This is a
Automatically add device to networkWhen a battery is inserted, the device is in automatical add mode for one minute (Network Wide Inclusion, NWI). This means that the device is added automatically when the Z-Wave controller enters add mode. Manual add device to networkStart the add mode on the Z-Wave controller. Press the button on the device three times fast. The device will now be added into the Z-Wave-network.
This magnet sensor contains the latest Z-Wave technology with the ability to remotely control other Z-Wave units available in your network. The fact that it is battery operated and so small you can virtually place it anywhere you wanton doors, windows or drawers, without the need of wiring. Screw or tape up the holder and then click the sensor in place. Done! The sensor is designed to be seen as little as possible and we have made it significantly smaller than other sensors. It consists of two parts that will merge into a stylish unit when the sensor is closed.
Reset to factory default | Press and hold the button until the LED starts flashing (approx. 6 seconds).Press the button once more, short. The device will now reset to factory defaults. The LED will now flash, indicating that its no longer added in any Z-Wave network.Please note! Only use the reset procedure when the primary controller is missing or inoperable. |
Inclusion | Automatically add device to networkWhen a battery is inserted, the device is in automatical add mode for one minute (Network Wide Inclusion, NWI). This means that the device is added automatically when the Z-Wave controller enters add mode. Manual add device to networkStart the add mode on the Z-Wave controller. Press the button on the device three times fast. The device will now be added into the Z-Wave-network. |
Exclusion | Start the exclusion mode on the Z-Wave controller. Press the button on the device three times fast. The device will now be removed from the Z-Wave-network. |
NIF | XXXNIF |
Wakeup | Press the button on the sensor one time short to wake up the device. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
2 | 10 | Sensor statusThe sensor will send control commands to nodes in this group when the status of the sensor changes. |
3 | 10 | Sensor statusThe sensor will send control commands to nodes in this group when the sensor is opened only. |
Select what type of command to be sent to nodes in association group 2 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Basic |
1 | Switch Binary |
2 | Switch All |
3 | Switch Multilevel |
Select what value that should be sent to association group 2 when Swith Multilevel is set in configuration 1.Use 1-99 for specific dim-level, -1 return to last value. Should only be changed when Swith Multilevel is set in configuration 1. Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 99 | Dim-level |
-1 | Last value |
When this configuration is set to inverted, an off-signal will be sent when the sensor is opened and on-signal when it's closed instead of the opposite. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal |
1 | Inverted |
Use Basic to control ON/OFF-devices, use Switch Multilevek to control dimmer-devices. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Basic |
1 | Switch Binary |
2 | Switch All |
3 | Switch Multilevel |
Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
0 - 99 | Dim-level |
-1 | Last value |
When this configuration is set to inverted, an off-signal will be sent when the sensor is opened and on-signal when it's closed instead of the opposite. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal |
1 | Inverted |
Select if the LED indicator shold be active or not. Turn it off to reduce the power consumption. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | OFF |
1 | ON |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Notification |
1 | Sensor binary |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15100003 |
Z-Wave Product Id | 0x0176.0x0005.0x0001 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |