Quickstart

This is a Routing Multilevel Sensor for XXXQFrequencyName. To run this device please insert fresh 2 * AAA batteries. To run this device please make sure the internal battery is fully charged.

A tripple click on the tampering switch behind the battery cover within 1.5 seconds will confirm standard inclusion and exclusion, double click confirms network wide inclusion. A single click on the same switch will wake up the device and keeps it awake for 10 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This product is a combination of a binary sensor with external switches, temperature sensor and a thermostat controlling a remote heating device by comparing the target temperature set with the measured temperature. The three functions can be used in parallel or independent of each other. The temperature sensor has a high accuracy +/- 0.2 K. The device is battery operated and can be placed on every flat surface either using screws or double sides tape.

Installation

The devices cover can be mounted on every flat surface either using two screws or strong double sides type. Insert both the batteries (2 x AAA) into the battery case while paying attention to the indicated plus (+) / minus (-) poles. The MTemp can now be mounted. The device itself is then just pushed on the cover. Make sure the dry input terminals match with the little spacing on the edge of the cover part.

Attention: The electronic circuit of the MTemp can be damaged in the case of wrong insertion of batteries.

Product Usage

The temperature sensor function (communication pattern 3) can be used without any further installation or configuration. The binary sensor function is available on the two terminal blocks inside the device. Please wire these terminals to the external switch that can be used. Beware: You must not power the two terminals. They are only connected with an external switch that is connecting the two wires or not. Switching the binary input can be used to control a wireless actor using Z-Wave commands (communication pattern 4).

The device can be used as a room thermostat. This function monitors the measured temperature against a desired temperature set point or a temperature range defined by a lower and an upper temperature trigger. The setpoint temperature can be set wirelessly using a Z-Wave command (Command Class Temperature Setpoint) MTemp will send on and off commands to a wirelessly controlled heating device (communication pattern 4) to keep the temperature within the desired range. Please refer to the description of the configuration parameters 1,2,4 and 5 for more information how to control wireless devices and how to set a desired temperature range.

To gain higher accuracy with the temperature sensor the device can be calibrated.

Reset to factory default XXXResetDescription
Inclusion

Once the controller is turned into standard inclusion mode tripple click the tamper switch will include the device. In case the controller is in network wide inclusion mode a double click will confirm inclusion. In case of doubt about the type of inclusion please assume standard inclusion.

Exclusion

Once the controller is turned into standard inclusion mode tripple click the tamper switch will include the device. In case the controller is in network wide inclusion mode a double click will confirm inclusion. In case of doubt about the type of inclusion please assume standard inclusion.

NIF

A single click on the tampering switch behind the battery cover will send out a Node Information Frame.

Wakeup

MTemp is awake right after inclusion for 2.5 seconds allowing the controller to perform certain configuration. It is possible to manually wake up the device by pushing the tamper switch. MTemp will accept wakeup intervals between 4 minutes and 180 days.

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
3 5 Nodes to receive updates on thermostat set point change and binary reports
2 5 Nodes to be controlled by thermostat
1 5 Nodes to be switched on/off on dry contacts switch

Configuration Parameters

Parameter 1: Binary sensor active

defines of the binary sensor is active
Size: 1 Byte, Default Value: 00

Setting Description
00 Off
ff On

Parameter 2: Binary sensor mode

defines the command sent when the binary sensor is triggered
Size: 1 Byte, Default Value: 00

Setting Description
00 Basic On on connected, Basic Off on diconnected
ff Basic Off on connected, Basic On on diconnected

Parameter 3: Send Unsolicited temperature report

Threshold temperature to send unsolicited report. 10 = 1 u00b0C
Size: 1 Byte, Default Value: 0a

Setting Description
00 Disabled
05 - 32 in 0.1 u00b0C

Parameter 4: Maximum deviation for thermostat

Maximum deviation (threshold) of temperature from set point before switching on/off cooling/heating for thermostat. 10 = 1 u00b0C
Size: 1 Byte, Default Value: 0a

Setting Description

Parameter 5: Repeat thermostat ON

Repeat thermostat events (switch ON events only) periodically
Size: 1 Byte, Default Value: 00

Setting Description
00 Send only once
01 - ff each Nth wakeup time

Parameter 6: Unsolicited temperature report period

period for unsolicited send the temperature report. 0 = Off
Size: 1 Byte, Default Value: 0f

Setting Description
00 Off
01 - ff each Nth wakeup time

Parameter 7: Temperature shift

Threshold correction. For positive value 10 = 1 u00b0C, for negative value x = 256 - (Tu00b0C * 10). Example, if need shift -2u00b0C, value calculate: 256 - (2 * 10) = 236.
Size: 1 Byte, Default Value: 00

Setting Description
00 Disabled
7f - ff in 0.1 u00b0C
00 - 7f in 0.1 u00b0C

Parameter 30: Send unsolicited Battery Report on Wake Up


Size: 1 Byte, Default Value: 00

Setting Description
00 No
01 To wakeup node
02 To broadcast

Technical Data

Dimensions 0.0330000x0.0570000x0.0180000 mm
Weight 20 gr
Hardware Platform ZM3102
Battery Type 2 * AAA
Device Type Routing Multilevel Sensor
Generic Device Class Multilevel Sensor
Specific Device Class Routing Multilevel Sensor
Firmware Version 02.01
Z-Wave Version 03.43
Z-Wave Product Id 0115.0201.0001
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeRouting Multilevel Sensor