Quickstart

This is a Z-Wave Device for XXXQFrequencyName. To run this device please insert fresh 2 * AA batteries. To run this device please make sure the internal battery is fully charged.

Inclusion and Exclusion is confirmed by hitting the program button. Hitting the program button will wake up the device.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Carbon Monoxide (CO) is a tasteless, invisible but very poisonous gas created among others by incomplete burning of burnable material or gas. This device is measuring the CO concentration in the air and issues an alarm when a certain level of CO is exceeded. The device will send an alarm when one of the following conditions are met:

  • 50 ppm for 60 minutes
  • 100 ppm for 10 minute
  • 300 ppm for 3 minutés

Additionally a remote device can be switched. This can be an actuator e.g. opening a door or another alarm device such a siren. The device consists of a mounting base that is screwed to the wall and the actual device is mounted to this base. It is recommended to place the CO sensor on the sealing because CO is lighter than air and will always move upwards. The device is battery-operated and therefore in sleeping mode unless an action is detected. After a programmable sleeping time the device wakes up and sends a status information. After this the unit goes back to sleeping modus. Batteries can be changed without unscrewing the mounting base. The unit has tree colored LED to give visual warning when the battery is low or a CO alarm occurred.

Installation

  1. Remove the bracket from the detector by rotating it counter-clockwise.
  2. Place the bracket where you are going to install the detector. In each of keyhole slots, draw a mark to locate plastic anchor and screw. Using a 3/16-inch (5mm) drill bit, drills two holes at the marks and insert plastic anchor, and attached the bracket by using the screws.
  3. Open the battery cover to insert the batteries, and then replace the cover. Fix the detector with bracket by rotating it clockwise.

Please follow the recommendations about amount and position of the sensor in your home as given above. Avoid to place the sensor into the angle of walls, prefer positions in the middle of the room.

Product Usage

  • Power-on Mode: 1) Install the battery into the module 2) The detector will emit a beep in 0.5 seconds and the three LEDs will flash once quickly. 3) Close the bracket. The CO detector will alarm once remove the bracket.
  • Stand-by Mode: The Green LED flashes one time every 60 seconds.
  • Alarm Mode (It is the status when the alarm is triggered.): If a certain density of CO is detected, an audible alarm with 4 beeps, pause 5 seconds and 4 beeps will occure. The red LED will flash continuously and rapidly. Meanwhile, the CO detector will send an alarm report (type: CO alarm, state: alarm) to the user?s controller and also the CO dectecor will send an alarm report (type: CO alarm, state: No alarm) while the alarm goes off.
  • Error Mode: If the CO detector beeps once and yellow LED flashes three times every minute, it indicates the CO detector is not working properly. Please require to repair or service.
  • Low battery warning Mode: The yellow LED will flash once every minute with a "beep" sound.
  • Low sensitivity Mode: The yellow LED will flash twice every minute with a "beep" sound. It indicates the CO detector has internal problem, please replace the unit.
  • Tamper Mode: The yellow LED will go solid and the detector will emit a short beep every minute until the CO detector is mounted back to the bracket properly.
  • End of life signal Mode: The yellow LED will flash four times every minute with a short "beep" sound. It indicates the CO detector is reaching to the end of useful life, please replace with a new unit.
  • Testing Mode: Test the alarm by pushing test switch until the user hears 4 short beeps and three LEDs flash synchronously in five seconds. Then, the CO detector will send an alarm report (type: CO alarm, state: alarm) to the user?s controller and also the CO dectecor will send an alarm report (type: CO alarm, state: No alarm) while the alarm goes off. Please note if the CO detector only beeps once and yellow LED flashes three times every minute, it indicates the CO detector is not working properly. Please require to repair or service.
  • Battery Power indicator: The detector will report the current status of battery capacity to the user?s controller.
  • Self-Protection Mode: If the cover of detector removed from bracket, after 8 sec the detector will send an alarm report (type:0*02, level:0*FF) to the Z-Wave Interface Controller and the yellow LED will flash continuously and the detector will sound.
  • Silence Mode: The user could press the test switch to get into silence mode to turn off the alarm temporarily when the CO detector alarms. Meanwhile, the red LED will flash continually. The silence function will automatically turn into normal operation if the CO concentration around the CO detector is still at alarming level after 4 minutes of silence mode.

WARNING: The carbon monoxide sensing unit has only 5-year limited life. For the security issue, we strongly recommend the user to change whole the CO detector after 4-year usage.

Reset to factory default XXXResetDescription
Inclusion

Inclusion and Exclusion is confirmed by hitting the program button.

Exclusion

Inclusion and Exclusion is confirmed by hitting the program button.

NIF

Hitting the program button will send out an Node Information Frame

Wakeup

Hitting the program button will wake up the device.

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 alarm messages

Technical Data

Dimensions 0.1230000x0.1230000x0.0300000 mm
Weight 152 gr
Hardware Platform ZM3102
EAN 0696859123481
Battery Type 2 * AA
Firmware Version 03.05
Z-Wave Version 03.28
Z-Wave Product Id 0109.200f.0f02
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeZ-Wave Device