Quickstart

This is a Remote Control - Multi Purpose for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Short press the Learn button on the back of the Key Fob.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Key Fob Gen5 is a fully functional Z-wave remote controller, which can include, exclude and control the other Z-Wave certified devices.It also can be acted a secondary controller in a network.It is a four buttons design. You can use each button to control your homes Z-Wave devices and build a Z-Wave network for them. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.

Reset to factory default Use this procedure only in the event that the primary controller is missing or otherwise inoperable.Press and hold the Mode button and Learn button for 20 seconds and then release.
Inclusion Short press the Learn button on the back of the Key Fob.
Exclusion Short press the Learn button on the back of the Key Fob.
NIF XXXNIF
Wakeup Press and hold the "Learn" for 3 seconds will trigger sending the Wake up notification command.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the Key Fob is in Scene Mode, pressing the control button, which will send the corresponding Scene id to the associated nodes.

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

Short press the Include button on the Key Fob, it will go into inclusion state and its blue LED will blink slowly to wait including other slave Z-Wave devices.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

Short press the Exclude button on the Key Fob, it will go into exclusion state and its red LED will blink slowly to wait excluding other slave Z-Wave devices from its network.

Configuration Parameters

Parameter 250: Switching Group mode or Scene mode.

This parameter is used to configure that the current mode is Group Mode or Scene Mode. (0== Group Mode, 1== Scene Mode).
Size: 1 Byte, Default Value: 0

Setting Description
0 Set the current mode to Group Mode.
1 Set the current mode to Scene Mode.

Parameter 255: Reset the configuration parameter to default factory setting

This parameter is used to reset all configuration parameter to default factory setting.
Size: 1 Byte, Default Value: 0

Setting Description
1 Resets all configuration parameters to default setting.

Technical Data

Hardware Platform ZM5202
Device Type Remote Control - Multi Purpose
Network Operation Portable Controller
Firmware Version HW: 58 FW: 1.03
Z-Wave Version 6.51.00
Certification ID ZC10-14120003
Z-Wave Product Id 0x0086.0x0101.0x0058
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoRemote Control - Multi Purpose