Quickstart

This is a On/Off Power Switch for Europe. To run this device please insert fresh 1 * CR123 batteries. Please make sure the internal battery is fully charged.

Inclusion, Exclusion and wakeup are confirmed by one second clicking the program switch inside the case.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

This sensor monitors leakage and sends an alarm when flooding or leakage is detected. The sensing device can be away up to 2 m from the main device. The unit can be mounted on every flat surface. The installation can be done with screws or double-sided tape.

The device is a battery-powered device, which is in non-operating state unless an action is detected. After a programmable sleeping time the device wakes up and sends status information. After this the unit goes back to non-operating state. The unit will sends a warning to the Z-Wave controller, when batteries need to be replaced. The units send information to a controller or any other associated Z-Wave device. The device has a tamper switch which sends an alarm to the controller when it will be opened.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.

Installation

NOTE: A clean smooth surface is required to mount the Flood Sensor securely. The length of flood sensor cable is 2 meters. If the cable is too long, roll up the cable and fasten it by twist ties. The transceiver should be placed as high up as possible on the wall to improve communication and to prevent it from coming into contact with water in case of flooding.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Click one second on the program switch inside the device to confirm the process.

Exclusion

Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Click one second on the program switch inside the device to confirm the process.

Product Usage

  1. When water is detected, the sensor transmits radio signal to controller.
  2. In normal operation the LED in the device will not light.
  3. If the cover of the device is removed, the tamper switch will send a signal according the status, the LED will go solid. The sensor will go to wake up, when it is opened.

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. To issue a NIF execute the following action:

Click one second on the program switch inside the device or a detected action by the sensor sends a Node Information Frame.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action:

Click one second on the program switch inside the device or a detected action by the sensor will wake up the device and keep it awake.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 Flood detected

Technical Data

Dimensions 0.0420000x0.0740000x0.0260000 mm
Weight 35 gr
Hardware Platform ZM3102
Battery Type 1 * CR123
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Firmware Version 0e.01
Z-Wave Version 03.53
Certification ID ZC10-14040002
Z-Wave Product Id 0109.2005.0505
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

Explanation of Z-Wave specific terms