1. Put your system controller into inclusion mode by following the instructions provided by your controller manufacturer.
2. Press the push button (B) located on the top of the device once."
The smallest device in its category worldwide, and the only device specifically intended for use both as a Relay Switch with integrated power meter, and as an Energy Meter either at the point of entry of your electrical system, or on a section of the latter. Available in two versions, version S featuring an internal shunt resistor, and version C featuring an external current transformer, it is capable of measuring loads exceeding 10 KW. In addition to Power measurements, the device also provides data for Energy, Voltage, Current and Power factor.
The only device suited for use with all types of Z-Wave controller, and capable of implementing an active energy-saving management policy defined by the user according to his energy consumption, or to the amount of energy produced by his solar power system. It automatically connects and disconnects a specific load if the threshold limit is exceeded, or “supplies†the required power, momentarily excluding non-priority loads.
WiDom Driven Switch Activation
1) Ensure that the main power switch is set in the OFF position
2) Connect the device following the diagrams provided
3) Shut the electrical box containing the device
4) Turn the main power switch back on
5) Include the device into the Z-Wave network
Electrical Connections
The device must be supplied by phase and neutral. Connections must be made according to one of the diagrams below.
Local load control
In this mode the load is controlled directly by the internal relay. The opening and closing of the relay contacts are synchronized to take place, respectively, when a zero current or voltage is reached.
Remote load control
In this mode the device has no locally connected load, and the measures of current and power are based on all devices connected to the “LINE OUT” section of the system. The devices connected to the “LINE OUT” can be controlled individually based on the configured energy events.
Reset to factory default | Press the push button (B) located on the top of the device six consecutive times within one minute from system start-up. |
Inclusion | Press the once push button (B) located on the top of the device or push once the external Switch. |
Exclusion | Press the three times the push button (B) |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline:Devices to receive notifications on: status changes; energy and power levels; device local reset |
2 | 8 | Up Power Level Group:Devices controlled by the Up Power event |
3 | 8 | Down Power Level Group:Devices controlled by the Down Power event |
Controlling the relay by means of a single click on the external switch or on the integrated button. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | TOGGLE |
2 | ON |
3 | OFF |
4 | IGNORE |
The final status achieved by the device when it receives a Basic Set command through the Z-Wave network. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | AS RECEIVED |
2 | IGNORE IF ON |
3 | IGNORE IF OFF |
4 | IGNORE |
Sets the current level above which the time spent above that level is measured. Size: 2 Byte, Default Value: 1250
Setting | Description |
---|---|
0 - 1250 | Overcurren level in hundredths of Amperes |
Sets the time beyond which, in the case of overcurrent at a level higher than that established in parameter 30, an OverCurrent event occurs. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 10800 | Time in seconds |
Defines the next state of the device if an overcurrent event has occurred. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | IGNORE |
1 | ON |
2 | OFF |
3 | TOGGLE |
Provides total operating time from last meter reset. When set to 0 it resets the cumulated values of energy and total operating time. Size: 4 Byte, Default Value: 1
Setting | Description |
---|---|
0 | RESET METER |
Determines whether energy events are related to energy consumed or energy produced. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Consumed |
2 | Produced |
Sets the level of instantaneous power in Watts beyond which time of permanence above this level is calculated. Size: 2 Byte, Default Value: 3000
Setting | Description |
---|---|
0 - 3000 | UP Power level in Watt |
Sets the time in seconds beyond which, if instantaneous power remains at levels exceeding threshold defined by parameter 35, a UP Power event occurs. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 10800 | UP Power Time in seconds |
Defines the status of associated devices in the presence of a UP Power event. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | OFF |
1 - 99 | Dimming |
100 | ON |
Sets the level of instantaneous power beyond which the time of permanence below this level is calculated. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 11250 | DOWN Power Level in Watt |
Sets the time beyond which, if instantaneous power remains at levels below threshold defined by parameter 39, a DOWN Power event occurs. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 10800 | DOWN Power Time in seconds |
Defines the next state of the device in the case of a DOWN Power event occurring. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | IGNORE |
1 | ON |
2 | OFF |
3 | TOGGLE |
Defines the status of associated devices in the presence of a DOWN Power event. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | OFF |
1 - 99 | Dimming |
255 | ON |
Sets the energy level that once exceeded an Energy Limit event occurs. Size: 4 Byte, Default Value: 2000000
Setting | Description |
---|---|
0 - 2000000 | Energy Level in KWh |
Defines the next state of the device in the case of an Energy Limit event occurring. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | IGNORE |
1 | ON |
2 | OFF |
3 | TOGGLE |
Defines the percentage variation of instantaneous power determining the sending of the report. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 100 | Power variation in percentage |
Defines the maximum time in minutes since the previous report beyond which an Instantaneous Power Report will still be sent. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 100 | Time in minutes |
Defines the nominal voltage value in tenths of volts. Together with parameter No. 49 this is used by the automatic notification system to send reports on variations of voltage. Size: 2 Byte, Default Value: 2300
Setting | Description |
---|---|
1100 - 2300 | Nominal Voltage in Volt |
Defines, as a percentage, the nominal value for permitted fall in maximum voltage. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 100 | percentage of voltage variation |
Defines which electric parameters, other than power, will be subjected to automatic notification.The value to be set for this parameter must be calculated as the sum of values associated to the individual electric parameter. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 | Power |
2 | Energy |
4 | Voltage |
8 | Current |
16 | Power Factor |
32 | Multilevel Sensor: Power Report |
Defines the status of the device following a restart. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | ON |
2 | OFF |
3 | Status prior to restart |
Defines which parameters should be reset to default values. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 | FACTORY RESET |
1 | ASSOCIATIONS RESET |
2 | CONFIGURATIONS RESET |
4 | IGNORE |
Defines the type of external switch connected to the device. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 | IGNORE |
1 | BUTTON |
2 | SWITCH |
4 | AUTOMATIC RECOGNITION |
Defines the load control mode. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | DIRECT CONTROL |
2 | CONTROL BY MEANS OF A CONTACTOR WITH NORMALLY OPEN COMMAND |
3 | CONTROL BY MEANS OF A CONTACTOR WITH NORMALLY CLOSED COMMAND |
4 | AS AN EXTERNAL INDICATOR |
Dimensions | 0.0370000x0.0370000x0.0170000 mm |
Weight | 70 gr |
Hardware Platform | ZM5202 |
EAN | 8059265060023 |
IP Class | IP 20 |
Voltage | 230V |
Load | 12,5A |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.03 |
Certification ID | ZC10-15030011 |
Z-Wave Product Id | 0x0149.0x1214.0x0304 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |