Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZL 7435EU-5 to your controller.To get in the inclusion mode, the distance between module and controller is suggested to be in one meter. Press 3 times within 2 seconds or turn on the wall switch 3 times within 2 seconds (or press toggle switch 3 times) to be included.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

* Super Mini Size: 39.5x 50 x 19 mm* Operating Range: Up to 100 feet line of sight* Operating Temp.: -15C~ 60C (5F~140F)* Operating Voltage: 100VAC~240VAC* Resistive Load:550W110 VAC 1100W220 VAC

Reset to factory default Factory Default Reset: Power off first, press Program Switch and power on till 10 seconds, ZL7435EU-5 will send the Device Reset Locally Notification command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
Inclusion For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZL 7435EU-5 to your controller.To get in the inclusion mode, the distance between module and controller is suggested to be in one meter. Press 3 times within 2 seconds or turn on the wall switch 3 times within 2 seconds (or press toggle switch 3 times) to be included.
Exclusion For Exclusion from (removing from) a network: Put the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZL 7435EU-5 from your controller. Press 3 times within 2 seconds or turn on the wall switch 3 times within 2 seconds (or press toggle switch 3 times) to be excluded.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Button Mode Switching

This parameter sets the mode for the wall switch inputs.
Size: 1 Byte, Default Value: 0

Setting Description
0 Switch Mode (Default)
1 Toggle Mode

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 02
Z-Wave Version 6.51.06
Certification ID ZC10-15110013
Z-Wave Product Id 0x0109.0x2017.0x1719
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch