Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeon Labs Home Energy Meter Gen5 is a Z-Wave device that can monitor the total amount of electricity of your home. It can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway). In near real-time youll have a full understanding of how much electricity you use and when you use it.Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 10 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion N/A
Exclusion N/A
NIF XXXNIF
Wakeup N/A
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.Automatic Reports will be sent to the associated nodes in association group 1.

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.

Configuration Parameters

Parameter 10: Induce an automatic report of Channel 2.

This parameter is used to induce an automatic report (Channel 2) when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The threshold can be set from 0 to 100 percent.

Parameter 101: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 8 and instantaneous Watts is the value 2, so setting parameter 101 to a value of 10 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 2

Setting Description
4 Report Instantaneous Voltage of whole HEM.
8 Report Instantaneous Current (Amperes) of whole HEM.
2 Report Instantaneous Watts of whole HEM.
1 Report Accumulated kWh of whole HEM.
256 Report Instantaneous Watts of Channel 1.
768 Report Instantaneous Watts of Channel 2.
2048 Report Accumulated kWh of Channel 1.
4096 Report Accumulated kWh of Channel 2.
65536 Report Instantaneous Voltage of Channel 1.
196608 Report Instantaneous Voltage of Channel 2.
524288 Report Instantaneous Current (Amperes) of Channel 1.
1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter 102: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 8 and instantaneous Watts is the value 2, so setting parameter 102 to a value of 10 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 1

Setting Description
1 Report Accumulated kWh of whole HEM.
2 Report Instantaneous Watts of whole HEM.
4 Report Instantaneous Voltage of whole HEM.
8 Report Instantaneous Current (Amperes) of whole HEM.
256 Report Instantaneous Watts of Channel 1.
768 Report Instantaneous Watts of Channel 2.
2048 Report Accumulated kWh of Channel 1.
4096 Report Accumulated kWh of Channel 2.
65536 Report Instantaneous Voltage of Channel 1.
196608 Report Instantaneous Voltage of Channel 2.
524288 Report Instantaneous Current (Amperes) of Channel 1.
1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter 103: To set which report need to be sent.

This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 8 and instantaneous Watts is the value 2, so setting parameter 103 to a value of 10 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 0

Setting Description
1 Report Accumulated kWh of whole HEM.
2 Report Instantaneous Watts of whole HEM.
4 Report Instantaneous Voltage of whole HEM.
256 Report Instantaneous Watts of Channel 1.
768 Report Instantaneous Watts of Channel 2.
2048 Report Accumulated kWh of Channel 1.
4096 Report Accumulated kWh of Channel 2.
65536 Report Instantaneous Voltage of Channel 1.
196608 Report Instantaneous Voltage of Channel 2.
524288 Report Instantaneous Current (Amperes) of Channel 1.
1048576 Report Instantaneous Current (Amperes) of Channel 2.
8 Report Instantaneous Current (Amperes) of whole HEM.

Parameter 111: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 1. (The unit of time is second).
Size: 4 Byte, Default Value: 60

Setting Description
0 - 268435456 Interval Seconds

Parameter 112: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 2. (The unit of time is second).
Size: 4 Byte, Default Value: 120

Setting Description
0 - 268435456 Interval Seconds

Parameter 113: Set the interval time of sending report.

This parameter is used to set the interval time of sending report in Report Group 3. (The unit of time is second).
Size: 4 Byte, Default Value: 120

Setting Description
0 - 268435456 Interval Seconds

Parameter 13: Enable /disable CRC-16 Encapsulation.

Enable /disable reporting CRC-16 Encapsulation Command. (0 = disable, 1 = enable)
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable CRC-16 Encapsulation.
1 Enable CRC-16 Encapsulation.

Parameter 2: Energy detection mode configuration.

This parameter is used to configure the energy detection mode when the parameter 101~103 have been configured:0 = report Wattage and the absolute KWH value;1 = report positive/negative Wattage and the algebraic sum KWH value;2 = report positive/negative Wattage and the positive KWH value (consuming electricity);3 = report positive/negative Wattage and the negative KWH value (generating electricity).
Size: 1 Byte, Default Value: 0

Setting Description
1 report positive/negative Wattage and the algebraic sum KWH value;
0 report Wattage and the absolute KWH value;
2 report positive/negative Wattage and the positive KWH value (consuming electricity);
3 report positive/negative Wattage and the negative KWH value (generating electricity).

Parameter 200: Partner ID

This parameter is used to configure the partner ID. (0== Aeon Labs Standard Product, 1~255== others).
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 255 Partner ID of Partner Product

Parameter 252: Enable/Disable Lock Configuration

This parameter is used to enable/disable Lock all configuration parameters.(0 =disable, 1 = enable)
Size: 1 Byte, Default Value: 0

Setting Description
0 All configuration parameters are configurable.
1 All configuration parameters are not configurable (Locked).

Parameter 255: Reset to default factory setting

This parameter is used to reset product to default factory setting. (There are just 2 values can be used).
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.
1 Resets all configuration parameters to default setting.

Parameter 3: Enable/Disable the function of parameter 4 and 11.

This parameter is used to enable/disable the function of parameter 4 and 10.(0 == disable, 1 == enable)
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable the function of parameter 4 and 11.
1 Enable the function of parameter 4 and 11.

Parameter 4: Induce a automatic report of whole HEM.

This parameter is used to induce an automatic report (total wattage) when the change of the current power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 32767 The threshold can be set from 0 to 32767 watt.

Parameter 5: Induce a automatic report of Channel 1.

This parameter is used to induce an automatic report (Channel 1) when the change of the power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 32767 The threshold can be set from 0 to 32767 watt.

Parameter 6: Induce an automatic report of Channel 2.

This parameter is used to induce an automatic report (Channel 2) when the change of the power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 32767 The threshold can be set from 0 to 32767 watt.

Parameter 8: Induce an automatic report of whole HEM.

This parameter is used to induce an automatic report (total wattage) when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The threshold can be set from 0 to 100 percent.

Parameter 9: Induce an automatic report of Channel 1.

This parameter is used to induce an automatic report (Channel 1) when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The threshold can be set from 0 to 100 percent.

Technical Data

Hardware Platform ZM5202
Device Type Sub Energy Meter
Network Operation Always On Slave
Firmware Version HW: 95 FW: 1.33
Z-Wave Version 6.51.02
Certification ID ZC10-15040002
Z-Wave Product Id 0x0086.0x0102.0x005F
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoSub Energy Meter