Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find on the product's housing.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeon Labs Garage Door Controller is a smart and wireless Garage Door Control system, you can control the garage door to open, close, or stop moving via wireless signal on your gateway client or phone application.The Garage Door Controller allows you to configure different alarm sounds to indicate the doors action. Each action alarm sound can be customized. To change or update new alarm sounds for the Garage Door Controller, connect the Garage Door Controller to your PC host with a USB cable and download your sound files to the flash memory (128 MB) of the Garage Door Controller.It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. It is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and hold the Z-Wave button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is missing or inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the Garage Door controller is received the commands sent by controller to be turned on or off, the Garage Door controller will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80. |
2 | 5 | When the Garage Door Controller receives the Basic Set, Switch Binary Set,commands from main controller. it will forward the Basic Set, Switch Binary Set to associated nodes in Group 2. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter is used to pair the Sensor with Garage Door Controller.Note:1. This procedure should only be used when the complimentary Sensor is missing or inoperable and you have another new Sensor that would be paired with your Garage Door Controller.2. When the pairing is started, the Network LED will blink slowly, at this time, you just need to press the Temper Switch back of the Sensor once. If the Network LED change to be solid, which means the pairing is successful. Otherwise, repeat the steps. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1431655681 | Start the Sensor pairing mode. |
This parameter is used to enable/disable Lock all configuration parameters.(0 =disable, 1 = enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | All configuration parameters are configurable. |
1 | All configuration parameters are not configurable (Locked). |
This parameter is used to reset product to default factory setting. (There are just 2 values can be used). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset all configuration parameters to default setting. |
1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. |
This parameter is used to set the default startup ringtone for the Garage Door Controller. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable the startup ringtone. |
1 - 100 | Enable and select a startup ringtone for the Garage Door Controller. |
This parameter is used to calibrate the Sensor.Calibration Steps:1. Let the garage door move to full close position. 2. Send this parameter (0x22) with value=1 to Garage Door Controller.3. Let the garage door move to full open position.4. Let the garage door move to full close position after the step 3 is completed.After the step 4 is completed, all calibration steps are complete. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Enable calibration. |
This parameter is used to set the timeout of Sensor calibration in parameter 34.The unit is second. Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 32767 | Set the timeout of calibration |
This parameter is used to get the the number of alarm music that are stored in the flash memory card.Note: this parameter only will use the configure get command to get the number of alarm music. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Get the number of alarm music. |
This parameter is used to set an alarm mode when the garage door is opening.. Size: 4 Byte, Default Value: 524560
Setting | Description |
---|---|
1 - 10 | Configure the flash frequency of the alarm LED, there are 10 levels can be set. |
16777215 | Disable the alarm mode. |
65535 - 65545 | Configure the volume of alarm sound, there are 10 levels can be set. |
256 - 356 | Select an alarm sound, there are 4 alarm sounds in the flash memory card can be selected. |
16777216 | Enable the alarm mode. |
This parameter is used to set the alarm mode when the garage door is closing. Size: 4 Byte, Default Value: 524806
Setting | Description |
---|---|
16777216 | Enable the alarm mode. |
1 - 10 | Configure the flash frequency of the alarm LED, there are 10 levels can be set. |
65535 - 65545 | Configure the volume of alarm sound, there are 10 levels can be set. |
16777215 | Disable the alarm mode. |
256 - 356 | Select an alarm sound, there are 4 alarm sounds in the flash memory card can be selected. |
This parameter is used to set the alarm mode when the garage door is in u0022Unknownu0022 position. Size: 4 Byte, Default Value: 525060
Setting | Description |
---|---|
1 - 10 | Configure the flash frequency of the alarm LED, there are 10 levels can be set. |
65535 - 65545 | Configure the volume of alarm sound, there are 10 levels can be set. |
16777215 | Disable the alarm mode. |
16777216 | Enable the alarm mode. |
256 - 356 | Select an alarm sound, there are 4 alarm sounds in the flash memory card can be selected. |
This parameter is used to set the alarm mode when the garage door is in closed position. Size: 4 Byte, Default Value: 525314
Setting | Description |
---|---|
16777216 | Enable the alarm mode. |
1 - 10 | Configure the flash frequency of the alarm LED, there are 10 levels can be set. |
256 - 356 | Select an alarm sound, there are 4 alarm sounds in the flash memory card can be selected. |
65535 - 65545 | Configure the volume of alarm sound, there are 10 levels can be set. |
16777215 | Disable the alarm mode. |
This parameter is used to report the state when the Sensor is installed on the garage door or removed from the garage door.Note:The state would be reported via configuration report CC. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The Sensor is installed on the garage door. |
15 | The Sensor is removed from the garage door. |
This parameter is used to report the battery state of Sensor. Note:The state would be reported via configuration report CC. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
15 | Battery is in low battery state. |
0 | Battery is in normal state. |
This parameter is used to audition or test the product's ringtone. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-1 | Stop playing the ringtone. |
1 - 100 | Start playing the ringtone that you select. |
This parameter is used to audition or test the product's ringtone volume. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 10 | There are 10 volume levelscan be set for testing. |
This parameter is used to get the temperature where near to your Garage Door Controller. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 500 | The available temperature range is 0 to 50 Celsius |
This parameter is used to define the function of Button- and Button+. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Pressing it once, the Button+ and Button- are defined to be the control item of Next and Previous. Press and hold it, the Button+ and Button- are defined to be used to increase and decrease the volume. |
0 | Pressing it once, the Button+ and Button- are defined to be used to increase and decrease the volume. Press and hold it, the Button+ and Button- are defined to be the control item of Next and Previous. |
This parameter is used to enable/disable to send notifications to associated devices (in Group 1) when the state of Doorbell Gen5s load is changed. (0=Send nothing, 1=Send hail CC, 2=Send barrier operator report CC). Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
2 | Send BARRIER OPERATOR Report Command |
0 | Send Nothing (Disabled) |
1 | Send HAIL Command |
Hardware Platform | ZM5101 |
Device Type | Secure Barrier Add-On |
Network Operation | Always On Slave |
Firmware Version | HW: 62 FW: 1.11 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15090011 |
Z-Wave Product Id | 0x0086.0x0203.0x003E |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |