Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
-Click [Add] icon in Z-Wave PC Controller Program-Press a Func_Button 1 time in SHP-TB100Z (Smart Button)-If Inclusion Process is successful, LED is Blinking 3 times in SHP-TB100Z
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
Set up as door lock unlock or alarm panic button or to control other devices
Reset to factory default |
Please use this procedure only in the event that the network primary controller is missing or otherwise inoperablePress a Func_Button for 10 seconds in SHP-TB100Z-If Factory Reset Process is successful, LED is Blinking 1 time in SHP-TB100Z-Device Reset Locally notification is Transmitted |
Inclusion |
-Click [Add] icon in Z-Wave PC Controller Program-Press a Func_Button 1 time in SHP-TB100Z (Smart Button)-If Inclusion Process is successful, LED is Blinking 3 times in SHP-TB100Z |
Exclusion |
-Click [Remove] icon in Z-Wave PC Controller Program-Press a Func_Button 3 times quickly in SHP-TB100Z-If Exclusion Process is successful, LED is Blinking 5 times in SHP-TB100Z |
NIF |
XXXNIF |
Wakeup |
- press a Func_Button |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
5 |
-Lifeline between controller and SHP-TB100Z-Supported command classes: Battery report, Notification report, and Device Reset Locally notification-Maximum supported nodes are 5 |
Technical Data
Hardware Platform |
ZM5101 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
01 |
Z-Wave Version |
6.51.06 |
Certification ID |
ZC10-15060018 |
Z-Wave Product Id |
0x022E.0x0003.0x0003 |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |