Quickstart

This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Pressing On/Off button three times within 1.5seconds will enter inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The wall mounted switch is a component of the lighting control system. This wall mounted switch is designed to work with other Z-Wave enabled devices. Z-Wave nodes of other types can be added to the system and act as repeaters if they support this function of repeating the signal received to other modules in the  system. As part of a Z-Wave network, this switch will also act as a wireless repeater to insure that commands intended for another device in the network are received. This is useful when the device would otherwise be out of the radio range of the wireless controller. There are no field repairable assemblies on this unit.

Installation


Reset to factory default
  1. Pressing On/Off button three times within 1.5 seconds will enter inclusion mode.
  2. Within 5 second,press On/Off button again for 1 seconds until LED is off
  3. IDs are excluded.
Inclusion Pressing On/Off button three times within 1.5seconds will enter inclusion mode.
Exclusion Pressing On/Off button three times within 1.5 seconds will enter exclusion mode.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 On/Off righ switch (Lifeline)
2 5 On/Off left switch 
3 5 On/Off dopple klick righ switch
4 5 All On/Off

Configuration Parameters

Parameter 1: Night light


Size: 1 Byte, Default Value: 1

Setting Description
0 off
1 on

Parameter 2: Memory function


Size: 1 Byte, Default Value: 1

Setting Description
0 off
1 on

Parameter 3: Invert switch


Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Invert switch

Parameter 4: LED transmission indication

The switch will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set.

Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 1 second
2 Constantly

Parameter 5: Suspend group 4

You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “disassociating” those devices from the group. Setting parameter 5 to the value of 1 will stop the switch from transmitting to devices that are “associated” into Group 4.
Size: 1 Byte, Default Value: 0

Setting Description
0 sending
1 not sending

Technical Data

Dimensions 0.0800000x0.0800000x0.0380000 mm
Weight 87 gr
Hardware Platform ZM5202
EAN 695917446647
IP Class IP IP 20
Voltage 230 V
Load 1380 W x 2
Device Type Two channel wall switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 02.00
Z-Wave Version 04.05
Z-Wave Product Id 0x0118.0x0003.0x0001
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeTwo channel wall switch