Quickstart

This is a Z-Wave Device for XXXQFrequencyName. To run this device please insert fresh 4 * AAA batteries. To run this device please make sure the internal battery is fully charged.

 Push the "Include" button behind the slider on the back side 3 times includes the device into an existing the Z-Wave network. The device can not act as primary network controller.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Z-Wave.Me Remote controls Z-Wave actuators such as dimmers, switches, thermostats or motor controls for blinds or jalousies and it can activate scenes in central gateways or any other Z-Wave devices. Devices can be turned on and off but dimmers and motor controls can also be turned into a desired dimming level to motor position by keeping a button pushed and releasing it. Although it is controlling other devices, the device can not act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters 11-21:

  1. Direct control of associated devices
  2. Control of all devices in the Z-Wave network
  3. Simple and enhanced scene activation

10 pair of buttons - illuminated by blue light when operated - allow to control up to 10 control groups (either association groups or scenes)

Product Usage

This Remote Control has 10 different button groups to control 10 different devices or groups of devices.

Operating modes for direct device control:

The devices supports 8 different operating modes for these groups - this means the kind of command sent out when pushing a button. Operating modes either directly control other devices or they issue various scene activation commands to a central controller. Operating modes for direct device control are:

  • Direct Control of associated devices with On/Off/Dim commands (parameter 11...21 = 1). Devices are controlled using Basic Set On/Off commands and SwitchMultilevel Dim Start/Stop. This mode implements communication pattern 7. Each button of the button group has different functions:
    • ,On" - short click: turn on device(s)
    • ,On" - pushed: dim up light or wind up jalousie until button is released
    • ,Off" - short click: turn off device(s)
    • ,Off" - pushed: dim down light or wind down jalousie until button is released
    • Status: Call the status of the device controlled. Blue LED indicated "on", red LED indicates "off". A blinking LED indicated that different devices controlled by this button group have different switching states.
  • Direct Control of associated devices with only On/Off commands (parameter 11...21 = 2). Devices are controlled using only Basic Set On/Off commands. On dimming Up event On is sent, on dimming Down Off is sent. This mode also implements communication pattern 7.
  • Switch All commands (parameter 11...21 = 3) In this mode a all neighbouring devices will receive SwitchAll Set On/Off command and interpret it according to their membership in SwitchAll groups. This mode implements communication pattern 7.
Operating modes for scene activation are:
  • Direct Activation of preconfigured scenes (parameter 11...21 = 5) This mode causes the button of the groups to send out the number of the group (1..10) as scene activation command and implements communication patterns 6 and 7.
  • Scene Activation in IP Gateway (parameter 11...21 = 4) If configured correctly the buttons can trigger a scene in a gateway. The scene number triggered is a combination of the group number and the action performed on the button and has always two digits. The group number defines the upper digit of the scene number, the action the lower digit. The following actions are possible:
    • 1 = On
    • 2 = Off
    • 3 = Dim Up Start
    • 4 = Dim Down Start
    • 5 = Dim Up Stop
    • 6 = Dim Down Stop

    Example: Clicking/double clicking the button will issue scene triggers, scene 11 (button 1 click, event on), scene 12 (button double click 1, event off, single button control is used in this example)

Reset to factory default XXXResetDescription
Inclusion

For including the remote control into an existing the Z-Wave network do the following steps:

  • Bring your primary controller into inclusion mode.
  • For Inclusion press the "Inclusion" button 3 times. The LED will flash green for a moment for confirmation.
Exclusion

For excluding the remote control into an existing the Z-Wave network do the following steps:

  • Bring your primary controller into exclusion mode.
  • For Exclusion press the "Exclusion" button for 5 secs. The LED will flash green for a moment for confirmation.
NIF

Pressing the

Wakeup

Pressing the "INCL." button for three times will wake up the device.

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline. Send to controller battery level and WakeUp Notification
2 5 The buttons of group u21161
3 5 The buttons of group u21162
4 5 The buttons of group u21163
5 5 The buttons of group u21164
6 5 The buttons of group u21165
7 5 The buttons of group u21166
8 5 The buttons of group u21167
9 5 The buttons of scene u21161
10 5 The buttons of scene u21162
11 5 The buttons of scene u21163
12 5 The buttons of All On/Off

Configuration Parameters

Parameter 10: Command to Control Group u21161 (association group 2)

This parameter defines the command to be sent to devices of control group u21161 when the related button is pressed (association group 2)
Size: 1 Byte, Default Value: 01

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 11: Command to Control Group u21162 (association group 3)

This parameter defines the command to be sent to devices of control group u21162 when the related button is pressed (association group 3)
Size: 1 Byte, Default Value: 01

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 12: Command to Control Group u21163 (association group 4)

This parameter defines the command to be sent to devices of control group u21163 when the related button is pressed (association group 4)
Size: 1 Byte, Default Value: 01

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 13: Command to Control Group u21164 (association group 5)

This parameter defines the command to be sent to devices of control group u21164 when the related button is pressed (association group 5)
Size: 1 Byte, Default Value: 01

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 14: Command to Control Group u21165 (association group 6)

This parameter defines the command to be sent to devices of control group u21165 when the related button is pressed (association group 6)
Size: 1 Byte, Default Value: 01

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 15: Command to Control Group u21166 (association group 7)

This parameter defines the command to be sent to devices of control group u21166 when the related button is pressed (association group 7)
Size: 1 Byte, Default Value: 01

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 16: Command to Control Group u21167 (association group 8)

This parameter defines the command to be sent to devices of control group u21167 when the related button is pressed (association group 8)
Size: 1 Byte, Default Value: 01

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 17: Command to Control Scene u21161 (association group 9)

This parameter defines the command to be sent to devices of control scene group u21161 when the related button is pressed (association group 9)
Size: 1 Byte, Default Value: 04

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 18: Command to Control Scene u21162 (association group 10)

This parameter defines the command to be sent to devices of control scene group u21162 when the related button is pressed (association group 10)
Size: 1 Byte, Default Value: 04

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 19: Command to Control Scene u21163 (association group 11)

This parameter defines the command to be sent to devices of control scene group u21163 when the related button is pressed (association group 11)
Size: 1 Byte, Default Value: 04

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 20: Command to Control group All On/Off (association group 12)

This parameter defines the command to be sent to devices of control group All On/Off when the related button is pressed (association group 12)
Size: 1 Byte, Default Value: 03

Setting Description
00 Disabled
01 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
02 Switch On/Off only (send Basic Set)
03 Switch All
04 Send Scenes
05 Send Preconfigured Scenes

Parameter 21: Send the following Switch All commands


Size: 1 Byte, Default Value: ff

Setting Description
01 Switch off only
02 Switch on only
ff Switch all on and off

Technical Data

Dimensions 0.0500000x0.1720000x0.0220000 mm
Weight 140 gr
Hardware Platform ZM3102
EAN 0019962007101
Battery Type 4 * AAA
Firmware Version 01.01
Z-Wave Version 03.43
Z-Wave Product Id 0115.1000.0300
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeZ-Wave Device