Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Press the socket on/off button three times within 1.5 seconds to be included.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This smart energy plug is able to detect current wattage (5-3000W) and overload wattage (3010-3300W) of connected lights or appliances. When detecting overload state, the switch will be disabled and its on/off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch and it will reset its overload condition to normal status.

Installation

Plug this On/OFF Switch into a wall outlett.

Product Usage

LED Indication

To distinguish what mode he switch is in, view from the LED for identification



Choosing a Suitable Location

1. Do not locate the switch facing direct sinlight, humid or dusty place.
2. The suitable ambient temperature for the switch is 0-40°C
3. Do not locate the switch whre exists combusible substances or any source of heat, e.g. fires, radiators, boiler ect.
4. After putting into use. the body of switch will become a little bit hot of which phenomenon is normal.

Reset to factory default 1. To reset, press the socket on/off button three times within 1.5 seconds
2. then the fourth time, press and hold for seconds until the socket LED is off
3. the socket reset successfully Use the "Reset" procedure only in the event that the network primary controller is missing or otherwise inoperable
Inclusion Press the socket on/off button three times within 1.5 seconds to be included.
Exclusion Press the socket on/off button three times within 1.5 seconds to be excluded.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline

Configuration Parameters

Parameter 1: Change the state of indicator light


Size: 1 Byte, Default Value: 0

Setting Description
0 On -> LED ON
1 Off -> LED ON

Parameter 2: Memory function


Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 3: Watt Meter Report Period

If the setting configured for 1 hour (set value = 720), the TZ69 will report its instant power consumtion every 1 hour to Z-Wave Controller. The maximum interval to report its instand power consumption is 45 hours.
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 Time in 5 second steps

Parameter 4: KWH Meter Report Period

If the setting configured for 1 hour (set value = 6), the TZ69 will report its accumulated power consumtion every 1 hour to Z-Wave Controller. The maximum interval to report its instand power consumption is 227,55 Days.
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 Time in 10 minutes steps

Parameter 5: Threshold of Watt for Load Caution

In the above form, when the value is 3000, if Relay 1 load by below 3000 watt turned into more than 3000 watt, will immediately send the instantaneous load w value to Group 1.
Size: 2 Byte, Default Value: 3000

Setting Description
10 - 3000 Threshold Watt

Parameter 6: Thresold of KWH for Load Caution

In the above form, when the value is 10000, if Relay 1 load by below 3000 watt, when the accumulation of Relay 1 consumed power more than 10000 KWH, will immediately send the accumulation of current consumed power to Group 1.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 Thresold in KWH

Technical Data

Dimensions 0.0590000x0.0740000x0.1010000 mm
Weight 120.5 gr
Hardware Platform ZM5202
EAN 6959174469455
IP Class IP 20
Voltage 230V
Load 2500W
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.06
Certification ID ZC10-16075146
Z-Wave Product Id 0x0118.0x0004.0x0002
Supported Meter Type Electric Energy
Color White
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch