This is a
Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZL 7434-5 to your controller.To get in the inclusion mode, the distance between module and controller is suggested to be in one meter. Press 3 times program switch within 2 seconds or turn on the wall switch 3 times within 2 seconds (or press toggle switch 3 times) to be included.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This module provides On/Off control for the appliance that is attached to this module by Z-Wave.It also can control two appliances independently.When the device is secure included into Z-Wave network, Z-Wave communication will be encrypted.* Size: 3.95 x 5.0 x 1.9 cm* Operating Range: Up to 100 feet line of sight* Operating Temp.: -10C~ 60C (14F~140F)* Operating Voltage: 90 VAC~240 VAC, 50/60 Hz* Max. Loading: 15A
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Power off first, press Program Switch and power on, ZL7434-5 will send the Device Reset Locally Notification command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
To select the light type, 1 Wall Switch, 2 Wall Switches or wall switch with Light Indicator. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 | 1 or 2 Wall Switches |
2 | 1 Wall Switch with Light Indicator(factory default). |
If customer chose 1 or 2 wall switches, then they have also select switch button type. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | With common on/off type switch button used(factory default). |
2 | With momentary type switch button used. |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | 02 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15120003 |
Z-Wave Product Id | 0x0109.0x200C.0x0C06 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |