Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
-Click [Add] icon in Z-Wave PC Controller Program-Press a Func_Button 1 time in SHP-SB100Z (Door Sensor)-If Inclusion Process is successful, LED is Blinking 3 times inSHP-SB100Z



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Detecting Window/Door openHarmonious design concept with home interior

Reset to factory default Device Factory Reset- Use this procedure only when he network primary controller is missingor otherwise inoperable-Press a Func_Button for 10 seconds in SHP-SB100Z-If Factory Reset Process is successful, LED is Blinking 1 time in SHP-SB100Z -Device Reset Locally notification is Transmitted
Inclusion -Click [Add] icon in Z-Wave PC Controller Program-Press a Func_Button 1 time in SHP-SB100Z (Door Sensor)-If Inclusion Process is successful, LED is Blinking 3 times inSHP-SB100Z
Exclusion -Click [Remove] icon in Z-Wave PC Controller Program-Press a Func_Button 3 times quickly in SHP-SB100Z-If Exclusion Process is successful, LED is Blinking 5 times in SHP-SB100Z
NIF XXXNIF
Wakeup - wake up when push a Func Button- wake up when door sensor is detected
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 -Lifeline between controller and SHP-SB100Z-Supported command classes : Battery report, Notification report, and Device Reset Locally notification

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-15060013
Z-Wave Product Id 0x022E.0x0004.0x0004
Frequency XXfrequency
Maximum transmission power XXantenna
South KoreaNotification Sensor