Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Aeotec by Aeon Labs Recessed Door Sensor Gen5 is a door sensor that can detect the state of the door's open/close. It will report the door state to your controller/ gateway/associated nodes in real time when the state of your door has a change. Its a security Z-Wave device that supports security encryption. Also it supports the Over the Air Firmware Updating that allows you wirelessly update its firmware if needs. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.

Reset to factory default Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion N/A
Exclusion N/A
NIF XXXNIF
Wakeup Press and hold the Z-Wave button for 5 seconds will trigger sending the Wake up notification command and then keep waking up for 10 seconds after release the Z-Wave button.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.The Basic Set CC or Sensor Binary report CC will be sent to the associated nodes in Group 1.

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find in the back of the product.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

Turn the primary controller of Z-Wave network into exclusion mode, short press the products Z-Wave button that you can find in back of the product.

Configuration Parameters

Parameter 1: Which value of the Sensor Binary Report will be sent when the magnet switch to open/close.

This parameter is used to set the Sensor binary report value when the magnet switch to open/close.
Size: 1 Byte, Default Value: 0

Setting Description
0 When the magnet switch to open, Sensor Binary Report=0xFF. When the magnet switch to close, Sensor Binary Report=0x00.
1 When the magnet switch to open, Sensor Binary Report=0x00. When the magnet switch to close, Sensor Binary Report=0xFF.

Parameter 101: Enable/disable the function of low battery checking

This parameter is used to configure to enable/disable the function of low battery checking.(00==Disable, 1==Enable).
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable low battery checking.
1 Enable low battery checking.

Parameter 111: The interval time of low battery checking.

This parameter is used to configure the interval time of low battery checking.Note: 1. The minimum unit of interval time is 4 minutes(240). If the value is set to 1 minute, the interval time will be 4 minutes. The same is if the value is set to 7 minutes, the interval time will be 8 minutes. 2. The possible values are unsigned value, so its range is 0 to 2147483647.
Size: 4 Byte, Default Value: 86640

Setting Description
0 - 2147483647 The range of interval time is 0 to 2147483647.

Parameter 121: To set which command will be sent to the associated nodes when the magnet switch is triggered.

This parameter is used to set which command will be sent to the associated nodes when the magnet switch is triggered.
Size: 4 Byte, Default Value: 256

Setting Description
16 Send Sensor Binary Report to associated nodes when magnet switch is triggered.
256 Send Basic Set to associated nodes when magnet switch is triggered.
272 Send the Sensor Binary Report and Basic Set to associated nodes when magnet switch is triggered.

Parameter 252: Enable/disable all configuration parameters to be locked

This parameter is used to enable/disable all configuration parameters to be locked.(0 =disable, 1 = enable)
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable all configuration parameters to be locked.
1 Enable all configuration parameters to be locked.

Parameter 254: Device Tag

This parameter is used to set the device tag.Note: The possible values are unsigned value, its range is 0 to 65535.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 The range of device tag is 65535.

Parameter 3: Which value of the Basic Set will be sent when the magnet switch to open/close.

This parameter is used to set the Basic Set value when the magnet switch to open/close.
Size: 1 Byte, Default Value: 0

Setting Description
0 When the magnet switch to open, Basic Set=0xFF. When the magnet switch to close, Basic Set=0x00.
1 When the magnet switch to open, Basic Set=0x00. When the magnet switch to close, Basic Set=0xFF.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 59 FW: 1.13
Z-Wave Version 6.51.01
Certification ID ZC10-14120008
Z-Wave Product Id 0x0086.0x0102.0x0059
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor