This is a
Are you toying with the idea of fitting a motion detector to your building? The infrared controlled IS 140-2 motion detector gives you all the benefits of a modern detector. Needless to say, we always use the very latest technology for our bestsellers too. For instance, we have given the product in its current generation even more class: larger adjustment angle, even longer reach and even better detection performance. Treat your home to intelligent sensor technology.
Electrical installation
Reset to factory default | 1) Turn the device‘s control dial (E) to "Set" and move it to "Reset" within 5 seconds. 2) The status LED (F) briefly flashes to show that the light has been reset. 3) The device is now no longer included in the Z-Wave system and has been returned to factory settings. |
Inclusion | To put the device into inclusion mode, turn the device‘s control dial (E) to "Set" and back to "0" within 5 seconds. |
Exclusion | Exclusion = Remove To start the motion detector‘s exclusion mode, turn the device‘s control dial (E) to "Set" and back to "0" within 5 seconds. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
2 | 5 | Relay Switch |
3 | 5 | Motin begin/end - Relay Switch |
4 | 16 | Ambient light- Multilevel Sensor Report |
Duration of light after motion detection. Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
5 - 900 | seconds |
Light threshold [ lx ]Value can be controlled via potentiometer - potentiometer value isused as the default value and any potentiometer movement rewritesthe current setting. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
0 | run Learn ambient light sequence (the level is set automatically) |
2 - 1999 | lux |
2000 | 2000 - is used as daylight ( always night mode) |
Motion Sensor (PIR) Sensitivity [%]Value can be controlled via potentiometer - potentiometer value isused as the default value and any potentiometer movement rewritesthe current setting Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
2 - 100 | % |
Use External Ambient Light ValueWhen GLOBAL_LIGHT mode is ON - device overrides its own lightsensor values and uses Light report values from any Z-Wave lightsensor instead - this has to be configured appropriately to send lightautomatically.If the last remote light level value is older than 30 minutes, the internallight value is used again until the next external value is received. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | OFF function |
1 | ON function |
Can disable sensor controllu201cStupidu201d mode (bit 2 = 1): - has higher priority then slave mode. - lamp is permanently on (usefull for simple power wall switch controlling).Slave mode ( bit 0 = 1 ):- only if included in Z-Wave network- usefull for controlling via third-party sensor- relay is directly controlled via Z-Wave, internal sensors are not used for controlling it.Central unit checking ( bit 1 = 1 ):( usefull especialy for controlling via gateway ) When Slave bit is 0:- lamp signalises fail of lifeline connection ( if this bit is zero fail of lifeline connection is not signalised ) When slave bit is 1:- device checks presence of Z-Wave device in lifeline group ( gateway ). If it is not present for 2 minutes ( testing repeatedly every 30 seconds ) device switches to normal mode in the same way as after the end of local disabled mode ( ON_BEHAVIOUR )- The device checks every 1 minute for recovery of Lifeline connection.- if no lifeline specified - it works in normal modeBe careful with this option, lamp stops using itu2019s own motion sensor in Slave and Stupid mode. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Normal mode |
1 | Slave mode without gateway checking |
2 | Normal mode with lifeline error signalisation |
3 | Slave mode with gateway checking |
4 | Stupid mode - lamp permanetly on |
Behaviour after BASIC OFF ( and similar commands ).If a transition ( even with zero change ) with a non-default duration isto be processed, the transition cannot be interrupted by any motionevent in any case.for values 1-209 - Lamp is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Lamp is switched off and remains so until any new motion event (local or remote) is received. |
1 - 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution |
101 - 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution |
201 - 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution |
255 | Lamp is switched off for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation |
Behaviour after BASIC ON (and similar commands).If a transition (even with zero change) with a non-default duration is to be processed, the transition cannot be interrupted by any motion event in any case.for values 1-209 - Lamp is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. |
1 - 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution |
101 - 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution |
201 - 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution |
255 | Lamp is switched on for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation. |
Time limit to stop waiting for motion after timeout of ON_BEHAVIOURor OFF_ON_BEHAVIOUR ( 0-209 ) to prevent staying ON forever whenis no motion. Size: 2 Byte, Default Value: 204
Setting | Description |
---|---|
0 | o additional waiting for motion. |
1 - 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution |
101 - 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution |
201 - 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution |
255 | Never stop waiting before motion. |
Behaviour after after a rapid sequence of BASIC ON and BASIC OFF commands.The intention is to use a much longer timeout value than the time after a single ON command which should then be followed by a short timeout value.The behaviour is almost the same as for parameter 10 (OFF_LOCAL_DISABLE) for values 1-209 - Lamp is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received. Size: 2 Byte, Default Value: 204
Setting | Description |
---|---|
0 | Lamp is switched off and remains so until any new motion event (local or remote) is received. |
1 - 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution |
101 - 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution |
201 - 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution |
255 | device ignores ON - OFF sequence and uses OFF behavior |
Behaviour after after a rapid sequence of BASIC OFF and BASIC ONcommands.The intention is to use a much longer timeout value than the time aftera single OFF command which should then be followed by a shorttimeout value.The behaviour is amost the same as for parameter 11for values 1-209 - Lamp is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation. Size: 2 Byte, Default Value: 204
Setting | Description |
---|---|
0 | Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice - during the day, this mode cannot be ended remotely due to motion events not being transmitted - only via local motion sensor if enabled. |
1 - 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution. |
101 - 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution |
201 - 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution |
255 | device ignores OFF - ON sequence and uses ON behaviour |
Time in [ 100 miliseconds ] of maximum delay between BASIC ONand BASIC OFF ( and vice versa ) to consider this as a sequence. It istypically 1 second, but can be exceptionally longer due to retransmissionsand overload - in this case, a longer interval can be allowed ( upto 5 seconds ). Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
10 - 50 | tenth of second |
Motion disable timeout after BASIC SET to motion endpoint when theinternal motion sensor is not used for evaluating the behaviour of thelamp and groups 2 and 3. Events are, however, still transmitted to theLifeline, and the lamp can be controlled via remote motion sensors.for values 1-209 - Internal motion sensor is disabled for specified timeout after BASIC SET 0x00 to Motion endpoint. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still enabled |
1 - 100 | timeout: 1 second (1) to 100 seconds (100) in 1-second resolution |
101 - 200 | timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution |
201 - 209 | timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution |
255 | BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to relay endpoint, motion sensor still disabled |
Dimensions | 86 x 70 x 95 mm |
Weight | 170 gr |
Hardware Platform | ZM5202 |
EAN | 4007841029807 |
IP Class | IP 54 |
Voltage | 230 V |
Load | 100 W |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Firmware Version | 00.26 |
Z-Wave Version | 04.26 |
Certification ID | ZC10-17045540 |
Z-Wave Product Id | 0x0271.0x0002.0x1a72 |
Supported Notification Types | Home SecuritySystem |
IP (Ingress Protection) Rated | ok |
Firmware Updatable | Updatable by Consumer by RF |
Neutral Wire Required | ok |
Sensors | LuminanceMotion/No Motion (Binary) |
Outdoor Use | ok |
Electric Load Type | |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |