Quickstart

This is a secure Motor Control Device (C) for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Pressing any sequence of click on the integrated button.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

WiDom Smart Rollladen ist ein "Unterputz Gerät" zur mehrstufigen Steuerung von Rollladenmotoren. Es kann das Öffnen und Schließen von Jalousien, Vorhängen, Rollläden und Jalousien genau steuern, wie es der Benutzer durch lokale Befehle oder per Fernzugriff über Computer, Smartphones und Tablets wünscht. 
 
Gleichzeitig ist es vollständig konfigurierbar, so dass es sich an die unterschiedlichsten Kundenbedürfnisse anpassen und einsatzbereit ist, ohne zusätzliche Konfigurationen für den Betrieb zu benötigen. 
 
Nach einer ersten Kalibrierung ist WiDom Smart Roller Shutter dank eines proprietären Algorithmus in der Lage, die genaue Position des Rollladens ohne Verwendung externer Sensoren zu ermitteln. Während des Betriebs ermöglicht eine kontinuierliche und automatische Steuerung der Endschalter die Aufrechterhaltung der Kalibrierung. In Abwesenheit einer Stromquelle führt das System ein Selbstrepositionierungsverfahren durch, das die Kalibrierung wiederherstellt. 
 
Das Gerät ist mit einer Kontaktschutztechnologie (Zero Crossing) ausgestattet, die die elektrische Belastung der Relaiskontakte reduziert und eine längere Lebensdauer gewährleistet. Das Auf/Zu-Schalten des Gerätes erfolgt immer dann, wenn der momentane Spannungswert 0 ist.
 
Es funktioniert in jedem Z-Wave-Netzwerk mit anderen Z-Wave/Z-Wave Plus-zertifizierten Geräten und Controllern anderer Hersteller. Als ständig mit Strom versorgter Knoten fungiert der WiDom Smart Roller Shutter unabhängig vom Hersteller als Repeater, um die Zuverlässigkeit des Netzwerks zu erhöhen.

Installation

N) Neutral
L) Phase
1 and 2) Motor terminals
I1, I2) Commands switch

Product Usage

LED status indicator

The system includes an RGB LED that shows the device’s status during installation:
Solid RED: the device is not included in any network
OFF: the device is already associated with a Z-Wave network
Blink GREEN: the device has sent an unsolicited Multilevel Frame to Lifeline group
Blink YELLOW: the device has sent an unsolicited Meter Frame to Lifeline group 
Blink VIOLET: the device has sent a command to the association device. The number of blinks is equal to the ID Association group
Blink BLUE: calibration
A sequence of GREEN-BLUE Learn Mode for inclusion
A sequence of RED-BLUE Learn Mode for exclusion

Calibration
The calibration is the procedure through which the system carries out a mapping of the positions taken by the roller shutter and the motor functioning parameters. After this procedure is executed, it will be possible to control the shutter movement and to indicate the exact position it has to reach.
The calibration procedure runs automatically as soon as the system is included in a Z-Wave network and it can be activated again by using Parameter No. 20.
The system precision depends on several factors such as the motor type, the limit switches sensitivity, the shutter type, etc. Statistically, the maximum error occurring while reaching a set position, starting from top or from the bottom is lower than the height of a single shutter batten.
The start of the calibration procedure requires the system to completely run twice, from being completely closed to completely open and to stop then in the final position.

Favorite Positions
The system can set two favorite positions: one for the upward movements (opening movements) Favorite level for ON position, the other for the downward movements (closing movements) Favorite level for OFF position. These positions can be activated by the user through a single/double click (Parameter No.1) on the UP button or on the DOWN button respectively. The levels of favorite positions can be configured using parameters No. 2 and No. 3 (see Configuration section).

Controlling the device
With WiDom devices, the normal switches/buttons found in a traditional electrical system can become intelligent control systems.

Controlling the WiDom Smart Roller Shutter by External switches
The clicks/hold on the external switches control the shutter movements. WiDom framework recognizes the number of clicks or hold an event on the external switch and can be configured to perform different actions based on the identified event.

External switch: Double command button: UP/DOWN, open/close, ON/OFF
Events: The actions performed on the external Switch: Clicks or Hold.
Click: A click means pressing the button and then releasing it.
Hold: This applies only to buttons that are normally open and that are identified as such when the pressure phase lasts at least 0.3 seconds.
Device status: ON/OFF/STOP, Open/Close/Stop refers to the fact that the motor is rotating towards the direction Open/Close or it is stopped.

Control Actions
- Holding the UP/DOWN button makes the motor move in the relevant direction, and stops it as soon as the button is released or the shutter reaches its limit switch.
- An action ordering an UP/DOWN movement while the motor is moving in the opposite direction will stop the motor.
- An action ordering an UP/DOWN movement while the motor is moving in the same direction will be ignored.
- A single and/or a double click (Parameter No.1) on the button UP/DOWN makes the motor move until it reaches the favorite position set for the UP/DOWN position.
 

Reset to factory default Press 6 consecutive clicks on the integrated button.
Inclusion Pressing any sequence of click on the integrated button.
Exclusion Pressing any sequence of click on the integrated button.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Lifeline
2 8 Controls relays or dimmers
3 8 Controls relays or dimmers
4 8 Controls relays or dimmers

Configuration Parameters

Parameter 1: Numbers of clicks to control the local load

Define which sequences of click control the local load.
Size: 1 Byte, Default Value: 3

Setting Description
0 Local Control disabled
1 1 click control the local load
2 2 clicks control the local load
3 1 clicks and 2 clicks control the local load

Parameter 2: Favorite level for ON position


Size: 1 Byte, Default Value: 100

Setting Description
50 - 100 50-100% opening level (100% correspond to completely open)

Parameter 3: Favorite level for OFF position


Size: 1 Byte, Default Value: 0

Setting Description
0 - 49 0-49% opening level (0 correspond to completely closed)

Parameter 4: Value used for devices belonging to Group 2 when UP button receive 1 Click

Defines the actions to be carried out on the associated devices in terms of Basic Set.
Size: 1 Byte, Default Value: 255

Setting Description
0 Off
1 - 99 Dimming purpose
255 ON

Parameter 5: Value used for devices belonging to Group 2 when DOWN button receive 1 Click

Defines the actions to be carried out on the associated devices in terms of Basic Set.
Size: 1 Byte, Default Value: 255

Setting Description
0 Off
1 - 99 Dimming purpose
255 ON

Parameter 6: Value used for devices belonging to Group 3 when UP button receive 1 Click

Defines the actions to be carried out on the associated devices in terms of Basic Set.
Size: 1 Byte, Default Value: 255

Setting Description
0 Off
1 - 99 Dimming purpose
255 ON

Parameter 7: Value used for devices belonging to Group 3 when DOWN button receive 1 Click

Defines the actions to be carried out on the associated devices in terms of Basic Set.
Size: 1 Byte, Default Value: 255

Setting Description
0 Off
1 - 99 Dimming purpose
255 ON

Parameter 8: Value used for devices belonging to Group 4 when UP button receive 1 Click

Defines the actions to be carried out on the associated devices in terms of Basic Set.
Size: 1 Byte, Default Value: 255

Setting Description
0 Off
1 - 99 Dimming purpose
255 ON

Parameter 9: Value used for devices belonging to Group 4 when DOWN button receive 1 Click

Defines the actions to be carried out on the associated devices in terms of Basic Set.
Size: 1 Byte, Default Value: 255

Setting Description
0 Off
1 - 99 Dimming purpose
255 ON

Parameter 20: Calibration

Defines the status of the calibration procedure. By default, as soon as the device has been included, the calibration starts in automatic mode. At the end of the calibration, this parameter is set to 1.
Afterwards, the calibration can be done again by setting this parameter to 0 (AUTO) or 2 (MANUAL) and clicking on any external button.
If the calibration is set in AUTO mode, it will be completed automatically.
If the calibration is set in MANUAL mode, a click on any external button is necessary to carry on the next step.
During the calibration, the LED indicator blinks repeatedly in BLUE.

Size: 1 Byte, Default Value: 0

Setting Description
0 Calibration to be done in automatic mode
1 Calibration has been done
2 Calibration to be done in manual mode

Parameter 21: Motor idle state definition

Defines the level of power consumption under which the motor is considered in idle state
Size: 2 Byte, Default Value: 1000

Setting Description
0 - 3000 Expressed in hundredths of Watt (ex. 3000=30 Watt)

Parameter 22: Limit switch recognition

Defines the time after which, a power consumption lower than the PLIMIT (the power defined in parameter No. 21) is considered as reaching the limit switch
Size: 1 Byte, Default Value: 30

Setting Description
0 Limit Switch ignored
1 - 127 Expressed in tenths of seconds

Technical Data

Dimensions 37x37x17 mm mm
Weight 26.6 gr
Hardware Platform ZM5101
EAN 8059265060092
IP Class IP 20
Voltage 230 V
Load 1200 W
Device Type Roller Shutter
Generic Device Class Multilevel Switch
Specific Device Class Motor Control Device (C)
Firmware Version 01.00
Z-Wave Version 06.04
Z-Wave Product Id 0x0149.0x1214.0x0800
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeRoller Shutter