Quickstart

This is a Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:

- Click [Add] icon in Z-Wave Controller.
- Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
- If add Process is successful, Green LED will turn on.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This Smart Combustible Gas Sensor adopts super low power consumption Z-Wave Wireless module. Used for detecting combusting gas leakage and preventing danger caused by gas leakage it also can be used as Z-Wave repealer to extend wireless transmission distance. It adopts high stability semi-conductor gas sensor. Sensor alarms if gas density in air exceeds set alarm level. It is applicable for kitchen or possible gas leakage in in-door area.

Installation

Liquefied petroleum gas should be isntalled at 0.3-1m height from floor and semi-conductor of sensor installation position to gas source should be less than 1.5m. Natural gas, manufactured gas, marsh gas, etc. should be be installed at 0.3-1m bellow from ceiling, semi-diameter to gas source less than 1.5m.

Product Usage



1. Shell surface will be slightly hot while working, which is normal phenomenon
2. Please dismantle sensor while decorating house
3. Avoid spraying aerosol around sensor
4. Oil adhension around gas convenction holes may effect the senistivity of gas sensor after long time of use. It’s suggested to clear gas convenction holes every 3 months (with little detergent, but with care so it doesn’t enter the body of the sensor).
5. Semi-conductor of gas sensor has 5 year lifespan
6. Don’t use lighter to test the sensor directly

Starting up
 
The green LED lights up after power on the sensor, when a “beep” sounds once, the sensor enters into warm-up state then red and yellow LED flash alternately. Eventually the flash stops 3 minutes later, which indicates that the sensor has entered into normal working state. Don’t the senor while it’s in warm-up state.

LIGHT STATE & PRODUCT TEST

STATE COLOR LIGHT ALARM SOUND
Power Green Normally on No
Alarm Red Flashing gas alarm
Malfunction Yellow Normally on Long buzz

Test button of this sensor is used for testing wheater LED indicator and buzzer can work properly. Red LED and yellow LED flash alternatively with buzzer alarm when the test button is pressed.


Reset to factory default
- Long press Net_Button at least 10 seconds in the device.
- Device Reset Locally notification is Transmitted.
Inclusion
- Click [Add] icon in Z-Wave Controller.
- Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
- If add Process is successful, Green LED will turn on.
Exclusion
- Click [Remove] icon in Z-Wave Controller.
- Press the Net_Button 3 times within 1.5s
- If remove Process is successful, Green LED is Blinking 6 times, then turn on
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline
2 5 Gas Alarm (Notification Type Gas Alarm (0x12))

Technical Data

Dimensions 0.0680600x0.0777200x0.0791600 mm
Weight 90.25 gr
Hardware Platform ZM5202
EAN 3858890733587
IP Class IP 20
Voltage 230V
Load 1,5W
Device Type Sensor
Firmware Version 01.01
Z-Wave Version 04.26
Certification ID ZC10-17115882
Z-Wave Product Id 0x0131.0x8003.0x1000
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW