Quickstart

This is a Z-Wave Device for XXXQFrequencyName. To run this device please insert fresh 2 * AA batteries. To run this device please make sure the internal battery is fully charged.

Exclusion, Inclusion and wakeup are confirmed by hitting the programm button.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This Smoke Detector uses a non-radioactive photoelectron-sensor for a reliable and safe detection of smoke. The smoke sensitivity is 0.5 % /ft ? 4 % /ft. The smoke detector has a test button and a flashing LED, so you always know that the smoke alarm is working correctly. The smoke alarm will warn you when the battery is low. When the device detects smoke, it will give a loud warning sound. It will also trigger actions in other Z-Wave devices or Z-Wave controllers to escalate the alarm. The Smoke Detector can also activate an alarm-scenario within the Z-Wave network. For example you can create an alarm-scenario to switch on all lights in the house when smoke is detected. Even at the middle of the night, you may leave the house very quickly when smoke is detected.

Installation

  • Remove the bracket from the detector by rotating it counter-clockwise.
  • Place the bracket where you are going to install the detector. In each of keyhole slots, draw a mark to locate plastic anchor and screw. Using a 3/16-inch (5mm) drill bit, drills two holes at the marks and insert plastic anchor, and attached the bracket by using the screws.
  • Open the battery cover to insert the batteries, and then replace the cover. Fix the detector with bracket by rotating it clockwise.

Please follow the recommendations about amount as position of the sensor in your home as given above. Avoid to place the sensor into the angle of walls, prefer positions in the middle of the room.

Product Usage

  • Power-on Mode: 1) Install the battery into the module 2) Close the bracket
  • 3) the detector will take 8 to 12 sec. and emit a beep to confirm and start the burglar system. The detector will alarm once remove the bracket.
  • Stand-by Mode: The red LED flashes one time every 11 seconds.
  • Alarm Mode (It is the status when the alarm is triggered.): If a certain density of smoke is detected, an audible alarm with 3 beeps, break and 3 beeps will occure. The red LED will flash continuously and rapidly. Meanwhile, the smoke detector will send an alarm report (type: smoke alarm, state: alarm) to the user?s controller and also the detector will send an alarm report (type: smoke alarm, state: No alarm).
  • Error Mode: If the smoke detector beeps and yellow LED flashes three times, it indicates the smoke detector is not working properly. Please require to repair or service.
  • Low battery warning Mode: The yellow LED will flash once every 43 seconds with a short ?beep? sound.
  • Testing Mode: Test the alarm weekly by pushing the test switch for about 3 sec. until there are 3 beeps and red LED light on continuously. Then, the smoke detector will send an alarm report (type: smoke alarm, state: alarm) to the user?s controller and also the dectecor will send an alarm report (type: smoke alarm, state: No alarm). Please note if the detector only beep once and red LED flashes three times, it indicates the detector is not working properly. Please require to repair or service.
  • Battery Power indicator: The detector will report the current status of battery capacity to the user?s controller.
  • Self-Protection Mode: If the detector is removed from bracket, the detector will send an alarm (type:smoke alarm, level:0xFF) to the Z-Wave Interface Controller, and the yellow LED will flash continuously and the detector will sound.
  • Silence Mode: The user could press the test switch to get into silence mode to turn off the alarm temporarily. The silence function will automatically turn into normal operation after 10 minutes if the smoke concentration around the detector is still at alarming level.

Reset to factory default XXXResetDescription
Inclusion

Exclusion and Inclusion is confirmed by hitting the programm button.

Exclusion

Exclusion and Inclusion is confirmed by hitting the programm button.

NIF

Hitting the programm button will send out an Node Information Frame.

Wakeup

Hitting the programm button will wake up the device.

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 alarm messages

Technical Data

Dimensions 0.1180000x0.1180000x0.0430000 mm
Weight 150 gr
Hardware Platform ZM3102
Battery Type 2 * AA
Firmware Version 03.05
Z-Wave Version 03.28
Certification ID ZC10-14080007
Z-Wave Product Id 0109.200f.0f02
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeZ-Wave Device