Quickstart

This is a Siren for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZM 1601 to your controller. To get in the inclusion mode, the distance between siren and controller is suggested to be in one meter. Open the bracket and press the program switch of ZM 1601 for 1 second at least & release to be included. After setting, the LED Setting Light should go off,



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Features:*Loud audible alarm>105dB@1 meter*LED strobe lighting*Low battery detection*Siren for Battery Back-Up *100ft line of sight*LED Status Indicator*Operating temp: -15oC~60oC*Working Voltage: 6V*Dimensions: 116*77*40mm

Reset to factory default XXXResetDescription
Inclusion Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZM 1601 to your controller. To get in the inclusion mode, the distance between siren and controller is suggested to be in one meter. Open the bracket and press the program switch of ZM 1601 for 1 second at least & release to be included. After setting, the LED Setting Light should go off,
Exclusion Set up the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZM 1601 from your controller. Press the program switch of ZM 1601 for 1 second at least & release to be excluded. After setting The LED setting light will flash again
NIF XXXNIF
Wakeup removing the back cover of the ZM1601 to get into Awake mode
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline

Configuration Parameters

Parameter 1: Siren/Strobe mode

User can change value from 0 to 2 to turn either Siren sound, Strobe light, or both when triggered.
Size: 1 Byte, Default Value: 0

Setting Description
0 All Enable - Default
1 Siren Only
2 Strobe Only

Parameter 2: Alarm Auto Stop Time

User can change the duration of siren time when triggered.
Size: 1 Byte, Default Value: 0

Setting Description
0 30 seconds - Default
1 60 seconds
2 120 seconds
3 Will Not Automatically Stop

Technical Data

Hardware Platform ZM5202
Device Type Siren
Network Operation Listening Sleeping Slave
Firmware Version HW: 0.0 FW: 24.07
Z-Wave Version 6.51.06
Certification ID ZC10-15050013
Z-Wave Product Id 0x0109.0x2005.0x0508
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoSiren