Aeon Labs Smart Switch Gen5 is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 16A current of resistive loads. It also acts as a repeater that forwards Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary listening Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world.
Reset to factory default | Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. |
Inclusion | N/A |
Exclusion | N/A |
NIF | XXXNIF |
Wakeup | N/A |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the switch is turned on or off using the action button, the switch will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80. |
2 | 5 | When the product receives a controlling Basic Set CC/Switch Binary Set CC/ Scene Activation Set CC, which if cause the products load state to be changed, which will lead to send the Basic Set CC/Switch Binary Set CC /Scene Activation Set CC to nodes in group 2. |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.
This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 4
Setting | Description |
---|---|
8 | Report Accumulated kWh |
2 | Report Instantaneous Current (Amperes) |
4 | Report Instantaneous Watts |
1 | Report Instantaneous Voltage |
This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 8
Setting | Description |
---|---|
1 | Report Instantaneous Voltage |
4 | Report Instantaneous Watts |
8 | Report Accumulated kWh |
2 | Report Instantaneous Current (Amperes) |
This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Report Instantaneous Voltage |
2 | Report Instantaneous Current (Amperes) |
4 | Report Instantaneous Watts |
8 | Report Accumulated kWh |
This parameter is used to set the interval time of sending report in Report Group 1. (The unit of time is second). Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used to set the interval time of sending report in Report Group 2. (The unit of time is second). Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used to set the interval time of sending report in Report Group 3. (The unit of time is second). Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used for customer to control the products load (e. g incandescent light) to blink with a certain time when you set this parameter and send this command to the load. Size: 2 Byte, Default Value: 3850
Setting | Description |
---|---|
0 - 255 | Specify the time that Smart Switch should blink, in seconds. |
256 - 32767 | Specifies the cycle of on/off, the unit of it is 0.1 second. |
This parameter is used to configure the partner ID. (0== Aeon Labs Standard Product, 1~255== others). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Aeon Labs Standard Product |
1 - 255 | Partner ID of Partner Product |
This parameter is used to enable/disable Lock all configuration parameters.(0 =disable, 1 = enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | All configuration parameters are configurable. |
1 | All configuration parameters are not configurable (Locked). |
This parameter is used to save the device tag, which will be written/ assigned in factory/ manufacturer. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32767 | Device Tag |
This parameter is used to reset product to default factory setting. (There are just 2 values can be used). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. |
1 | Resets all configuration parameters to default setting. |
This parameter is used for the overload protection, which means the load will be disconnected after 2 minutes when the current more than 16.2A. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Overload Protection Disabled |
1 | Overload Protection is Enabled |
This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Smart Switch Gen5s load is changed. (0=Send nothing, 1=Send hail CC, 2=Send basic report CC). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send Nothing (Disabled) |
1 | Send HAIL Command |
2 | Send BASIC Report Command |
This parameter is used to Enable/Disable the function of parameter 91 and 92 (1=Enabled, 0=Disabled). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Configuration Parameters 91 and 92 are Disabled |
1 | Configuration Parameters 91 and 92 are Enabled |
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage. Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100 percent. |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 64 FW: 1.08 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15070020 |
Z-Wave Product Id | 0x0086.0x001B.0x0048 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |