This is a
Reset to factory default | To set the sensor to "Reset", press the button three times in rapid succession and then press it once for several seconds. |
Inclusion | Press the button three times in rapid succession to put the sensor into inclusion mode. |
Exclusion | To put the sensor into exclusion mode, press the button three times in rapid succession. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
2 | 16 | On/Off control |
3 | 16 | Notification Report |
4 | 16 | Ambient light |
5 | 16 | Button on/off |
6 | 16 | Button scene |
7 | 16 | Button dim |
Duration of light after motion detection. Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
5 - 900 | Time in s |
Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 | Run Learn ambient light sequence. |
2 - 2000 | Threshold in lx |
Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
2 - 100 | in % |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Function is off. |
5 - 120 | in min. |
When GLOBAL_LIGHT mode is ON – device overrides its own light sensor values and uses Light report values from any Z-Wave light sensor instead – this has to be configured appropriately to send light automatically.If the last remote light level value is older than 30 minutes, the internal light value is used again until the next external value is received. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Stupid mode ( bit 2 = 1 ):- has higher priority then slave mode.- LED is permanently on ( for simple power wall switch controlling ).
Slave mode ( bit 0 = 1 ):- only if included in Z-Wave network- useful for controlling via third-party sensor- LED is directly controlled via Z-Wave, internal sensors are not used for controlling it Central unit checking ( bit 1 = 1 ): ( useful especially for controlling via gateway )
When slave bit is 0: - device signalises fail of lifeline connection ( if this bit is zero, fail of lifeline connection is not signalised )When slave bit is 1: - device checks presence of Z-Wave device in lifeline group ( gateway ). If it is not present for 2 minutes ( testing repeatedly every 30 seconds ) device switches to normal mode in the same way as after the end of local disabled mode(ON_BEHAVIOUR)- the device checks every 1 minute for recovery of Lifeline connection.- if no lifeline specified - it works in normal mode
Be careful with this option, device stops using its own motion sensor in Slave and Stupid mode.
Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Slave mode |
1 | Central unit checking in slave mode |
2 | Stupid mode |
Behaviour after BASIC OFF ( and similar commands ). If a transition ( even with zero change ) with a non-default duration is to be processed, the transition cannot be interrupted by any motion event in any motion event in any case. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 | LED is switched off and remains so until any new motion event ( local or remote ) is received. |
1 - 209 | LED is switched off and remains so until after a specified timeout once a new motion event ( local or remote ) is received. Timeout: 1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in 1-second resolution 101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) 1-minute resolution 201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour resolution |
255 | LED is switched off for TIME ( cfg 1 ). It does not wait for a motion event and works normally via current motion evaluation. |
Behaviour after BASIC ON ( and similar commands ). If a transition ( even with zero change ) with a non-default duration is to be processed, the transition cannot be interrupted by any motion event in any case. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 | LED is switched on and remains so until any new motion event ( local or remote ) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled. |
1 - 209 | LED is switched off and remains so until after a specified timeout once a new motion event ( local or remote ) is received. Timeout: 1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in 1-second resolution 101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) 1-minute resolution 201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour resolution Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled. |
255 | LED is switched off for TIME ( cfg 1 ). It does not wait for a motion event and works normally via current motion evaluation. |
Time limit to stop waiting for motion after timeout of ON_BEHAVIOUR or OFF_ON_ BEHAVIOUR ( 0-209 ) to prevent staying ON forever when there is no motion. Size: 2 Byte, Default Value: 204
Setting | Description |
---|---|
0 | No additional waiting for motion. |
1 - 209 | 1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in 1-second resolution 101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) in 1-minute resolution 201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour resolution |
255 | Never stop waiting for motion. |
Behaviour after a rapid sequence of BASIC ON and BASIC OFF commands. The intention is to use a much longer timeout value than the time after a single ON command which should then be followed by a short timeout value. Size: 2 Byte, Default Value: 204
Setting | Description |
---|---|
0 | LED is switched off and remains so until any new motion event ( local or remote ) is received. |
1 - 209 | LED is switched off and remains so until after a specified timeout once a new motion event ( local or remote ) is received. Timeout: 1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in 1-second resolution 101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) 1-minute resolution 201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour resolution |
255 | Device ignores ON - OFF sequence and uses OFF behavior |
Behaviour after a rapid sequence of BASIC OFF and BASIC ON commands. The intention is to use a much longer timeout value than the time after a single OFF command which should then be followed by a short timeout value. Size: 2 Byte, Default Value: 204
Setting | Description |
---|---|
0 | LED is switched on and remains so until any new motion event ( local or remote ) is received. It then works normally via current motion evaluation. |
1 - 209 | LED is switched off and remains so until after a specified timeout once a new motion event ( local or remote ) is received. Timeout: 1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in 1-second resolution 101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) 1-minute resolution 201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour resolution |
255 | Device ignores OFF - ON sequence and uses ON behaviour. |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
10 - 50 | Time in 100ms |
Motion disable timeout after BASIC SET to motion endpoint when the internal motion sensor is not used for evaluating the behaviour of the LED and groups 2 and 3. Events are, however, still transmitted to the Lifeline, and the device can be controlled via remote motion sensors. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to LED endpoint, motion sensor still enabled |
1 - 209 | Internal motion sensor is disabled for specified timeout after BASIC SET 0x00 to Motion sensor endpoint. BASIC to root is mapped to Motion sensor endpoint. ( SPIR ) Timeout: 1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in 1-second resolution 101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) in 1-minute resolution 201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour resolution |
255 | BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to LED endpoint, motion sensor still disabled |
Dim increase ( bit 0 ):- long press of button does dim decreasing ( 0 = default )- long press of button does dim increasing ( 1 )
Scene switch ( bit 1 ):- short press of button does toggle – on/off ( 0 = default )- short press of button does scene switch ( 1 )
Standalone behaviour ( bit 2 ):- using legacy sensor deactivity after button press ( 0 = default )- using cfg 10-14 sensor deactivity after button press ( 1 )
Network behaviour ( bit 3 ):- using legacy sensor deactivity after button press ( 0 )- using cfg 10-14 sensor deactivity after button press ( 1 = default )
Dim disable ( bit 4 ):- dim events ( long press ) are used ( 0 = default )- dim events ( long press ) are ignored ( 1 )
legacy sensor deactivity behaviour does this:- Pressing push button when LED is OFF: LED will switch on as long as there is movement and the delay time runs of- Pressing push button when LED is ON: LED will switch off as long as there is movement ans the delay time runs of ( invers logic ).
cfg 10-14 sensor deactivity behaviour uses behaviour specified in parameters 10-14 ( the same behaviour as pressing of external switch using BASIC ON/OFF functions )
Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 | Dim increase |
2 | Scene switch |
4 | Standalone behaviour |
8 | Network behaviour |
16 | Dim disable |
Parameters 18 specifies scene numbers ( from 1 to number ) to be switched by toggle button. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | menas – do not useany. |
1 - 127 | Scene ID |
In legacy button mode function this timeout is used to cancel motion sensor inactivity mode after motion end ( both for on and off state of LED ). Size: 2 Byte, Default Value: 103
Setting | Description |
---|
Dimensions | 55 x 55 x 57 mm |
Weight | 140 gr |
Hardware Platform | ZM5101 |
EAN | 4007841035402 |
IP Class | IP 20 |
Voltage | 230 |
Firmware Version | 01.80 |
Z-Wave Version | 05.03 |
Certification ID | ZC10-18076193 |
Z-Wave Product Id | 0x0271.0x0002.0x19fb |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |