This is a
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find on the product's housing.
Aeon Labs Garage Door Controller is a smart and wireless Garage Door Control system, you can control the garage door to open, close, or stop moving via wireless signal on your gateway client or phone application.The Garage Door Controller allows you to configure different alarm sounds to indicate the doors action. Each action alarm sound can be customized. To change or update new alarm sounds for the Garage Door Controller, connect the Garage Door Controller to your PC host with a USB cable and download your sound files to the flash memory (128 MB) of the Garage Door Controller.It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. It is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.
Reset to factory default | Press and hold the Z-Wave button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable. |
Inclusion | Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find on the product's housing. |
Exclusion | Turn the primary controller of Z-Wave network into exclusion mode, short press the products Z-Wave button that you can find on the product's housing. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus LifelineThe Hail CC, Barrier operator report CC can be sent to the associated nodes in this group. |
2 | 5 | Forward the Basic Set, Switch Binary Set commands to associated nodes in Group 2 when the Garage Door Controller receives the Basic Set, Switch Binary Set commands from the main controller. |
Pair the Sensor with Garage Door Controller Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1431655681 | trigger to start the pairing of Sensor |
Enable/disable to lock the configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Reset rhe Garage Door Controller Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset all configuration parameters to factory default settings |
1431655765 | Reset the device to factory default and excluded from the network |
Configure the default startup ringtone. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable the startup ringtone. |
1 - 127 | enable and select a startup ringtone for the Garage Door Controller. |
Sensor Calibration. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Garage Door Controller enters calibration mode |
Set the timeout of all calibration steps for the Sensor. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 127 | The time unit is second and time range is 1 to 127 seconds |
Get the numbers of alarm music. Note: this parameter is a get- only parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Get the numbers of alarm music |
Configure the alarm mode when the garage door is opening. Size: 4 Byte, Default Value: 133121
Setting | Description |
---|---|
0 | disable the alarm prompt. |
1 | enable the alarm prompt. |
256 - 266 | configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels |
65536 - 65636 | configure the alarm sound |
16777216 - 16777226 | configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10. |
Configure the alarm mode when the garage door is closing Size: 4 Byte, Default Value: 134416385
Setting | Description |
---|---|
0 | disable the alarm prompt. |
1 | enable the alarm prompt. |
256 - 266 | configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels |
65536 - 65636 | configure the alarm sound |
16777216 - 16777226 | configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10. |
Configuration alarm mode when the garage door is in u0022unknownu0022 position Size: 4 Byte, Default Value: 100927488
Setting | Description |
---|---|
0 | disable the alarm prompt. |
1 | enable the alarm prompt. |
256 - 266 | configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels |
65536 - 65636 | configure the alarm sound |
16777216 - 16777226 | configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10. |
Configure the alarm mode when the garage door is in closed position Size: 1 Byte, Default Value: 33883392
Setting | Description |
---|---|
0 | disable the alarm prompt. |
1 | enable the alarm prompt. |
256 - 266 | configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels |
65536 - 65636 | configure the alarm sound |
16777216 - 16777226 | configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10. |
Configuration Report for the tamper switch state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Sensor is not removed |
15 | Sensor is removed |
Configuration report for the battery state of Sensor Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | battery power is much more. |
15 | battery power of Sensor is in low battery. |
Start playing or Stop playing the ringtone Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-1 | stop playing ringtone |
1 - 100 | start playing the ringtone that you selected. |
Test the volume of the current ringtone Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 10 | the volume level 1 to level 10. |
Get the environment temperature Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 500 | Rang is 0 to 500 (0 to 50.0). |
Define the function of Button- or Button+ Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | short pressing the Button +/- will be used to adjust the volume of sound. Long pressing the Button +/- will be used to switch the sound to the next. |
1 | short pressing the Button +/- will be used to switch the sound to the next. Long pressing the Button +/- will be used to adjust the volume of sound |
It will send the Hail CC/configuration report CC when the state of garage door is changed Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 | send Hail CC |
2 | send Barrier operator report CC |
Hardware Platform | ZM5101 |
Device Type | Barrier Operator |
Network Operation | Always On Slave |
Firmware Version | HW: 62 FW: 11.11 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17085731 |
Z-Wave Product Id | 0x012A.0x0103.0x003E |
Supported Notification Types | Access Control |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |