Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
TheAeotecbyAeonLabsMultiSensorGen5lookslike a motion sensor and itacts like one too.But its also so much more. Installing this 1 piece of Z-Wave technology isthe same as installing 4pieces ofZ-Wavetechnology.Your home control network will immediately understand motion, temperature, humidity and light readings wherever Multisensor installed. Those intelligent readings will equate to intelligenceautomation. And intelligent automation will give you the perfect, smart home.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Press and hold the Z-Wave button for 3 seconds will trigger sending the Wake up notification command. If press the Z-Wave button 3 times, the MultiSensor will wake up for 10 minutes.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.The Motion sensor, Humidity sensor, thermometer and light sensor reports will be sent to the associated nodes in Group 1. |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find in the back of the product.
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
Turn the primary controller of Z-Wave network into exclusion mode, short press the products Z-Wave button that you can find in back of the product.
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter is used to configure to send the Humidity sensor, thermometer, light sensor and battery reports automatically in Report group 1.Note: The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, the temperature sensor report is the value 32 and the battery report is the value 1, so setting parameter 101 to a value of 33 will result in both temperature sensor report and battery report to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 255
Setting | Description |
---|---|
64 | The humidity sensor report is selected. |
128 | The light sensor report is selected. |
1 | The battery report is selected. |
32 | The temperature sensor report is selected. |
This parameter is used to configure to send the Humidity sensor, thermometer, light sensor and battery reports automatically in Report group 2.Note: The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, the temperature sensor report is the value 32 and the battery report is the value 1, so setting parameter 102 to a value of 33 will result in both temperature sensor report and battery report to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
128 | The light sensor report is selected. |
1 | The battery report is selected. |
32 | The temperature sensor report is selected. |
64 | The humidity sensor report is selected. |
This parameter is used to configure to send the Humidity sensor, thermometer, light sensor and battery reports automatically in Report group 3.Note: The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, the temperature sensor report is the value 32 and the battery report is the value 1, so setting parameter 103 to a value of 33 will result in both temperature sensor report and battery report to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
32 | The temperature sensor report is selected. |
64 | The humidity sensor report is selected. |
128 | The light sensor report is selected. |
1 | The battery report is selected. |
This parameter is used to configure the interval time of the sensor report in Report group 1.The time unit is second. Size: 4 Byte, Default Value: 1800
Setting | Description |
---|---|
5 - 2678400 | The range of interval time is 5 to 2678400. |
This parameter is used to configure the interval time of the sensor report in Report group 2.The time unit is second. Size: 4 Byte, Default Value: 1800
Setting | Description |
---|---|
5 - 2678400 | The range of interval time is 5 to 2678400. |
This parameter is used to configure the interval time of the sensor report in Report group 3.The time unit is second. Size: 4 Byte, Default Value: 1800
Setting | Description |
---|---|
5 - 2678400 | The range of interval time is 5 to 2678400. |
This parameter is used to enable/disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.1. Value = 0, disable.2. Value =others, enable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. |
1 | Enable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. |
This parameter is used to enable/disable all configuration parameters to be locked.(0 =disable, 1 = enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable all configuration parameters to be locked. |
1 | Enable all configuration parameters to be locked. |
This parameter is used to reset product to default factory setting. (There are just 2 values can be used). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Resets all configuration parameters to default setting. |
1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. |
This parameter is used to set the timeout for the motion sensor.Note:(1), The time unit is second if the value range is in 1 to 255. (2), If the value range is in 256 to 15300, the time unit will be minute and its value should follow the below rules:a),Interval time =Value/60, if the interval time can be divided by 60 and without remainder.b), Interval time= (Value/60) +1, if the interval time can be divided by 60 and has remainder.(3), Other values will be ignored. Size: 2 Byte, Default Value: 240
Setting | Description |
---|---|
1 - 255 | The unit of timeout is second. |
256 - 15300 | The unit of timeout is minute. |
This parameter is used to enable/disable the function of motion sensor.1. Value=0, disable.2. Value=1, enable. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable the function of motion sensor. |
1 | Enable the function of motion sensor. |
This parameter is used to enable/disable the selective reporting only when measurements reach a certain threshold or percentage set in the parameter 41 to 44.This is used to reduce network traffic.(0 == disable, 1 == enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Enable the selective reporting. |
0 | Disable the selective reporting. |
Threshold change in temperature to induce an automatic report. Note:1. When the unit is Celsius, threshold=Value.2. When the unit is Fahrenheit, threshold=Value*1.8The accuracy is 0.1. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 65535 | Threshold of temperature. |
Threshold change in humidity to induce an automatic report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | Threshold of humidity |
Threshold change in luminance to induce an automatic report. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 1000 | Threshold of luminance |
Threshold change in battery level to induce an automatic report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | Threshold of battery level. |
This parameter is used to enable/disable to send the alarm report of low temperature(<-15)1, Value=0, disable.2, Value=1, enable(Note:The MultiSensor will report the Multi Level Temperature CC with the value=0xFFFF to controller if the current temperature is less than -15). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable to send the alarm report of low temperature(&amp;amp;amp;amp;amp;amp;amp;amp;lt;-15) |
1 | Enable to send the alarm report of low temperature(&amp;amp;amp;amp;amp;amp;amp;amp;lt;-15) |
This parameter is used to configure that which command would be sent when the motion sensor triggered.1. Value=1, send Basic Set CC.2. Value=2, send Sensor Binary Report CC. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
2 | Send Sensor Binary Report CC. |
1 | Send Basic Set CC. |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 4A FW: 1.02 |
Z-Wave Version | 6.51.01 |
Certification ID | ZC10-14120005 |
Z-Wave Product Id | 0x0086.0x0202.0x004A |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |