Aeon Labs Home Energy Meter Gen5 is a Z-Wave device that can monitor the total amount of electricity of your home. It can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway). In near real-time youll have a full understanding of how much electricity you use and when you use it.Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world.
Reset to factory default | Press and hold the Action button that you can find on the product's housing for 10 seconds and then release. This procedure should only be used when the primary controller is inoperable. |
Inclusion | N/A |
Exclusion | N/A |
NIF | XXXNIF |
Wakeup | N/A |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.Automatic Reports will be sent to the associated nodes in association group 1. |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.
This parameter is used to induce an automatic report (Channel 2) when the change of the current power is more/less than the threshold in percentage. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100 percent. |
This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 8 and instantaneous Watts is the value 2, so setting parameter 101 to a value of 10 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 2
Setting | Description |
---|---|
4 | Report Instantaneous Voltage of whole HEM. |
8 | Report Instantaneous Current (Amperes) of whole HEM. |
2 | Report Instantaneous Watts of whole HEM. |
1 | Report Accumulated kWh of whole HEM. |
256 | Report Instantaneous Watts of Channel 1. |
768 | Report Instantaneous Watts of Channel 2. |
2048 | Report Accumulated kWh of Channel 1. |
4096 | Report Accumulated kWh of Channel 2. |
65536 | Report Instantaneous Voltage of Channel 1. |
196608 | Report Instantaneous Voltage of Channel 2. |
524288 | Report Instantaneous Current (Amperes) of Channel 1. |
1048576 | Report Instantaneous Current (Amperes) of Channel 2. |
This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 8 and instantaneous Watts is the value 2, so setting parameter 102 to a value of 10 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Report Accumulated kWh of whole HEM. |
2 | Report Instantaneous Watts of whole HEM. |
4 | Report Instantaneous Voltage of whole HEM. |
8 | Report Instantaneous Current (Amperes) of whole HEM. |
256 | Report Instantaneous Watts of Channel 1. |
768 | Report Instantaneous Watts of Channel 2. |
2048 | Report Accumulated kWh of Channel 1. |
4096 | Report Accumulated kWh of Channel 2. |
65536 | Report Instantaneous Voltage of Channel 1. |
196608 | Report Instantaneous Voltage of Channel 2. |
524288 | Report Instantaneous Current (Amperes) of Channel 1. |
1048576 | Report Instantaneous Current (Amperes) of Channel 2. |
This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 8 and instantaneous Watts is the value 2, so setting parameter 103 to a value of 10 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Report Accumulated kWh of whole HEM. |
2 | Report Instantaneous Watts of whole HEM. |
4 | Report Instantaneous Voltage of whole HEM. |
256 | Report Instantaneous Watts of Channel 1. |
768 | Report Instantaneous Watts of Channel 2. |
2048 | Report Accumulated kWh of Channel 1. |
4096 | Report Accumulated kWh of Channel 2. |
65536 | Report Instantaneous Voltage of Channel 1. |
196608 | Report Instantaneous Voltage of Channel 2. |
524288 | Report Instantaneous Current (Amperes) of Channel 1. |
1048576 | Report Instantaneous Current (Amperes) of Channel 2. |
8 | Report Instantaneous Current (Amperes) of whole HEM. |
This parameter is used to set the interval time of sending report in Report Group 1. (The unit of time is second). Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used to set the interval time of sending report in Report Group 2. (The unit of time is second). Size: 4 Byte, Default Value: 120
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used to set the interval time of sending report in Report Group 3. (The unit of time is second). Size: 4 Byte, Default Value: 120
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
Enable /disable reporting CRC-16 Encapsulation Command. (0 = disable, 1 = enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable CRC-16 Encapsulation. |
1 | Enable CRC-16 Encapsulation. |
This parameter is used to configure the energy detection mode when the parameter 101~103 have been configured:0 = report Wattage and the absolute KWH value;1 = report positive/negative Wattage and the algebraic sum KWH value;2 = report positive/negative Wattage and the positive KWH value (consuming electricity);3 = report positive/negative Wattage and the negative KWH value (generating electricity). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | report positive/negative Wattage and the algebraic sum KWH value; |
0 | report Wattage and the absolute KWH value; |
2 | report positive/negative Wattage and the positive KWH value (consuming electricity); |
3 | report positive/negative Wattage and the negative KWH value (generating electricity). |
This parameter is used to configure the partner ID. (0== Aeon Labs Standard Product, 1~255== others). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Aeon Labs Standard Product |
1 - 255 | Partner ID of Partner Product |
This parameter is used to enable/disable Lock all configuration parameters.(0 =disable, 1 = enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | All configuration parameters are configurable. |
1 | All configuration parameters are not configurable (Locked). |
This parameter is used to reset product to default factory setting. (There are just 2 values can be used). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. |
1 | Resets all configuration parameters to default setting. |
This parameter is used to enable/disable the function of parameter 4 and 10.(0 == disable, 1 == enable) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable the function of parameter 4 and 11. |
1 | Enable the function of parameter 4 and 11. |
This parameter is used to induce an automatic report (total wattage) when the change of the current power is more/less than the threshold in wattage. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
This parameter is used to induce an automatic report (Channel 1) when the change of the power is more/less than the threshold in wattage. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
This parameter is used to induce an automatic report (Channel 2) when the change of the power is more/less than the threshold in wattage. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
This parameter is used to induce an automatic report (total wattage) when the change of the current power is more/less than the threshold in percentage. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100 percent. |
This parameter is used to induce an automatic report (Channel 1) when the change of the current power is more/less than the threshold in percentage. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100 percent. |
Hardware Platform | ZM5202 |
Device Type | Sub Energy Meter |
Network Operation | Always On Slave |
Firmware Version | HW: 95 FW: 1.33 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-15040002 |
Z-Wave Product Id | 0x0086.0x0102.0x005F |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |