Quickstart

This is a secure Light Dimmer Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeotec Smart Dimmer 6 is a low-cost Z-Wave Dimmer plug-in module specifically used to enable Z-Wave command and control (on/off/dim) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour.The Smart Dimmer 6 is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus LifelineThe Basic Report CC and Hail CC (configured by parameter 80) can be sent to this association group.
2 5 The Basic Set and Switch Multilevel CC will be sent to the associated nodes in this group when the Smart Dimmer 6 receives the Basic Set or SwitchMultilevel CC from the main controller.

Configuration Parameters

Parameter 100: Set 101-103 to default.

Set 101-103 to default value.
Size: 1 Byte, Default Value: 0

Setting Description
1 Set 101-103 to default value.

Parameter 101: To set which report needs to be sent in Report group 1

To set which report needs to be sent in Report group 1
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report for Voltage
2 Send Meter Report for Current
4 Send Meter Report for Watt
8 Send Meter Report for kWh

Parameter 102: To set which report needs to be sent in Report group 2

To set which report needs to be sent in Report group 2
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report for Voltage
2 Send Meter Report for Current
4 Send Meter Report for Watt
8 Send Meter Report for kWh

Parameter 103: To set which report needs to be sent in Report group 3

To set which report needs to be sent in Report group 3
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report for Voltage
2 Send Meter Report for Current
4 Send Meter Report for Watt
8 Send Meter Report for kWh

Parameter 110: Set 111-113 to default.

Set 111-113 to default.
Size: 1 Byte, Default Value: 0

Setting Description
1 Set 111-113 to default.

Parameter 111: The time interval of sending Report group 1

The time interval of sending Report group 1
Size: 4 Byte, Default Value: 3

Setting Description
1 - 2147483647 the available range is 1 to 2147483647 seconds

Parameter 112: The time interval of sending Report group 2

The time interval of sending Report group 2
Size: 4 Byte, Default Value: 600

Setting Description
1 - 2147483647 the available range is 1 to 2147483647 seconds

Parameter 113: The time interval of sending Report group 3

The time interval of sending Report group 3
Size: 4 Byte, Default Value: 600

Setting Description
1 - 2147483647 the available range is 1 to 2147483647 seconds

Parameter 2: Make Dimmer blink

This parameter is used to set the Smart Dimmer to start the blinking state.
Size: 2 Byte, Default Value: 3850

Setting Description
1 - 255 Specify the cycle of On/Off.
256 - 32512 Specify the time of Dimmer blinking.

Parameter 20: Configure the output load status after re-power on

Configure the output load status after re-power on.
Size: 1 Byte, Default Value: 0

Setting Description
0 Last status.
1 Always On
2 Always Off

Parameter 200: PartnerID

Set the PartnerID
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 255 Others

Parameter 252: Enable/disable the Configuration parameters to be Locked.

Enable/disable the Configuration parameters to be Locked.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 254: Device Tag

Set the Device tag for Smart Dimmer 6
Size: 2 Byte, Default Value: 0

Setting Description
1 - 32767 The available range is 1 to 32767.

Parameter 255: Reset the Smart Dimmer 6

Reset the Smart Dimmer 6
Size: 4 Byte, Default Value: 0

Setting Description
0 Reset all configuration parameters to factory default setting
1431655765 Reset Smart Dimmer 6 to factory default setting and exclude from the network

Parameter 3: Current overload protection

When this parameter is enabled,the output Load will be turned off automatically when the Current overrun 2.6A and the time more than 2 minutes.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 33: Set the RGB LED color value for factory testing.

Set the RGB LED color value for factory testing.Note: this is a Set-only parameter.
Size: 4 Byte, Default Value: 0

Setting Description
1 - 255 Blue color value
256 - 65280 Green color value
65536 - 16711680 Red color value

Parameter 80: To set which notification report can be sent to associated Nodes in association Group 1

To set which notification report can be sent to associated Nodes in association Group 1 when the state of Smart Dimmers load is changed
Size: 1 Byte, Default Value: 0

Setting Description
0 Send Nothing
1 Send Hail CC
2 Send Basic Report CC
3 Send Hail CC when using Action Button to change the output load state.

Parameter 81: Configure the state of LED

Configure the state of LED when it is in Energy mode, Momentary indicate mode or N ight light mode.
Size: 1 Byte, Default Value: 0

Setting Description
0 Energy mode, the LED will follow the status (on/off) of its load
1 Momentary indicate mode, when the state of Dimmers load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action.
2 Night light mode.

Parameter 83: Configure the RGB value when it is in Night light mode.

Configure the RGB value when it is in Night light mode.
Size: 4 Byte, Default Value: 1774619

Setting Description
1 - 255 Blue color value
256 - 65280 Green color value
65536 - 16711680 Red color value

Parameter 84: Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode.

Configure the brightness level of RGB LED (0%-99%) when it is in Energy Mode/momentary indicate mode.
Size: 4 Byte, Default Value: 3289650

Setting Description
0 - 99 The brightness level of Green color
256 - 355 The brightness level of Yellow color
65536 - 65635 The brightness level of Red color

Parameter 90: Enable or disable the parameter 91 and 92

Enable or disable the parameter 91 and 92.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 91: Minimum change in wattage (in terms of wattage) to induce a Meter Report

The value here represents minimum change in wattage (in terms of wattage) to induce a Meter Report.
Size: 2 Byte, Default Value: 25

Setting Description
0 - 60000 The available range is 0 to 60000

Parameter 92: Minimum change in wattage percent (in terms of percentage) to induce a Meter Report

The value here represents minimum change in wattage percent (in terms of percentage) to induce a Meter Report.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 100 The available range is 0 to 100%

Technical Data

Hardware Platform ZM5101
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 99 FW: 1.11
Z-Wave Version 6.51.09
Certification ID ZC10-17035455
Z-Wave Product Id 0x0086.0x0103.0x0063
Z-Wave Scene Type Scene
Electric Load Type Dimmable LEDIncandescent
Firmware Updatable Updatable by Consumer by RF
Color White
Supported Meter Type Electric Energy
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoLight Dimmer Switch