning report |
shows the actual counter of the sensor Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99999999 | Value- read only |
how often the meter reading is reported Size: 2 Byte, Default Value: 1440
Setting | Description |
---|---|
1 - 43200 | in minute |
defines the minimal change until a new meter value is reported Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 10000 | m³/Hr |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
00000000 - FFFFFFFF | Serial Number - read only |
in Format YYMMxxxx with YYY as year, MM as month and xxx as id Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
00000000 - FFFFFFFF | Serial Number - read only |
Weight | 40 gr |
Hardware Platform | ZM3102 |
EAN | 5015914845017 |
IP Class | IP 54 |
Battery Type | 1 * 3V Lithium |
Device Type | Smart Meter |
Firmware Version | 03.00 |
Z-Wave Version | 03.2a |
Certification ID | ZC08-13080017 |
Z-Wave Product Id | 0x0059.0x000f.0x0001 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |