Push the "Include" button behind the slider on the back side 3 times includes the device into an existing the Z-Wave network. The device can not act as primary network controller.
The Z-Wave.Me Remote controls Z-Wave actuators such as dimmers, switches, thermostats or motor controls for blinds or jalousies and it can activate scenes in central gateways or any other Z-Wave devices. Devices can be turned on and off but dimmers and motor controls can also be turned into a desired dimming level to motor position by keeping a button pushed and releasing it. Although it is controlling other devices, the device can not act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters 11-21:
10 pair of buttons - illuminated by blue light when operated - allow to control up to 10 control groups (either association groups or scenes)
This Remote Control has 10 different button groups to control 10 different devices or groups of devices.
Operating modes for direct device control:
The devices supports 8 different operating modes for these groups - this means the kind of command sent out when pushing a button. Operating modes either directly control other devices or they issue various scene activation commands to a central controller. Operating modes for direct device control are:
Example: Clicking/double clicking the button will issue scene triggers, scene 11 (button 1 click, event on), scene 12 (button double click 1, event off, single button control is used in this example)
Reset to factory default | XXXResetDescription |
Inclusion | For including the remote control into an existing the Z-Wave network do the following steps:
|
Exclusion | For excluding the remote control into an existing the Z-Wave network do the following steps:
|
NIF | Pressing the |
Wakeup | Pressing the "INCL." button for three times will wake up the device. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline. Send to controller battery level and WakeUp Notification |
2 | 5 | The buttons of group u21161 |
3 | 5 | The buttons of group u21162 |
4 | 5 | The buttons of group u21163 |
5 | 5 | The buttons of group u21164 |
6 | 5 | The buttons of group u21165 |
7 | 5 | The buttons of group u21166 |
8 | 5 | The buttons of group u21167 |
9 | 5 | The buttons of scene u21161 |
10 | 5 | The buttons of scene u21162 |
11 | 5 | The buttons of scene u21163 |
12 | 5 | The buttons of All On/Off |
This parameter defines the command to be sent to devices of control group u21161 when the related button is pressed (association group 2) Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control group u21162 when the related button is pressed (association group 3) Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control group u21163 when the related button is pressed (association group 4) Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control group u21164 when the related button is pressed (association group 5) Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control group u21165 when the related button is pressed (association group 6) Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control group u21166 when the related button is pressed (association group 7) Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control group u21167 when the related button is pressed (association group 8) Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control scene group u21161 when the related button is pressed (association group 9) Size: 1 Byte, Default Value: 04
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control scene group u21162 when the related button is pressed (association group 10) Size: 1 Byte, Default Value: 04
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control scene group u21163 when the related button is pressed (association group 11) Size: 1 Byte, Default Value: 04
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
This parameter defines the command to be sent to devices of control group All On/Off when the related button is pressed (association group 12) Size: 1 Byte, Default Value: 03
Setting | Description |
---|---|
00 | Disabled |
01 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
02 | Switch On/Off only (send Basic Set) |
03 | Switch All |
04 | Send Scenes |
05 | Send Preconfigured Scenes |
Size: 1 Byte, Default Value: ff
Setting | Description |
---|---|
01 | Switch off only |
02 | Switch on only |
ff | Switch all on and off |
Dimensions | 0.0500000x0.1720000x0.0220000 mm |
Weight | 140 gr |
Hardware Platform | ZM3102 |
EAN | 0019962007101 |
Battery Type | 4 * AAA |
Firmware Version | 01.01 |
Z-Wave Version | 03.43 |
Z-Wave Product Id | 0115.1000.0300 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |