Quickstart

This is a secure Barrier Operator for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find on the product's housing.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeon Labs Garage Door Controller is a smart and wireless Garage Door Control system, you can control the garage door to open, close, or stop moving via wireless signal on your gateway client or phone application.The Garage Door Controller allows you to configure different alarm sounds to indicate the doors action. Each action alarm sound can be customized. To change or update new alarm sounds for the Garage Door Controller, connect the Garage Door Controller to your PC host with a USB cable and download your sound files to the flash memory (128 MB) of the Garage Door Controller.It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. It is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.

Reset to factory default Press and hold the Z-Wave button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find on the product's housing.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Z-Wave button that you can find on the product's housing.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus LifelineThe Hail CC, Barrier operator report CC can be sent to the associated nodes in this group.
2 5 Forward the Basic Set, Switch Binary Set commands to associated nodes in Group 2 when the Garage Door Controller receives the Basic Set, Switch Binary Set commands from the main controller.

Configuration Parameters

Parameter 241: Pair the Sensor with Garage Door Controller

Pair the Sensor with Garage Door Controller
Size: 4 Byte, Default Value: 0

Setting Description
1431655681 trigger to start the pairing of Sensor

Parameter 252: Enable/disable to lock the configuration parameters.

Enable/disable to lock the configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 255: Reset rhe Garage Door Controller

Reset rhe Garage Door Controller
Size: 4 Byte, Default Value: 0

Setting Description
1 Reset all configuration parameters to factory default settings
1431655765 Reset the device to factory default and excluded from the network

Parameter 32: Configure the default startup ringtone.

Configure the default startup ringtone.
Size: 1 Byte, Default Value: 1

Setting Description
0 disable the startup ringtone.
1 - 127 enable and select a startup ringtone for the Garage Door Controller.

Parameter 34: Sensor Calibration.

Sensor Calibration.
Size: 1 Byte, Default Value: 0

Setting Description
1 Garage Door Controller enters calibration mode

Parameter 35: Set the timeout of all calibration steps for the Sensor.

Set the timeout of all calibration steps for the Sensor.
Size: 1 Byte, Default Value: 60

Setting Description
1 - 127 The time unit is second and time range is 1 to 127 seconds

Parameter 36: Get the numbers of alarm music.

Get the numbers of alarm music. Note: this parameter is a get- only parameter.
Size: 1 Byte, Default Value: 0

Setting Description
1 Get the numbers of alarm music

Parameter 37: Configure the alarm mode when the garage door is opening.

Configure the alarm mode when the garage door is opening.
Size: 4 Byte, Default Value: 133121

Setting Description
0 disable the alarm prompt.
1 enable the alarm prompt.
256 - 266 configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels
65536 - 65636 configure the alarm sound
16777216 - 16777226 configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10.

Parameter 38: Configure the alarm mode when the garage door is closing

Configure the alarm mode when the garage door is closing
Size: 4 Byte, Default Value: 134416385

Setting Description
0 disable the alarm prompt.
1 enable the alarm prompt.
256 - 266 configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels
65536 - 65636 configure the alarm sound
16777216 - 16777226 configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10.

Parameter 39: Configuration alarm mode when the garage door is in "unknown" position

Configuration alarm mode when the garage door is in u0022unknownu0022 position
Size: 4 Byte, Default Value: 100927488

Setting Description
0 disable the alarm prompt.
1 enable the alarm prompt.
256 - 266 configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels
65536 - 65636 configure the alarm sound
16777216 - 16777226 configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10.

Parameter 40: Configure the alarm mode when the garage door is in closed position

Configure the alarm mode when the garage door is in closed position
Size: 1 Byte, Default Value: 33883392

Setting Description
0 disable the alarm prompt.
1 enable the alarm prompt.
256 - 266 configure the volume of alarm sound (there are 10 levels, the min volume is 1 level and the max volume is 10 levels
65536 - 65636 configure the alarm sound
16777216 - 16777226 configure the frequency of blinking for the Alarm LED, there are 10 levels that 1 to10 level, the minimum frequency is level 1 and the max frequency is level 10.

Parameter 41: Configuration Report for the tamper switch state

Configuration Report for the tamper switch state
Size: 1 Byte, Default Value: 0

Setting Description
0 Sensor is not removed
15 Sensor is removed

Parameter 42: Configuration report for the battery state of Sensor

Configuration report for the battery state of Sensor
Size: 1 Byte, Default Value: 0

Setting Description
0 battery power is much more.
15 battery power of Sensor is in low battery.

Parameter 43: Start playing or Stop playing the ringtone

Start playing or Stop playing the ringtone
Size: 1 Byte, Default Value: 0

Setting Description
-1 stop playing ringtone
1 - 100 start playing the ringtone that you selected.

Parameter 44: Test the volume of the current ringtone

Test the volume of the current ringtone
Size: 1 Byte, Default Value: 0

Setting Description
1 - 10 the volume level 1 to level 10.

Parameter 45: Get the environment temperature

Get the environment temperature
Size: 2 Byte, Default Value: 0

Setting Description
0 - 500 Rang is 0 to 500 (0 to 50.0).

Parameter 47: Define the function of Button- or Button+

Define the function of Button- or Button+
Size: 1 Byte, Default Value: 0

Setting Description
0 short pressing the Button +/- will be used to adjust the volume of sound. Long pressing the Button +/- will be used to switch the sound to the next.
1 short pressing the Button +/- will be used to switch the sound to the next. Long pressing the Button +/- will be used to adjust the volume of sound

Parameter 80: It will send the Hail CC/configuration report CC when the state of garage door is changed

It will send the Hail CC/configuration report CC when the state of garage door is changed
Size: 1 Byte, Default Value: 2

Setting Description
1 send Hail CC
2 send Barrier operator report CC

Technical Data

Hardware Platform ZM5101
Device Type Barrier Operator
Network Operation Always On Slave
Firmware Version HW: 62 FW: 11.11
Z-Wave Version 6.51.06
Certification ID ZC10-17085731
Z-Wave Product Id 0x012A.0x0103.0x003E
Supported Notification Types Access Control
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoBarrier Operator