Quickstart

This is a Siren for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
N/A



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeon Labs Doorbell supports playing MP3 music files with a press of this doorbell. It has a 128MB flash memory that can store up to 800 ringtones. The volume can be adjusted manually via short press on the Volume Button, also you can switch the doorbell sound to the next via long press on the Volume Button. You may change/update your doorbell ringtone at any point in time you want by connecting your Doorbell to your PC to update the sound track on your Doorbells flash memory.There is a small Wireless Button, which can trigger the doorbell on the other side of the wall to play the selected doorbell music when pressed.It also act as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary listening Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable.
Inclusion N/A
Exclusion N/A
NIF XXXNIF
Wakeup N/A
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the Doorbell is received the commands sent by controller to be turned on or off, the Doorbell will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80.
2 5 When the Doorbell receives the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set commands from main controller. it will forward the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set to associated nodes in Group 2.

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.

Configuration Parameters

Parameter 10: Define the function ofButton- or Button+.

This parameter is used to define the function of Button- or Button+.
Size: 1 Byte, Default Value: 0

Setting Description
0 Button- is defined to be the control item of Previous. Button+ is defined to be the control item of Next.
1 Button- is defined to be the control item of Next. Button+ is defined to be the control item of Previous.

Parameter 11: Define the function of Button- and Button+ when pressing it once and long pressing it.

This parameter is used to define the function of Button- and Button+ when pressing it once and long pressing it.
Size: 1 Byte, Default Value: 0

Setting Description
0 Pressing it once, which will change the volume. Long pressing it, which will change the default ringtone.
1 Pressing it once, which will change the default ringtone. Long pressing it, which will change the the volume.

Parameter 2: Set the repetitions for playing doorbell ringtone.

This parameter is used to set the repetitions for playing doorbell ringtone.Note: If the time of playing doorbell ringtone is more than 20 seconds, the volume of ringtone will reduce to silence no matter how many repetitions of doorbell ringtone are set.
Size: 1 Byte, Default Value: 2

Setting Description
1 - 100 the range of repetition is 1 to 100.

Parameter 241: Pair the Wireless Button with Doorbell

This parameter is used to pair the Wireless Button with Doorbell.Note:1. This procedure should only be used when the complimentary Wireless Button is missing or inoperable and you have another new Wireless Button that would be paired with your Doorbell.2. When the pairing is started, the blue led will blink slowly, at this time, you just need to press the Wireless Button once. If the blue led change to be solid, which means the pairing is successful. Otherwise, repeat the steps.
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Start the Wireless Button pairing mode.

Parameter 252: Enable/Disable Lock Configuration

This parameter is used to enable/disable Lock all configuration parameters.(0 =disable, 1 = enable)
Size: 1 Byte, Default Value: 0

Setting Description
0 All configuration parameters are configurable.
1 All configuration parameters are not configurable (Locked).

Parameter 255: Reset to default factory setting

This parameter is used to reset product to default factory setting. (There are just 2 values can be used).
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.
1 Resets all configuration parameters to default setting.

Parameter 42: Get the battery status of Wireless Button.

This parameter is used to get the battery status of Wireless Button.Note: Just need to send the configuration parameter 42 Get command to Doorbell. The configuration report value will be the status of battery.
Size: 1 Byte, Default Value: 0

Setting Description
0 The current battery status is normal battery level.
255 The current battery status is low battery level.

Parameter 5: Set the default doorbell ringtone.

This parameter is used to set the default doorbell ringtone.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 100 To set which ringtone number is the default ringtone.

Parameter 6: Select a ringtone to play.

This parameter is used to select a ringtone to play, which is onlyfor customer testing the doorbell ringtone.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 100 Play the specified ringtone.
0 Stop playing.

Parameter 7: Control items

This parameter is used to implement the control items.
Size: 1 Byte, Default Value: 0

Setting Description
1 Implement the control item of Play.
2 Implement the control item of Stop.
3 Implement the control item of Pause.
4 Implement the control item of Next.
5 Implement the control item of Previous.

Parameter 8: Set the volume of ringtone.

This parameter is used to set the volume of ringtone.The volume has 10 levels can be set. Value=10, which is the max volume.Value=0, which is the min volume.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 10 The max volume is 10, the min volume is 0.

Parameter 80: Enable/Disable to send notifications to associated devices to associated devices.

This parameter is used to enable/disable to send notifications to associated devices (in Group 1) when the state of Doorbell Gen5s load is changed. (0=Send nothing, 1=Send hail CC, 2=Send basic report CC).
Size: 1 Byte, Default Value: 0

Setting Description
2 Send BASIC Report Command
0 Send Nothing (Disabled)
1 Send HAIL Command

Parameter 81: Enable/disable to send notification to associated devices.

This parameter is used to enable/disable to send notification to associated devices (In group 1) just only when the Wireless Button's battery is in low battery status.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Technical Data

Hardware Platform ZM5101
Device Type Siren
Network Operation Always On Slave
Firmware Version HW: 38 FW: 1.11
Z-Wave Version 6.51.06
Certification ID ZC10-15060002
Z-Wave Product Id 0x0086.0x0104.0x0038
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoSiren