Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
N/A



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeon Labs Heavy Duty Smart Switch is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 40A current of resister loads. It also acts as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary listening Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion N/A
Exclusion N/A
NIF XXXNIF
Wakeup N/A
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the switch is turned on or off using the action button, the switch will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80.
2 5 When the product receives a controlling Basic Set CC/Switch Binary Set CC/ Scene Activation Set CC, which if cause the products load state to be changed, which will lead to send the Basic Set CC/Switch Binary Set CC /Scene Activation Set CC to nodes in group 2.

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.

Configuration Parameters

Parameter 101: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 4

Setting Description
8 Report Accumulated kWh
2 Report Instantaneous Current (Amperes)
4 Report Instantaneous Watts
1 Report Instantaneous Voltage

Parameter 102: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 8

Setting Description
1 Report Instantaneous Voltage
4 Report Instantaneous Watts
8 Report Accumulated kWh
2 Report Instantaneous Current (Amperes)

Parameter 103: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 0

Setting Description
1 Report Instantaneous Voltage
2 Report Instantaneous Current (Amperes)
4 Report Instantaneous Watts
8 Report Accumulated kWh

Parameter 111: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 1. (The unit of time is second).
Size: 4 Byte, Default Value: 300

Setting Description
0 - 268435456 Interval Seconds

Parameter 112: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 2. (The unit of time is second).
Size: 4 Byte, Default Value: 120

Setting Description
0 - 268435456 Interval Seconds

Parameter 113: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 3. (The unit of time is second).
Size: 4 Byte, Default Value: 120

Setting Description
0 - 268435456 Interval Seconds

Parameter 20: The load status after power on

This parameter is used for indicating the state of output load after re-power on.
Size: 1 Byte, Default Value: 0

Setting Description
0 The load state will back to the last state after power on.
1 The load state will always on after re-power on.
2 The load state will always off stare after re-power on.

Parameter 200: Partner ID

This parameter is used to configure the partner ID. (0== Aeon Labs Standard Product, 1~255== others).
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 255 Partner ID of Partner Product

Parameter 252: Enable/Disable Lock Configuration

This parameter is used to enable/disable Lock all configuration parameters.(0 =disable, 1 = enable)
Size: 1 Byte, Default Value: 0

Setting Description
0 All configuration parameters are configurable.
1 All configuration parameters are not configurable (Locked).

Parameter 255: Reset to default factory setting

This parameter is used to reset product to default factory setting. (There are just 2 values can be used).
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.
1 Resets all configuration parameters to default setting.

Parameter 3: Current Overload Protection

This parameter is used for the overload protection, which means the load will be disconnected after 5 seconds when the current more than 39.5A.
Size: 1 Byte, Default Value: 0

Setting Description
0 Overload Protection Disabled
1 Overload Protection is Enabled

Parameter 80: Enable/Disable to send notifications to associated devices to associated devices.

This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Smart Switch Gen5s load is changed. (0=Send nothing, 1=Send hail CC, 2=Send basic report CC).
Size: 1 Byte, Default Value: 0

Setting Description
0 Send Nothing (Disabled)
1 Send HAIL Command
2 Send BASIC Report Command

Parameter 90: Enable/Disable the function of parameter 91 and 92.

This parameter is used to Enable/Disable the function of parameter 91 and 92 (1=Enabled, 0=Disabled).
Size: 1 Byte, Default Value: 1

Setting Description
0 Configuration Parameters 91 and 92 are Disabled
1 Configuration Parameters 91 and 92 are Enabled

Parameter 91: Induce an automatic report

This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 32767 The threshold can be set from 0 to 32767 watt.

Parameter 92: Induce an automatic report

This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The threshold can be set from 0 to 100 percent.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 78 FW: 3.26
Z-Wave Version 6.51.01
Certification ID ZC10-14090014
Z-Wave Product Id 0x0086.0x0103.0x004E
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch