This is a
For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZL7261 into your controller.To get in the Inclusion mode, the distance between ZL7261 and controller is suggested to be in one meter. By power up to get included for first time, or press the Program switch (The LED at the top of plug-in) 3 times within 2 seconds to be included.
This Power Monitoring On/Off Module is a Z-Wave enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave enabled network. Every main powered Z-Wave enabled device acts as a signal repeater and multiple devices result in more possible transmission routes, which helps eliminate RF dead-spot.Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enabled networks.This module will send On/Off signal to the appliance that attached to this module by receiving Z-Wave signal from controller or manually switch.It also sends the energy consumption to the controller when it requests.With special design, this module wont interfere the other power outlet when plug into the AC outlet.This module also acts as repeater (supporting FLiRS).
Reset to factory default | Reset: Press the Program Switch (The LED at the top of plug-in) then power on (plug-in) and hold for 5 seconds before release the switch.Noticed:only use Reset for the situation where the primary controller is inoperable or lost. |
Inclusion | For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZL7261 into your controller.To get in the Inclusion mode, the distance between ZL7261 and controller is suggested to be in one meter. By power up to get included for first time, or press the Program switch (The LED at the top of plug-in) 3 times within 2 seconds to be included. |
Exclusion | For Exclusion from (removing from) a network: Set up the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZL7261 from your controller.Press the Program Switch (The LED at the top of plug-in) 3 times within 2 seconds to be excluded. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Central Static Controller Lifeline Signals |
Automatic Meter Report interval for kWh/kVAh Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
60 - 255 | The number of seconds desired between automatic meter reports. |
The change in watt consumption that will cause the transmission of voltage, current, and wattage to be sent. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
5 - 3600 | The number of watts change to cause reports to be sent. |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | 02 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-14080003 |
Z-Wave Product Id | 0x0109.0x201A.0x1A02 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |