This is a
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Aeotec Smart Switch 6 is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour.The Plug is also a security Z-wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Reset to factory default | Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. |
Inclusion | Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing. |
Exclusion | Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.The Hial CC and Basic Report CC (configured by parameter 80) can be sent to the associatd nodes in this group. |
2 | 5 | Forward the Basic Set, Switch Binary Set to associated nodes in Group 2 when the Plug receives the Basic Set, Switch Binary Set commands from the main controller. |
To set which report would be sent in Report group 1 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which report would be sent in Report group 2 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which report would be sent in Report group 3 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
Set the time interval of sending Report Size: 4 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Set the time interval of sending Report Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Set the time interval of sending Report Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Configure the output load status after re-power on Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The last status before the power outage. |
1 | Always on |
2 | Always off |
PartnerID Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Aeon Labs Standard Product |
1 - 127 | Others |
Enable/disable Configuration Locked Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Device Tag Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | Device Tag |
Reset the Smart Switch 6 to factory default. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset all configuration parameters to default. |
1431655765 | Reset the Smart Switch to factory default |
Current Overload Protection. Output load will be closed after 2 minutes if the current overruns (US: 16.5A, AU: 10.5A, EU: 14A). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
Set the RGB LEDs color for testing. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Blue color value |
256 - 65535 | Green color value |
65536 - 16711680 | Red color value |
To set which report would be sent in Report group 1 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which report would be sent in Report group 2 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Nothing |
1 | Hail CC |
2 | Basic Report CC |
Configure the state of LED when it is in Energy mode, Momentary indicate mode or Night light mode. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Energy mode. The LED will follow the status (on/off). |
1 | Momentary indicate mode. When the state of Switchs load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. |
2 | Night light mode. The LED will remain the state that is set via the Multilevel Switch Set CC or Color Switch Set CC. |
Configure the RGB value when it is in Night light mode. Size: 4 Byte, Default Value: 1774619
Setting | Description |
---|---|
0 - 255 | Blue color value |
256 - 65535 | Green color value |
65536 - 16711680 | Red color value |
Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/Momentary indicate mode. Size: 4 Byte, Default Value: 3289650
Setting | Description |
---|---|
0 - 100 | The brightness of Red color |
256 - 356 | The brightness of Yellow color |
65536 - 65636 | The brightness of Green color |
Enable/disable the parameter 91 and 92. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
The value here represents minimum change in wattage (in terms of wattage) to induce a Meter Report Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
The value here represents minimum change in wattage percent (in terms of percentage) to induce a Meter Report Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100%. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 96 FW: 1.01 |
Z-Wave Version | 6.51.10 |
Certification ID | ZC10-18106279 |
Z-Wave Product Id | 0x0086.0x0203.0x0060 |
Firmware Updatable | Updatable by Consumer by RF |
Supported Meter Type | Electric Energy |
Electric Load Type | Dimmable LEDELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |