Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZF5201 to the controller. To get in the inclusion mode, the distance between sensor and controller is suggested to be in one meter. Press the program switch of ZF5201 for 1 second at least. The LED on the ZF5201 should go solid, if not, please try again



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This sensor sends Z-Wave signal while detecting water. The sensor can be put under the refrigerator, and it will trigger while detecting the leaking water. You can also install the sensor at anywhere it leaks; with this sensor you can avoid loss before it flood.When the device is secure included into Z-Wave network, above communication will be encrypted.

Reset to factory default Triger the Water Sensor 10 times within 10 sec.The device will send command class of device reset to controller and back to the factory default state.Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZF5201 to the controller. To get in the inclusion mode, the distance between sensor and controller is suggested to be in one meter. Press the program switch of ZF5201 for 1 second at least. The LED on the ZF5201 should go solid, if not, please try again
Exclusion For Exclusion from (removing from) a network: Put the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZF5201 from your controller.Press the program switch of ZF5201 for 1 second at least to be excluded.
NIF XXXNIF
Wakeup Awake mode: it is to leave the Sleep mode by removing the cover of ZF5201, to allow the Z-Wave Interface Controller to do Inclusion, Exclusion, Association and to reply and receive the commands from controller.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 02
Z-Wave Version 6.51.06
Certification ID ZC10-15050015
Z-Wave Product Id 0x0109.0x201C.0x1C03
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor