Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
N/A



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeon Labs Heavy Duty Smart Switch is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 40A current of resister loads. It also acts as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary listening Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.

Reset to factory default Press and hold the Z-Wave button for 20 seconds and then release.
Inclusion N/A
Exclusion N/A
NIF XXXNIF
Wakeup N/A
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.
2 5 When the Heavy Duty Smart Switch Gen5 receives the following commands, it will forward the commands to all node IDs (in Group 2).The command will be sent via multicast (if there are more than 2 Node IDs) or single-cast (if there is only one Node ID). Commands: Basic Set, Switch Binary Set, Scene Activation Set.

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

Turn the primary controller of Z-Wave network into exclusion mode, short press the products Z-Wave button.

Configuration Parameters

Parameter 100: Set parameter 101~103 to default.

This parameter is used to restore the parameter 101, 102 and 103 to default setting.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 When value==1, parameters 101 ~103 will be restored to default setting.When value==0, it will not restore any parameter.

Parameter 101: to set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 1 (The possible values as below).
Size: 4 Byte, Default Value: 4

Setting Description
0 - 15 When value==1, which means the Voltage report is configured to be sent in Report Group 1. When value==2, which means the Current report is configured to be sent in Report Group 1. When value==4, which means the Wattage report is configured to be sent in Report Group 1. When value==8, which means the KWH report is configured to be sent in Report Group 1. When value==15, which means the Voltage , Current , Wattageand KWH report are all configured to be sent in Report Group 1. The other values will be reserved.

Parameter 102: to set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 2 (The possible values as below).
Size: 4 Byte, Default Value: 8

Setting Description
0 - 15 When value==1, which means the Voltage report is configured to be sent in Report Group 2. When value==2, which means the Current report is configured to be sent in Report Group 2. When value==4, which means the Wattage report is configured to be sent in Report Group 2. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattageand KWH report are all configured to be sent in Report Group 2. The other values will be reserved.

Parameter 103: to set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 3 (The possible values as below).
Size: 4 Byte, Default Value: 0

Setting Description
0 - 15 When value==1, which means the Voltage report is configured to be sent in Report Group 3. When value==2, which means the Current report is configured to be sent in Report Group 3. When value==4, which means the Wattage report is configured to be sent in Report Group 3. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattageand KWH report are all configured to be sent in Report Group 3. The other values will be reserved.

Parameter 110: Set parameter 111~113 to default.

This parameter is used to restore the parameter 111, 112 and 113 to default setting.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 When value==1, parameters 111 ~113 will be restored to default setting.

Parameter 111: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 1.(The unit of time is second).
Size: 4 Byte, Default Value: 5

Setting Description
0 - 268435456 You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.

Parameter 112: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 2.(The unit of time is second).
Size: 4 Byte, Default Value: 120

Setting Description
0 - 268435456 You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.

Parameter 113: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 3.(The unit of time is second).
Size: 4 Byte, Default Value: 120

Setting Description
0 - 268435456 You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.

Parameter 200: PartnerID

This parameter is used to configure the partner ID.0== Aeon Labs Standard Product,1~255== others.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 There are 255 different partners can be configured.

Parameter 252: Enable/Disable Lock Configuration

This parameter is used to Enable/Disable Lock all configuration parameters.(0 =disable, 1 = enable)
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 When value==0, all configuration parameters are configurable. When value==1, all configuration parameters are not configurable.(Locked).

Parameter 255: Reset to default factory setting

This parameter is used to reset product to default factory setting.(There are just 2 values can be used)
Size: 4 Byte, Default Value: 0

Setting Description
0 - 1431655765 When value==1431655765, it will reset the product to default factory setting and be excluded from Z-wave network. When value==1, it only will reset the all configuration parameters to default setting. The other values will be reserved.

Parameter 3: Current Overload Protection

This parameter is used for the overload protection, which means the load will be disconnected after 5 seconds when the current more than 39.5A.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0=disabled, 1=enabled

Parameter 80: Enable/Disable to send notifications to associated devices to associated devices

This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Heavy Duty Smart Switch Gen5s load is changed. (0=send nothing, 1=send hail CC, 2=send basic CC report).
Size: 1 Byte, Default Value: 0

Setting Description
0 - 2 (0=nothing, 1=hail CC, 2=basic CC report

Parameter 90: Enable/Disable the function of parameter 91 and 92

This parameter is used to Enable/Disable the function of parameter 91 and 92 below (1=Enabled, 0=Disabled).
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0=disabled, 1=enabled

Parameter 91: Induce an automatic report

This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 60000 The threshold can be set from 0 to 60000 watt.

Parameter 92: Induce an automatic report

This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The threshold can be set from 0 to 100 percent.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 78 FW: 3.26
Z-Wave Version 6.51.00
Certification ID ZC10-14060004
Z-Wave Product Id 0x0086.0x0103.0x004E
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch