This is a
Press the socket on/off button three times within 1.5 seconds to be included.
This smart energy plug is able to detect current wattage (5-3000W) and overload wattage (3010-3300W) of connected lights or appliances. When detecting overload state, the switch will be disabled and its on/off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch and it will reset its overload condition to normal status.
Plug this On/OFF Switch into a wall outlett.
LED Indication
To distinguish what mode he switch is in, view from the LED for identification
Choosing a Suitable Location
1. Do not locate the switch facing direct sinlight, humid or dusty place.
2. The suitable ambient temperature for the switch is 0-40°C
3. Do not locate the switch whre exists combusible substances or any source of heat, e.g. fires, radiators, boiler ect.
4. After putting into use. the body of switch will become a little bit hot of which phenomenon is normal.
Reset to factory default | 1. To reset, press the socket on/off button three times within 1.5 seconds 2. then the fourth time, press and hold for seconds until the socket LED is off 3. the socket reset successfully Use the "Reset" procedure only in the event that the network primary controller is missing or otherwise inoperable |
Inclusion | Press the socket on/off button three times within 1.5 seconds to be included. |
Exclusion | Press the socket on/off button three times within 1.5 seconds to be excluded. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | On -> LED ON |
1 | Off -> LED ON |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
If the setting configured for 1 hour (set value = 720), the TZ69 will report its instant power consumtion every 1 hour to Z-Wave Controller. The maximum interval to report its instand power consumption is 45 hours. Size: 2 Byte, Default Value: 720
Setting | Description |
---|---|
1 - 32767 | Time in 5 second steps |
If the setting configured for 1 hour (set value = 6), the TZ69 will report its accumulated power consumtion every 1 hour to Z-Wave Controller. The maximum interval to report its instand power consumption is 227,55 Days. Size: 2 Byte, Default Value: 6
Setting | Description |
---|---|
1 - 32767 | Time in 10 minutes steps |
In the above form, when the value is 3000, if Relay 1 load by below 3000 watt turned into more than 3000 watt, will immediately send the instantaneous load w value to Group 1. Size: 2 Byte, Default Value: 3000
Setting | Description |
---|---|
10 - 3000 | Threshold Watt |
In the above form, when the value is 10000, if Relay 1 load by below 3000 watt, when the accumulation of Relay 1 consumed power more than 10000 KWH, will immediately send the accumulation of current consumed power to Group 1. Size: 2 Byte, Default Value: 10000
Setting | Description |
---|---|
1 - 10000 | Thresold in KWH |
Dimensions | 0.0590000x0.0740000x0.1010000 mm |
Weight | 120.5 gr |
Hardware Platform | ZM5202 |
EAN | 6959174469455 |
IP Class | IP 20 |
Voltage | 230V |
Load | 2500W |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16075146 |
Z-Wave Product Id | 0x0118.0x0004.0x0002 |
Supported Meter Type | Electric Energy |
Color | White |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |