Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Automatically add device to networkWhen a battery is inserted, the device is in automatical add mode for one minute (Network Wide Inclusion, NWI). This means that the device is added automatically when the Z-Wave controller enters add mode. Manual add device to networkStart the add mode on the Z-Wave controller. Press the button on the device three times fast. The device will now be added into the Z-Wave-network.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This magnet sensor contains the latest Z-Wave technology with the ability to remotely control other Z-Wave units available in your network. The fact that it is battery operated and so small you can virtually place it anywhere you wanton doors, windows or drawers, without the need of wiring. Screw or tape up the holder and then click the sensor in place. Done! The sensor is designed to be seen as little as possible and we have made it significantly smaller than other sensors. It consists of two parts that will merge into a stylish unit when the sensor is closed.

Reset to factory default Press and hold the button until the LED starts flashing (approx. 6 seconds).Press the button once more, short. The device will now reset to factory defaults. The LED will now flash, indicating that its no longer added in any Z-Wave network.Please note! Only use the reset procedure when the primary controller is missing or inoperable.
Inclusion Automatically add device to networkWhen a battery is inserted, the device is in automatical add mode for one minute (Network Wide Inclusion, NWI). This means that the device is added automatically when the Z-Wave controller enters add mode. Manual add device to networkStart the add mode on the Z-Wave controller. Press the button on the device three times fast. The device will now be added into the Z-Wave-network.
Exclusion Start the exclusion mode on the Z-Wave controller. Press the button on the device three times fast. The device will now be removed from the Z-Wave-network.
NIF XXXNIF
Wakeup Press the button on the sensor one time short to wake up the device.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline
2 10 Sensor statusThe sensor will send control commands to nodes in this group when the status of the sensor changes.
3 10 Sensor statusThe sensor will send control commands to nodes in this group when the sensor is opened only.

Configuration Parameters

Parameter 1: Select what type of command to be sent to nodes in association group 2

Select what type of command to be sent to nodes in association group 2
Size: 1 Byte, Default Value: 0

Setting Description
0 Basic
1 Switch Binary
2 Switch All
3 Switch Multilevel

Parameter 2: Select value that should be sent to association group 2

Select what value that should be sent to association group 2 when Swith Multilevel is set in configuration 1.Use 1-99 for specific dim-level, -1 return to last value. Should only be changed when Swith Multilevel is set in configuration 1.
Size: 1 Byte, Default Value: -1

Setting Description
0 - 99 Dim-level
-1 Last value

Parameter 3: Type of signals to association group 2

When this configuration is set to inverted, an off-signal will be sent when the sensor is opened and on-signal when it's closed instead of the opposite.
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal
1 Inverted

Parameter 4: Select what type of command to be sent to nodes in association group 3

Use Basic to control ON/OFF-devices, use Switch Multilevek to control dimmer-devices.
Size: 1 Byte, Default Value: 0

Setting Description
0 Basic
1 Switch Binary
2 Switch All
3 Switch Multilevel

Parameter 5: Select value that should be sent to association group 3


Size: 1 Byte, Default Value: -1

Setting Description
0 - 99 Dim-level
-1 Last value

Parameter 6: Type of signals to association group 2

When this configuration is set to inverted, an off-signal will be sent when the sensor is opened and on-signal when it's closed instead of the opposite.
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal
1 Inverted

Parameter 7: LED-Indicator

Select if the LED indicator shold be active or not. Turn it off to reduce the power consumption.
Size: 1 Byte, Default Value: 1

Setting Description
0 OFF
1 ON

Parameter 8: Type of command to be sent in the Lifeline


Size: 1 Byte, Default Value: 0

Setting Description
0 Notification
1 Sensor binary

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-15100003
Z-Wave Product Id 0x0176.0x0005.0x0001
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor