This is a
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec Smart Switch 6 is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour.The Plug is also a security Z-wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.The Hial CC and Basic Report CC (configured by parameter 80) can be sent to the associatd nodes in this group. |
2 | 5 | Forward the Basic Set, Switch Binary Set to associated nodes in Group 2 when the Plug receives the Basic Set, Switch Binary Set commands from the main controller. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
To set which report would be sent in Report group 1 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which report would be sent in Report group 2 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which report would be sent in Report group 3 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
Set the time interval of sending Report Size: 4 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Set the time interval of sending Report Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Set the time interval of sending Report Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Configure the output load status after re-power on Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The last status before the power outage. |
1 | Always on |
2 | Always off |
PartnerID Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Aeon Labs Standard Product |
1 - 127 | Others |
Enable/disable Configuration Locked Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Device Tag Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | Device Tag |
Reset the Smart Switch 6 to factory default. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset all configuration parameters to default. |
1431655765 | Reset the Smart Switch to factory default |
Current Overload Protection. Output load will be closed after 2 minutes if the current overruns (US: 16.5A, AU: 10.5A, EU: 14A). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
Set the RGB LEDs color for testing. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Blue color value |
256 - 65535 | Green color value |
65536 - 16711680 | Red color value |
To set which report would be sent in Report group 1 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which report would be sent in Report group 2 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Nothing |
1 | Hail CC |
2 | Basic Report CC |
Configure the state of LED when it is in Energy mode, Momentary indicate mode or Night light mode. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Energy mode. The LED will follow the status (on/off). |
1 | Momentary indicate mode. When the state of Switchs load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. |
2 | Night light mode. The LED will remain the state that is set via the Multilevel Switch Set CC or Color Switch Set CC. |
Configure the RGB value when it is in Night light mode. Size: 4 Byte, Default Value: 1774619
Setting | Description |
---|---|
0 - 255 | Blue color value |
256 - 65535 | Green color value |
65536 - 16711680 | Red color value |
Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/Momentary indicate mode. Size: 4 Byte, Default Value: 3289650
Setting | Description |
---|---|
0 - 100 | The brightness of Red color |
256 - 356 | The brightness of Yellow color |
65536 - 65636 | The brightness of Green color |
Enable/disable the parameter 91 and 92. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
The value here represents minimum change in wattage (in terms of wattage) to induce a Meter Report Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
The value here represents minimum change in wattage percent (in terms of percentage) to induce a Meter Report Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100%. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 96 FW: 1.01 |
Z-Wave Version | 6.51.10 |
Certification ID | ZC10-18106279 |
Z-Wave Product Id | 0x0086.0x0203.0x0060 |
Firmware Updatable | Updatable by Consumer by RF |
Supported Meter Type | Electric Energy |
Electric Load Type | Dimmable LEDELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |